Search

3941 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3941 products
Crystallization bowl diam. 60 mm, pack.10/240 pcs
Crystallization bowl diam. 60 mm, pack.10/240 pcs
from 227 ₽
Designed for evaporation and recrystallization of chemicals. Made of TS glass according to GOST 21400-75.TU 4320-012-29508133-2009.
MiniMed
Suponevo
Produced in: Bryansk region
LT-DP Sensor Holder
LT-DP Sensor Holder
The spring holder for LT 300 or LT electronic thermometers allows you to simply and securely mount the temperature sensor on the walls of laboratory utensils so that it does not touch either its bottom or the wall. This allows temperature measurements to be carried out not only conveniently, but also correctly.
Produced in: Tomsk
Infrared analyzer INFRASKAN 4200
Infrared analyzer INFRASKAN 4200
1 supp.
The INFRASKAN 4200 analyzer has been tested at the D.I. Mendeleev VNIIM, entered into the unified State Register of measuring instruments under No. 83050-21. All manufactured devices undergo primary verification and have the appropriate certificate. Analyzes a wide range of quality indicators (protein, moisture, quantity and quality of gluten (IDC), fat/oil content, water absorption capacity, acid number, peroxide number, m.d. phosphorizing substances, etc.) Is calibrated to assess moisture and protein in whole grains (wheat, barley). The cuvette compartment for the analysis of bulk, liquid and pasty products allows to analyse liquid vegetable oils without the use of additional devices. The built-in whiteness module allows to determine the whiteness of the product simultaneously with other quality indicators (moisture, protein, amount of gluten). A wide spectral range (400-2500nm) provides measurement of the zonal reflection coefficient to determine the whiteness of flour in accordance with the GOST 26361-2013 methodology. It is possible to calculate the amino acid composition of feed components. To organize the work of analyzers in the ECANET network, the INFRASCAN-4200 analyzer can be used as a server for storing and transmitting data. The remote access mode allows to remotely update existing calibrations, install additional calibration models and develop new calibration models for new products, as well as make adjustments to technical settings if necessary.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Optical Transceiver SFP+ DAC
Optical Transceiver SFP+ DAC
SFP+ Direct Attach Cable manufactured by Optronic is a passive Twinax cable with a length of 1 to 5 meters, the operating data transfer rate is up to 10 Gbits. SFP+ DAC are compatible with Ethernet equipment of such brands as Cisco, Extreme, Juniper, HP, Dell, Force10, Huawei, Dlink, etc.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K3-EDTA and separation gel, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K3-EDTA and separation gel, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
from 1 250 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Liquid low-temperature thermostat CRYO-VIS-T-07
Liquid low-temperature thermostat CRYO-VIS-T-07
Operating temperature range +10...+60 °C Five places for glass viscometers. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 20 l Overall dimensions 620x400x970 mm The open part of the bath is 240x170 mm Bath depth 300 mm The size of the viewing window is 205x260 mm Weight 60 kg Power consumption 3.5 kW
Produced in: Tomsk
LB-57164 Laboratory bath with 2 working baths
LB-57164 Laboratory bath with 2 working baths
It is designed for thermostating samples of natural and drinking water for organoleptic assessment of odor intensity in accordance with GOST R 57164 and for determining the odor of natural and treated wastewater in accordance with RD 52.24.496. A cooling heat exchanger installed in one of the working baths, when connected to a water supply or a flow cooler, allows you to maintain the temperature in this bath +20 ° C while the other working bath has a temperature of +60 ° C, which meets the requirements of GOST R 57164. The volume of the bath is 5 liters Overall dimensions 400x400x350 mm The open part of the bath is 295x145 mm Bath depth 110 mm Weight 12 kg Power consumption 2.5 kW
Produced in: Tomsk
Septa for Fischer titrators C20, C30, DL32, DL39
Septa for Fischer titrators C20, C30, DL32, DL39
from 3 600 ₽
Septa for titrators are made of fluorosiloxane rubber. The main difference between this material and traditional silicone is the presence of trifluoropropyl groups in the chain, which give fluorosiloxane rubber chemical resistance to solvents, fuels, oils, acids, alkalis, and a number of oxidants, as well as a wide operating temperature range from -60 to +200℃. Characteristics of the septa produced by us for the L 51108740 titrator: Diameter -12 mm Thickness - 2 mm Color - white Density -1.50 ± 0.05 g/cm3 Hardness -60- 70 units. Shore A
LABEX
Saint Petersburg
Immitance meter E7-30
Immitance meter E7-30
Technical specifications: Wide frequency range 25 Hz–3 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.005 – 1) V RS-232C, USB 2.0 interfaces Mathematical processing of measurements Dimensions, weight: 134x270x320 mm, 4 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Smart air probe L=1000 mm SSV.1000P with built-in flash memory
Smart air probe L=1000 mm SSV.1000P with built-in flash memory
from 14 214 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=1000 mm SSV.1000P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.1000P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.1000P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
“SP-10 Lab” ultrasonic bath by SpetsmashSonic
“SP-10 Lab” ultrasonic bath by SpetsmashSonic
Bath name: UZK-10; Body overall dimensions, mm: 400x265x390; Working capacity size: 300x240x200; Basket size: 225x175x150; Volume, l: 10; Power, W: 570; Ultrasound power, W: 260;
Produced in: voronezh
Universal frequency meter Ch3-86A
Universal frequency meter Ch3-86A
The frequency meter is capable of operating both independently and as part of automated measuring systems with an interface such as USB, RS-232 or IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal and video pulse signals (input A) 0.005 Hz - 100 MHz Frequency of sinusoidal and video pulse signals (input to) 0.01 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (0.6 - 17.85) GHz Pulse duration 10 ns - 10000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from 0 to 10000 s The frequency ratio of the two signals is up to 109 The average value of the carrier frequency of the pulse-modulated (IM) signal (input D) (0.6 - 17.85) GHz Frequency measurement resolution 2x10-10 s/Rng Phase difference of two synchronous sinusoidal signals from minus 180° to 180° Measurement error of the phase difference of two synchronous sinusoidal signals ± 0.36° (from 1 kHz to 1 MHz)±3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 30 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •inputs C, D (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz; 220 V, 400 Hz Power consumption, no more than 50 VA Overall dimensions, mm 229x136x435.5 Weight, not more than 7.5 kg
Produced in: Moscow