Search

62 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 1
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 18
    Applying
    Loading...
  • Names
    Loading...
  • 14
    Manufacturer
  • 13
    Made in
  • 8
    Additional
View:
62 products
SRK‑AT2327 ALARM METER WITH INFORMATION BOARD
SRK‑AT2327 ALARM METER WITH INFORMATION BOARD
Logging data on dose rate levels and exceeding threshold levels The possibility of placing the detection unit and the temperature sensor at a distance of up to 1 km separately from the scoreboard Additional protection from direct exposure to precipitation
Produced in: Belarus, Minsk
measuring air-thermal installation  ASESH-8-2
measuring air-thermal installation ASESH-8-2
1 supp.
Implements a thermogravimetric (air-thermal) method for determining the mass fraction of moisture, based on measuring the mass of the sample of the analyzed substance before and after drying, followed by calculating the values of the mass fraction of moisture. Air-thermal measuring installations ASESH-8 are registered in the State Register of Measuring Instruments under No. 58526-14, have a certificate of approval of the type of measuring instruments OC.C.31.005 And No. 56847.The installations undergo initial verification and have the appropriate certificate. General characteristics: - The presence of two independent drying chambers. - Possibility of simultaneous determination of humidity of 12 samples: Each drying chamber of the installation consists of 6 independent cells. You can put 2 buckets in each cell. Total capacity of the ASES Installation-8-2 – 24 bucs. - Convenient access to the cells of the drying chamber: On the front side of the cabinet there are four doors for access to the cells. - Natural ventilation: The absence of rotating elements ensures absolute noiselessness of operation and a long service life. - Built-in timer: The ASESH-8-2 installation has 4 timers, by means of which the end of the drying process is monitored in each section with the output of an audible signal and a light indication. - The output to the operating mode is 30 minutes: The power of air-thermal installations is 1200 watts. When entering the operating mode, the power consumption is the same as that of similar cabinets with low power. SCOPE OF DELIVERY : 1. Installation of ASESH-8-2 2. AO-3 cooler 3. Auxiliary accessories 4. Air-heat control unit: 5. Interface unit for connecting a personal computer with a scale (available on request); 6. software for processing and archiving measurements of humidity determination data; The program allows you to: Set the operating temperature in the chambers via a personal computer Set the necessary parameters of the sample drying process according to the selected method Display all current processes (predrying, drying, cooling) and parameters (temperature, time) during the tests. To monitor the process by means of an electronic timer with the output of an audible signal. Record all weighing results. Perform humidity calculations in accordance with standardized methods. To calculate the humidity with pre-drying, the program uses formulas that allow you to get an accurate result. Archive and print test results. According to the test results of FSUE "UNIIM", it is recommended to use a laboratory mill of the BLIZZARD series for sample preparation. SCOPE OF APPLICATION: 1. Crop production, agriculture and forestry. 2. Products of meat, dairy, fish, flour-milling, feed and microbiological industries. 3. Food industry products. 4. Cellulose, paper, cardboard and products made from them. 5. Medicines, chemical and pharmaceutical products and medical products. 6. Building materials. 7. Products of the logging and sawmilling and woodworking industry. 8. Ground, soils, mineral fertilizers. Technical specifications: The measurement range of the mass fraction of moisture, % from 0.5 to 80 Operating temperature range, °C from 45 to 160 The error of setting and maintaining the temperature in the working area, ° C, not more than 2.0 Limits of permissible absolute error, % ± 0.5 Power consumption, V• A, not more than 1200 Overall dimensions, mm 240 × 260 × 640 Overall dimensions of the cell, mm 75 x 40 x 165 (depth) Weight, kg 28.4
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
The field of fast and thermal neutrons in a collimated beam Fast neutron field in “open” geometry using a screening cone according to ISO 8529-2 Drum source magazine with polyethylene and concrete protection at a depth of 1 meter Software control of the movement of sources and positioning of the mobile platform An alarm and blocking systems, radiation monitoring Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring recorder IS-203.2.0
Measuring recorder IS-203.2.0
from 24 480 ₽
The meter-recorder IS-203.2 is a microprocessor-based meter designed to measure temperature. Equipped with a non-volatile storage device and a real-time clock. The device has two measuring channels. The measurement results are stored in the non-volatile memory with a volume of 15,000 measurements per channel. The operating conditions of the meter IS-203.2.0 Ambient temperature, ° C: -20...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7. Scope of application of the meter IS-203.2.0 Control of technological processes in various industries, including: utilities, construction, food and pharmaceutical industries, agriculture, etc. Warehouses (grocery, industrial, pharmaceutical, etc.). Transportation (grocery, industrial, pharmaceutical, etc.). Functionality of the meter IS- 203.2.0 Temperature measurement by external sensors. Saving the measurement results in the device memory. Indication of the results of current measurements, time, channels included, interval between measurements, free memory of the device, battery capacity, serial number of the device, time of the next measurement. Operational start and stop of the measurement process. Data transfer to a PC via a COM port or USB.
Produced in: Kolomna, Moscow region
VE-26NP Eddy current structuroscope
VE-26NP Eddy current structuroscope
from 175 000 ₽
Distinctive features: The built-in thermometer allows you to take into account the influence of ambient temperature and improve the measurement accuracy. The built-in memory stores 4096 electrical conductivity measurement results for subsequent transfer to a PC. Specifications: Measuring range of the absolute value of specific electrical conductivity, MSm/m from 5 to 60
Measuring range of increments of electrical conductivity, MS/m from -9.99 to +9.99 Limit of permissible basic relative measurement error, % no more than 2 Permissible gap between the transducer and the surface of the controlled product, mm, no more than 0.25 Digital display of measurement results Power supply from RRZ type battery, V 9 Power consumption, mW, no more than 40 Operating temperature range, °C 5...40 Dimensions, mm 57*84*30 Weight, g 270±20
Produced in: Moscow
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software Mobility and the possibility to organize the control of passages in a short time High reliability and self-control Backup power supply
Produced in: Belarus, Minsk
MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
Scope of application · measurement of electrical energy parameters in three-phase or single-phase current networks with their subsequent transmission to the upper level of the AIS · the device of the lower level in the AIS at the facilities of generation, conversion, transmission and distribution of electricity
PARMA
Saint Petersburg
Produced in: Saint Petersburg
The self-recording meter IS-203.1.0
The self-recording meter IS-203.1.0
from 8 940 ₽
The measuring recorder IS-203.1.0 is designed to measure and register temperature with a specified time interval between measurements by direct contact of the device with the measuring object. The features of the meter IS-203.1.0 Ease of operation. Reliability. The operating conditions of the meter IS-203.1.0 Ambient temperature, ° C: -30...+85. Relative humidity, %: no more than 80% at T = 35 ° C. Atmospheric pressure, kPa: 86...106.
Produced in: Kolomna, Moscow region
SPECTROMETRIC RADIATION MONITORING SYSTEM
SPECTROMETRIC RADIATION MONITORING SYSTEM
Displaying the spectra and dose rates measured by each detection unit (DB) on the object plan or terrain map Identification of the radionuclide composition of the source The possibility of expanding the energy range up to 5 MeV Sealed DB design (IP68) Backup power supply
Produced in: Belarus, Minsk
The self-recording meter IS-203.1.1
The self-recording meter IS-203.1.1
from 8 520 ₽
The measuring recorder IS-203.1.1 is designed to measure and register temperature with a specified time interval between measurements by direct contact of the device with the measuring object. The features of the meter IS-203.1.1 Ease of operation. Reliability. The operating conditions of the meter IS-203.1.1 Ambient temperature, ° C: -30...+85. Relative humidity, %: no more than 80% at T = 35 ° C. Atmospheric pressure, kPa: 86...106.
Produced in: Kolomna, Moscow region