Search

4044 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 527
    Names
    Loading...
  • 128
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 97
    Additional
    Loading...
View:
4044 products
Red DPSS Laser 655 nm KLM-655-x
Red DPSS Laser 655 nm KLM-655-x
DPSS lasers of the KLM-655/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet LAB-1600 ballscrews
Exhaust cabinet LAB-1600 ballscrews
Working surface: Porcelain stoneware (ceramic tile 300*300mm) Length, mm: 1632 Depth, mm: 925 Height, mm: 2100 equipment Working box the side and back panels are lined with a row of ceramic tiles to a height of 400mm the case is melamine with a thickness of 16mm lifting screen with the possibility of fixing at any height – organic acrylic glass with a thickness of 8mm, lifting 0–750mm, increases the height of the cabinet with a full lift by 430mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
GAS FLOW SHAPER
GAS FLOW SHAPER
The gas flow shaper (FGP) is designed to automate the old fleet of chromatographs of the LHM type, model-3700, "Color" series, etc. in terms of setting and regulating the flow and pressure of both the carrier gas and auxiliary gases. The FGP has a flexible structure and provides regulation of gas flows from two to four independent gas flow channels and up to three pressure channels. The gas pressure at the inlet is (0.4 ± 0.04) MPa. The operating flow ranges of the carrier gas are from 3 to 250 ml/min with a discreteness of 1 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). The ranges of hydrogen consumption are from 3 to 250 ml/min with a discreteness of 1 ml/min. The air flow ranges from 10 to 750 ml/min with a discreteness of 1 ml/min. Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. Deviation of the carrier gas flow rate from the average value of ± 1.5% in the flow range from 50 to 100 ml/min and ± 0.5 ml/min in the flow range from 3 to 50 ml/min. The relative deviation of the average steady-state gas flow rate from the set value in the range: from 3 to 100 ml/min. ± 2.5%, but not less than 0.5 ml/min.; from 100 to 200 ml/min. ± 5%; from 200 to 800 ml/min. ± 10%. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption, no more than — 30 VA. Overall dimensions of the FGP (width × depth × height), no more than 160 × 370× 210 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
M532 Raman microscope by Spektr-M
M532 Raman microscope by Spektr-M
1 supp.
The M532® Raman microscope combines the capabilities of the Inspectr R532® Portable Raman Express Analyzer and the U300M microscope, adapting it for both transmission and reflection measurements. The wide functionality of the M532 microscope makes it possible to find and analyze individual particles with a size of 2-3 µm among many similar ones with similar physical and chemical properties, which opens up new research opportunities within the framework of a single Raman system. A spatial resolution of 1 µm and a spectral resolution of 4-6 cm-1 ensure excellent measurement accuracy and reproducibility. The compact design and portability of the instrument allow for high-quality and instant analysis of substances without sample preparation, which makes the M532 microscope an indispensable instrument for a wide range of studies. Equipped with a motorized slide (optional) with a step of 0.36 µm, the M532 microscope scans the surface of the sample, recognizes substances in multi-component heterogeneous mixtures and creates a graphical image of the intensities of Raman scattering characteristic lines at various points on the surface (2D mapping), which makes the M532 microscope the most advantageous in terms of price-quality ratio scanning Raman microscope in the world market.
Spektr-M
Chernogolovka
Produced in: Chernogolovka, Moscow region
Desiccator 2-210 mm Primelab, without tap, light glass
Desiccator 2-210 mm Primelab, without tap, light glass
from 2 621 ₽
Desiccator 2-210 mm PrimeLab is made of light glass and does not have a tap. Designed to store and protect samples in a laboratory environment. Reliable design and precise humidity control create optimal conditions for specific tasks. It has compact dimensions: the diameter is 210 mm and the height is 275 mm, of which 95 are on the lid.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum tube MiniMed with K3-EDTA and separation gel, 5 ml, 13×100mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA and separation gel, 5 ml, 13×100mm, purple, glass, pack.100 pcs
from 1 339 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Glass firing pin for ampoules
Glass firing pin for ampoules
from 250 ₽
Laboratory glassware made of glass.
MiniMed
Suponevo
Produced in: Bryansk region
Flat-bottomed flask P-1-500 29/32 Primelab
Flat-bottomed flask P-1-500 29/32 Primelab
from 471 ₽
The flat-bottomed flask P-1-500 Primelab is equipped with a 29/32 joint, which allows it to be connected to laboratory equipment and carry out various laboratory processes. Suitable for working with chemically active and aggressive substances whose volume does not exceed 500 ml. Made from durable borosilicate glass. A flat-bottomed flask is presented in the shape of a ball with a flat bottom and a high neck, the diameter of which is 110 mm. The total height of the product is 167 mm.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Table island low LAB-PRO SOCN 180.150.75 LA
Table island low LAB-PRO SOCN 180.150.75 LA
Island table Table top: LAMINAT (table top consists of 2 cohesive parts, the seam is treated with moisture-resistant glue) Length, mm: 1800 Depth, mm: 1500 Height, mm: 750 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm) A set of end boxes-plugs
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LABORATORY INSTALLATION FOR MODELING THE PROCESS OF THERMAL CONTACT CRACKING. MKUB.413224.029
LABORATORY INSTALLATION FOR MODELING THE PROCESS OF THERMAL CONTACT CRACKING. MKUB.413224.029
Laboratory installation for modeling the process of thermal contact cracking (TCC) of heavy oil residues (TNO) (heavy oil fuel oil, tar and semi-tar, asphalt of the process of de-asphalting of high-viscosity oils, cracking residue or pitch, heavy gas oil, natural bitumen, etc.) with a movable solid coolant. technical specifications Operating pressure range, MPa 0÷4 Reactor operating temperature range, 0C 50÷800 Reactor inner diameter, mm, 31 Reactor length, mm, 875 Number of thermostatically controlled independent zones 4 Length of each independent isothermal zone of the furnace, mm 200 The length of the full isothermal zone of the furnace, mm 800 Thermocouple Pocket Availability The type of furnace is Casement The power consumed by each independent thermostatically controlled zone of the furnace, W 720 Power consumed by all four zones of the furnace, W 2880 The discreteness of the temperature setting, 0C 1 The flow range of the liquid pump, ml/min 0.1-10 The maximum pressure of the high-pressure liquid pump, not less than 20 MPa Flow range N2, l/min 0÷20 Pressure in the low pressure lines N2 and air, MPa ≤0.6 Operating temperature range of the evaporator-mixer of raw materials, sup>0C 50÷500 Actuation pressure of mechanical safety valves, MPa 3 Maximum pressure in the raw material container, 0.1 MPa Supply voltage 230-240V 60Hz The power consumption of the installation is not more than 3.5 kW The discreteness of the temperatures and flow rates displayed on the displays is 0.1 Installation weight without cabinet, kg 100 Overall dimensions of the installation, mm 1900x865x550 Overall dimensions of the cabinet, mm 2000x880x800 The technical characteristics of the purchased units used in the installation are given in the technical documentation for these units supplied with the installation The length of the supply pipelines, m 10 The coolant of the refrigerator "tosol"
Produced in: Yoshkar-Ola, Mari El