Oxygen generator "Advans series"
Oxygen generator "Advans series"
An oxygen adsorption generator is a special equipment designed to produce gaseous oxygen from atmospheric air by short—cycle non-heating adsorption. The main components of the generator are: adsorbers (vessels operating under excessive pressure) filled with zeolite molecular sieve, pneumatic valves, automatic control system, shut-off and control valves and other control and measuring devices, and equipment. Oxygen concentration: 90-95% Capacity: 7-44 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Smart air probe L=150 mm SSV.150
Smart air probe L=150 mm SSV.150
from 9 960 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. The smart air probe L=150 mm SSV.150 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.150 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.150 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
VEGA ProVac 1500 high-vacuum turbomolecular pump
VEGA ProVac 1500 high-vacuum turbomolecular pump
The complex includes: VEGA ProVac 1500 turbomolecular high vacuum pump; frequency converter; set of mounting parts; operation manual. For connection to the pre-vacuum pumping system, the pump is equipped with an ISO-KF40 exhaust flange. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is vertical.
Produced in: Vladimir
Oxygen concentrator "Provita-1200M"
Oxygen concentrator "Provita-1200M"
Devices capable of generating oxygen have found the widest application in various fields of medicine. The equipment is also used in training centers, educational institutions and oxygen rooms. Medical oxygen concentrators make it possible to accelerate the recovery of patients suffering from cardiovascular diseases, chronic respiratory diseases, as well as other pathologies that make it difficult to saturate the blood with oxygen. This equipment is a mandatory equipment for anesthesiology and intensive care units. Oxygen concentrators demonstrate high efficiency in restorative treatment. Unlike oxygen sources, which use compressed gas, generators are characterized by high safety and efficiency Capacity: 1600 l/min 96.0 m3/h 127.7 kg/h Oxygen purity: 95 % Oxygen pressure: 4-5 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Nitrogen Purification Units BOV-1A
Nitrogen Purification Units BOV-1A
from 69 600 ₽
They are designed for purification of nitrogen (BOV-1A) and air (BOV-1) from hydrocarbons Technical specifications Maximum nitrogen inlet pressure is not more than 410± 5% kPa (4 ati) Maximum allowable nitrogen consumption is no more than 350 ml/min The concentration of hydrocarbons in terms of methane in the input nitrogen is not more than 0.0025 %(25 ppm) The concentration of hydrocarbons in nitrogen at the outlet of the device at maximum flow is not more than about 0.00001 % (0.1 ppm) Ready time after switching on at a flow rate not exceeding the maximum value is no more than 30 minutes Power consumption is not more than 50 VA Overall dimensions, (width x depth x height) are not more than 185x310x310 mm Weight is not more than 5.0 kg Working conditions: ambient temperature, °C, from +10 to +35 relative humidity of the surrounding air, %, no more, at 35 °C 80 Electric power supply from a single-phase AC network with a voltage of 220 +10% -15% and a frequency of 50 ± 1 Hz
Produced in: Moscow
Vacuum tube MiniMed with separating gel, 4 ml, 13×100 mm, red, glass, pack.100 pcs
Vacuum tube MiniMed with separating gel, 4 ml, 13×100 mm, red, glass, pack.100 pcs
from 1 257 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
MiniMed sterile tampon probe with a test tube with Ames transport medium with coal,TU 32.50.50-031-29508133-2019 , ind. pack./100 pcs./1000
MiniMed sterile tampon probe with a test tube with Ames transport medium with coal,TU 32.50.50-031-29508133-2019 , ind. pack./100 pcs./1000
from 2 100 ₽
The Ames transport environment is another modification of the basic Stewart transport environment. This medium is capable of supporting microorganisms such as Neisseria sp., Haemophius sp., Corynebacteria, Streptococci, Enterobacteriaceae, etc. for up to 3 days, however, cultivation during the first 24 hours gives the best results. Coal absorbs substances that are toxic to bacteria. The tampon probe is packed in a high-impact PP tube (12*150 mm). The test tube is provided with a label indicating: batch number, date of sterilization, expiration date, manufacturing company, supplier company, and also provides a place for applying information about the patient and the sample. The edge of the label is fastened with a stopper that closes the tube with a tampon - the label serves as the control of the first opening. Store at a temperature not lower than + 5 °C and not higher than + 25 °C.
MiniMed
Suponevo
Produced in: Bryansk region
Liquid thermostat THERMOTEST-300
Liquid thermostat THERMOTEST-300
The operating temperature range is +95...+300 °C. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C without the use of a leveling unit. Bath volume 14 l Overall dimensions 360x360x900 mm The open part of the bath is 90 mm Bath depth 520 mm Weight 35 kg Power consumption 2.2 kW
Produced in: Tomsk
Wall-mounted table LAB-1800 PT
Wall-mounted table LAB-1800 PT
EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP