Search

3949 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 552
    Names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3949 products
Laboratory Table of Gamma LAB Series
Laboratory Table of Gamma LAB Series
1 supp.
The laboratory tables are based on a strong metal frame covered with chemically resistant paint, which is adjustable in height from 740 to 860 mm and can withstand a load of up to 200 kg. The material of the countertops can be selected based on the tasks set. The tables in a standard set have a main shelf made of chipboard or plastic (HPL, HPL PLUS) and a socket block built into the right or left panel (5 sockets with grounding, 1 socket without grounding, a switch-off button), the main LED lighting is built into the upper horizontal bracket.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Laboratory table of Classic LAB series
Laboratory table of Classic LAB series
1 supp.
Laboratory tables of Classic LAB series are based on a strong metal frame covered with chemically resistant paint, which is adjustable in height from 650 to 900 mm and can withstand a load of up to 300 kg. The material of the countertops can be selected based on the tasks set.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Pulse DC power supply B5-71/5-PRO
Pulse DC power supply B5-71/5-PRO
1 supp.
Regulated switching power supplies with highly stable output characteristics Digital display of set and actual value, voltage and current (4 digits, LED) Electronic load switching on/off Protection against overload, short circuit, overheating and reverse polarity Low ripple output voltage less than 2mV Low ripple output current less than 5mA Minimum discreteness of setting output voltage and current 0.007/0.005 Operating modes: stabilization U and I, dynamic load RS-232 interface
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Model 130 Profilometer
Model 130 Profilometer
Measurement of roughness parameters Ra; Rz; Rmax; Rp; Rv; Rq; Sm; S; la; lq; tp; Lo; D; da; dq, etc., viewing the profilogram and measuring the size of inhomogeneities Tracing length: 0.5mm – 40 mm Measurement range according to Ra: 0.012 – 50mkm Degree of accuracy 1 (error 2%) Work inside the vestibule > 3mm
Produced in: Moscow, Zelenograd
Scanning probe microscope SMM-2000
Scanning probe microscope SMM-2000
Viewing and measuring grains and defects in the structure of materials, resolution to atoms (Nobel Prize in 1986), replacement of metal-graphic and electron microscopes Increase: from x2 thousand to x10 million. Measuring range: 0.2 nm to 30 microns All basic (STM, contact and vibro-AFM) modes, and more than 25 extras.modes
Produced in: Moscow, Zelenograd
Workplace of Classic series
Workplace of Classic series
1 supp.
When lining up, Classic series desktops fit snugly together, without forming cracks and gaps. The universal design of the table frame allows you to further equip the workplace with a suspended pedestal and other necessary equipment. Additionally, work tables of Classic series can be equipped with a number of modules: electrical and perforated panels, overhead and local lighting, shelves for equipment, hanging cabinets, corner tables, etc.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Workplace of Comfort series
Workplace of Comfort series
1 supp.
The universal design of the table frame allows you to equip the workplace with a hanging pedestal and other necessary equipment. Additionally, work tables of Comfort series can be equipped with a number of modules: a reinforcing bar, electrical and perforated panels, overhead and local lighting, shelves for equipment, hanging cabinets, corner tables.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
LBR-2 Laboratory
LBR-2 Laboratory
Scope of delivery of the laboratory: — viscometer VBR-2; — lever scales VRP-1M; — glass, 1000 ml; — pH strips, pH 1-14, 100 pcs./pack; — electronic stopwatch; — determination of the sand content.
Produced in: Krasnodar
Mains current indicator autonomous “STORK” EI3008
Mains current indicator autonomous “STORK” EI3008
Technical specifications The indicator provides the ability to measure current without breaking circuits at a height of up to 7.5 m from ground level. Power supply: two AAA elements of 1.5 V. Operating conditions: temperature from -10°C to +40°C, relative humidity 80% at +25 °C. Overall dimensions in the working position 6600x70x80 mm Overall dimensions in the stowed position (cover) 1700x100x70mm. Weight 2.5 g. As a measuring device, a digital multimeter with a memory function, semi-automatic selection of measurement limits is used. Measurement of alternating current up to 500 A with a measurement accuracy of 3%. Measurement of AC and DC voltage up to 600 V with a measurement accuracy of 2%; resistance measurement – up to 2.0 M ohms. Ringing of electrical circuits. Structurally, the indicator consists of four fiberglass rods articulated with each other using connectors. On the upper rod there is a detachable magnetic circuit covering the wire in which the current must be measured. On the lower rod there is a measuring device that records the current values. They are not subject to mandatory certification (they are not included in the “Nomenclature of products and services (works) for which mandatory certification is provided by legislative acts of the Russian Federation”. It was put into effect from 01.12.2002 by the resolution of the State Standard of the Russian Federation No. 64 dated 30.07.2002.)
Produced in: Krasnodar
The PKN-2 device
The PKN-2 device
The PKN-2 device is designed to determine the swelling coefficient of clays. Device indicators: Indicator division price, mm — ( 0.01 ) Working stroke of the indicator rod, mm — ( 11.5 ) Overall dimensions, mm — ( 60x85x415 ) Weight, kg — ( 0,7 )
Produced in: Krasnodar
Consistometer ZM-1003M
Consistometer ZM-1003M
The consistometer can be used in laboratories of grouting offices, drilling departments and oil-producing associations, as well as in laboratories of research organizations engaged in the development of formulations and research of grouting cements, mixtures and solutions for cementing wells. The consistometer can be transported to the place of testing cement mortars in compliance with the rules of transportation specified in the passport of the device, while no additional calibration is required. The consistometer works in conjunction with a personal computer, as well as in offline mode under the control of a microprocessor system. The pressure is set by a manual high-pressure pump by the operator. In the dialog mode, the operator sets the parameters necessary for testing grouting solutions. The test results can be transmitted via the USB interface to a personal computer for printing, archiving or processing by user programs. Technical specifications The range of determination of consistency is from 0 to 100 units of consistency (1e.k. = 1 Bc, Bc is a unit of consistency of Burden). The limit of the permissible reduced error in determining the consistency is ± 5% of the measurement range (100 E.K. = 100 Bc). The rotational speed of the measuring frame in cement mortar is (150 ±1) rpm. The heating range of the tested solutions is from the current temperature to 200 ° C. The limit of the permissible reduced error in determining the temperature is ± 1%. The range of the tested pressure is from the current, atmospheric, to 100 MPa. The limit of the permissible reduced error in determining the pressure in the autoclave is ± 2.5%. Operating conditions: ambient temperature – from +10 to +35 ° C; relative humidity up to 65% at 20 ° C and up to 80% at 27 ° C. The electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm. The electrical insulation between the electrical circuits and the housing under the conditions of clause 2.7. must withstand an alternating current voltage of 1.5 kV of a sinusoidal shape with a frequency of 50 Hz. Power supply of the installation: voltage: ≈ 220 V ±10%; the frequency of the supply network is 50 Hz; power consumption, no more than - 3 kW. Overall dimensions, not more than, mm: 750x400x1000; The average service life is at least 10 years. The mass of the consistometer is no more than 145 kg.
Produced in: Krasnodar
VBR-2 Viscometer
VBR-2 Viscometer
Indicators of the device: — the constant of the viscometer at a temperature of 20 + 5 0C, sec — ( 15 ). — absolute error of the viscometer constant, sec — ( +0.5 ). — measuring range, sec — (from 1 to 100 ). — diameter of the opening of the viscometer tube, mm — ( 5 +0.012 ). — length of the viscometer tube, mm — ( 100 -0.46 ). — capacity of the viscometer, ml — ( 700 +40 ). — measuring cup capacity, ml — ( 500 +5 ). In addition to the device Viscometer VBR-2, you can order a tripod.
Produced in: Krasnodar