Search

3995 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 522
    Names
    Loading...
  • 127
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 97
    Additional
    Loading...
View:
3995 products
Biosafety cabinet BA-Safe 180
Biosafety cabinet BA-Safe 180
The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1830×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1968,5х766,2х1506,6 Height of base, mm 690
Produced in: Belarus, Minsk
Set of devices for BNTI-05-04 State Standard 20287 method B
Set of devices for BNTI-05-04 State Standard 20287 method B
It is used in determining the pour point of petroleum products in accordance with the State Standard 20287 (method B).
Produced in: Tomsk
"Home officer" Plus Kit
"Home officer" Plus Kit
from 61 620 ₽
Designed for: – measurement and registration of air temperature, temperature of hot water supply, surface of heating devices; – measurement and registration of relative humidity; – saving data to a memory card with subsequent transfer to a PC for generating reports; – measurement accuracy from ± 0.2 ° C.
Produced in: Moscow
Salt low-temperature bath SHS-6.5.6,2/5,5
Salt low-temperature bath SHS-6.5.6,2/5,5
from 2 561 724 ₽
Salt baths (furnaces) are used for low tempering of steels, annealing and heating for hardening of aluminum alloys, for tempering aluminum alloys, for tempering high-speed steel and for the first stage of heating high-speed steel. The low-temperature saltpeter bath SHS-6.5.6.2/5.5 is designed for heat treatment of parts in a saltpeter melt at temperatures up to 550 ° C in stationary conditions.
Produced in: Tula
Furnace control cabinet SHUP-25-1
Furnace control cabinet SHUP-25-1
Designation SHUP-25-1 Switching power, kW 25 Automatic switch, A 50 Supply network voltage, V/Hz 380
Produced in: Tula
Laboratory mill BLIZZARD 3M
Laboratory mill BLIZZARD 3M
1 supp.
The principle of operation of the mills is based on the grinding of the product, rotating at high speed with a knife in combination with a cyclic rotation of the grinding unit. In order to achieve uniform grinding and homogenization of the sample, the grinding unit must be tilted during grinding. The angle of inclination is set automatically according to the selected mode. FEATURES: 1. Programmable grinding modes The laboratory mill has two grinding modes: "Sunflower" - used for grinding oilseeds. "Grain. Feed" is used for grinding grain, leguminous crops, feed and raw materials for their production. Depending on the crushed product, the operator selects the desired mode of the grinding process. The installation of the grinding mode options is carried out using a specially developed program via a PC. It is possible to install an additional grinding mode using a PC. 2.Easy operation with information display. 3. Crushing of samples with a high fat content (up to 55%). 4. Sample preparation without heating. The special design of the grinding chamber (grinding is carried out in the upper bowl made of aluminum) and the use of special knives ensure rapid grinding and minimize heating of the sample, which eliminates moisture loss. According to the test results of FSUE "UNIIM", mills are recommended for sample preparation during the analysis to determine humidity. They are part of the installation of the measuring air-thermal ASESH-8 (RU. p.31.005.A No. 56847). 5. COOLING SYSTEM without forced water cooling. For continuous comfortable operation with the cooling system, the mill is equipped with two grinding cups. 6. Grinding of various types of samples. The presence of knives of various geometries and the possibility of their quick replacement when changing the crushed product, allows the mill to be used for grinding a wide range of agricultural products – from wheat grains to soybeans and sunflower seeds, according to specially developed algorithms. Knives are included in the delivery package of the mill: knife No. 2 – for grinding oilseeds and cereals; knife No. 4 – for grinding feed and raw materials for their production; knife No. 1 – designed for chopping soybeans.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
NV-1200 SP Desk (1200×600×750)
NV-1200 SP Desk (1200×600×750)
from 10 991 ₽
The NV-1200 SP is a relatively small and inexpensive desk with a countertop width of 1200 mm. It is designed for routine office work in the laboratory. The height of the table is 75 cm (like a regular office desk). The whole table is made of laminated chipboard (chipboard 16 mm thick) and edged on the facade with a 2 mm PVC edge, which increases its impact resistance and mechanical strength. In the right-hand side of the cabinet there are three drawers for storing papers, office and other necessary small stuff. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table when assembled (W×D×H): 1200×600×750 mm. Advantages of NV-1200 SP tables An inexpensive solution for laboratories that value the reliability and durability of furniture; Suitable for very small rooms; It is convenient to work while sitting: the height of the work surface is 75 cm (the height of an average office desk). Application of NV-1200 SP tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Correlational leakage detector Iskor-259KD
Correlational leakage detector Iskor-259KD
from 1 206 810 ₽
The set is correlational-acoustic, with graphical indication of the communication axis and digital depth of occurrence. Designed for: • – determination of the location of leakages from pipelines by the correlation method; • – tracing underground utilities with the display of the communication axis and digital measurement of the depth of occurrence; • – built-in GPS/GLONASS module for saving coordinates with subsequent mapping of the communication route on the map; • – clarification of leakage sites by acoustic leak detector; • – creation of an information database on the condition of pipelines and the results of pipeline diagnostics; • – diagnostics of shut-off valves.
Produced in: Kolomna, Moscow region
Pure Nitrogen Generator GCHA-15D-K
Pure Nitrogen Generator GCHA-15D-K
from 352 800 ₽
The characteristics of the device are similar to the GCHA-18D-K model. The difference is the generator capacity of 15 liters /hour. An oil-free compressor is also built into the generator, which ensures complete autonomy of the device. The warranty for the device is 18 months, for the built–in compressor - 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % vol. (including impurities of inert gases: argon, neon, helium) 99,999 Volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) Volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a concentration of methane in the supply air not more than 5 ppm)* 0.00001 (0.1 ppm) Maximum nitrogen capacity is not less than 15 liters/hour (250 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Noise level generated by the compressor is no more than 45 dB Power consumption is not more than 200 VA Overall dimensions, (width x depth x height) are not more than, mm 230x470x510 Weight is not more than, kg 23 Working conditions: Ambient temperature, °C from +10 to +35 Electric power supply from a single-phase AC network with a voltage of 220 ± 10% and a frequency of 50 ± 1 Hz Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Focusing prefix MKF-Yu
Focusing prefix MKF-Yu
It allows recording transmission spectra of objects with sizes from 500 microns (precious stones, optical parts, semiconductor materials). It is also used in the study of samples compressed into small-diameter tablets with KBr (the method is convenient for spectral analysis of powdery substances - the prefix allows you to work with small amounts of the sample using a manual press for the manufacture of tablets). • The diameter of the focus spot is less than 3 mm • The design uses parabolic mirror optics • The set-top box is equipped with a set of replaceable diaphragm holders for samples of different sizes • Windows-substrates made of IR-transparent materials can be placed in the holder after pasty, liquid substances or extracts are applied to them, followed by drying of the layers • The slide table has the possibility of smooth movement in vertical and horizontal directions to achieve the maximum signal level
SIMEKS
Novosibirsk
Produced in: Novosibirsk
EVRAZCOMB – 3 in 1
EVRAZCOMB – 3 in 1
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk