Search

3939 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 549
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3939 products
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 120.74.230 KG
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 120.74.230 KG
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 304 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – tempered glass in an aluminum frame on the top panel: 4 anti-explosion valves LED dust- and moisture-proof lamp (2x10W IP65) is separated from the workspace by tempered glass thickness of 4mm flange d=250mm (distance from rear panel to the center of the flange – 170mm) switching box with automatic emergency power off 16A easily removable exhaust visors 3 levels of exhaust on the rear panel: technological hole d = 60mm with a plastic plug counterweights are placed in the front pillars-pylons and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather front pillars - aluminum profile painted with powder paint (RAL 7035/RAL 5023) adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LB41 Laboratory bath
LB41 Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Three workstations with a diameter of 110 mm with five steel O-rings. Stamped steel bath with a volume of 8 liters and a depth of 60 mm. Bath volume 8 l Overall dimensions 385x370x265 mm The open part of the bath is 325x290 mm Bath depth 60 mm Weight 10 kg Power consumption 2.5 kW
Produced in: Tomsk
Monoblock liquid cooling unit MCHV-15
Monoblock liquid cooling unit MCHV-15
from 288 495 ₽
Designation MCHV-15 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 15 Required pump capacity, m3/h 3.3 Pressure loss in the heat exchanger, kRa 65
Produced in: Tula
Wide neck bottles LDPE (matte)
Wide neck bottles LDPE (matte)
from 20 ₽
Bottles are used to protect the basic properties of chemical, pharmaceutical and other liquid, paste-like, mixed fluid products. Designed for scientific research. Not intended for medical use. Bottle: low density polyethylene (LDPE). Cover: polypropylene (polypropylene copolymers). The addition of a nucleator (illuminator) is allowed for greater hardness (if necessary).
SkyGen
Moscow
Produced in: Vladimir
Vacuum drying cabinet with manual control SNVS-90/5
Vacuum drying cabinet with manual control SNVS-90/5
from 476 940 ₽
The drying cabinet with manual vacuum adjustment SNVS-90/5 (or SNVS-4,3.4,3.4.9/5) is designed for heat treatment of materials at temperatures up to 500 ° C with air access and in a vacuum controlled by manual valves.
Produced in: Tula
SHGS-1-SK SINGLE-SECTION LOCKER WITH BENCH
SHGS-1-SK SINGLE-SECTION LOCKER WITH BENCH
from 39 350 ₽
The locker is designed for storing clothes in the changing rooms of industrial enterprises, medical institutions, educational institutions and other facilities. The design is based on a painted aluminum profile. Doors and other locker elements are made of moisture-resistant HPL-plastic. The materials used ensure the strength and durability of the product, are not afraid of moisture, and are suitable for sanitization with disinfectants. Width - 400
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Wall-mounted high table LAB-PRO SPCv 90.80.90 TR-E16/23
Wall-mounted high table LAB-PRO SPCv 90.80.90 TR-E16/23
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with manual control SNVS-155/3.5
Vacuum drying cabinet with manual control SNVS-155/3.5
from 726 687 ₽
Vacuum drying cabinet model SNVS-155/3,5-I2-RT-N with a volume of 155 liters of special design with a chamber width of 630 mm., with manual vacuum adjustment from the back of the chamber for heat treatment at temperatures up to 350 degrees.
Produced in: Tula
Universal frequency meter Ch3-89
Universal frequency meter Ch3-89
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
Produced in: Moscow
Vacuum tube MiniMed with separation gel, 10 ml, 16×100 mm, red, PET, pack.100 pcs.
Vacuum tube MiniMed with separation gel, 10 ml, 16×100 mm, red, PET, pack.100 pcs.
from 984 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Circulation thermostat LT-224b
Circulation thermostat LT-224b
The LOIP LT-224b modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 24 The working fluid is water, water-glycerin mixture, silicone oil. Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 535x335x420 Weight, kg 14.2
LOIP
Saint Petersburg
Produced in: Saint Petersburg
CF Rotating Flanges
CF Rotating Flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan