Pure Hydrogen Generator GVCH-36A
Pure Hydrogen Generator GVCH-36A
from 447 600 ₽
The characteristics of the device are similar to the model GVCH-12A (GVCH-25A). The difference is the generator capacity of 36 liters / hour, the purity of the produced hydrogen is lower (99.998% vol). Technical specifications Purity of hydrogen in terms of dry gas is about 99.998 % Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 36 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.03 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.06 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
NV-600 TD Cabinet on wheels with two doors (600*460*650)
NV-600 TD Cabinet on wheels with two doors (600*460*650)
from 5 737 ₽
The NV-600 TD cabinet on wheels has two doors, a shelf-insert and wheels. The standard version of the cabinet on wheels for the laboratory table includes: 2 hinged doors; insert shelf; 2 mm shockproof PVC edge on the countertop and facade; plastic wheels. In the standard version, we offer cabinets for laboratory tables in gray color. However, in agreement with the customer, it is possible to change the color to white, without increasing the cost. We are also ready to adapt the size and materials so that they meet your needs.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Pure Hydrogen Generator GVCH-12A
Pure Hydrogen Generator GVCH-12A
from 303 600 ₽
The device is equipped with an automatic regeneration system of fine filters, which reduces the maintenance of the device to a minimum. In terms of the totality of technical characteristics and ease of operation, it has no equal among similar laboratory hydrogen generators. The hydrogen capacity is 12 liters/hour (200 ml/min). Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1 atm is not more than 5ppm Total hydrogen capacity, reduced to normal conditions is not less than 12 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 180 VA maximum (at startup) is no more than 220 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage 220 V(+10 -15)% and frequency 50 +1 Hz The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Universal calibrator H4-24
Universal calibrator H4-24
The main field of application of the calibrator is the verification of measuring instruments. The calibrator is capable of operating both independently and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 and ETHERNET. Technical specifications Ranges of reproduction of electrical quantities: - constant electrical voltage from 0 to 1000 V - alternating electric voltage in the frequency range from 10 Hz to 70 kHz from 0.9 mV to 1050 V - alternating electric voltage in the frequency range up to 100 kHz up to 750 V - alternating electrical voltage in the frequency range up to 1 MHz to 110 V - the power of direct electric current from 0 to 2 A - the power of alternating electric current in the frequency range from 10 Hz to 10 kHz from 0.9 µA to 2 A - electrical resistance of 1, 10, 100 ohms, 1,10,100 kOhm, 1,10,100 mOhm Errors in the reproduction of electrical quantities: - constant electrical voltage ± (0.0012 – 0.003)% of U + (0.0003 – 0.015)% of Up - alternating electric voltage in the frequency range from 10 Hz to 1 MHz ± (0.007 – 0.3)% of U + (0.001 – 0.25)% of Up - DC current ± (0.004 – 0.007)% of I + (0.001 – 0.01)% of Ip - AC electric current in the frequency range from 10 Hz to 10 kHz ± (0.015 – 0.1)% of I + (0.002 – 0.1)% of Ip - electrical resistance ± (0.002 – 0.005)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 480x200x550 Weight, not more than 35 kg
Produced in: Moscow
CD-1 Paint detector of defects 220V
CD-1 Paint detector of defects 220V
from 60 000 ₽
The principle of operation: The controlled extended product (pipe, rolled or wire) is passed through the working area of the flaw detector. When a defective area is detected, the flaw detector included in the automated system sends a signal to trigger the paint meter actuator, as a result of which the paint from the marker's aerosol can is applied to the surface of the controlled product through a window in the device housing. Features and benefits: - Any standard aerosol cans with a diameter of 68 mm can be used in the flaw detector; - Easy replacement of the cylinder; - The device does not require connection to the pneumatic line; - High performance; - The design of the CD-1 defect meter allows connection to any standard AC and DC electrical networks with rated voltages from 12 to 380 V. Scope of application: The CD-1 automatic paint sprayer is an auxiliary equipment and is used in conjunction with flaw detectors as part of in–line automated lines for marking defects in quality control of extended products made of various materials, ferrous and non-ferrous metals and alloys - welded, hot-rolled and cold-drawn pipes, rolled products, wire and products made of them. The flaw detector can be used both in the production process and during input control on the consumer side at machine-building, transport, chemical and oil and gas enterprises. *Custom-made versions for rated voltages can be of: 12, 24, 48, 110, 127, 220, 380V.
Produced in: Moscow
In situ bioprinter
In situ bioprinter
The first Russian In situ bioprinter for printing in the wound bed is a robotic complex for studying surface damage to restore tissues and organs directly in the patient's body. The in situ bioprinter is suitable for biomedical research in the field of tissue engineering in the laboratory. The bioprinter works with various types of hydrogels (including collagen of the first type) with the addition of cells, growth factors, etc. The printing time depends on the size of the defect and takes about 5 minutes on average. The device complex consists of a 6-axis robot, a 3D scanner and a biomaterial dispenser. The printing process includes scanning, tracing, and applying the material. Currently, the In situ bioprinter is at the stage of obtaining a medical device registration certificate for subsequent use in clinical practice. Improved wound healing dynamics strongly suggest that in situ bioprinting can be used as a new successful therapeutic method for the treatment of soft tissue defects. Significant advantages: ● Performs bioprinting even on a dynamically changing surface (optional: adaptation to micro-movements or breathing of the patient) ● Versatile in the use of different types of hydrogels (both sodium alginate and collagen; with and without cells, etc.) An important feature of the In situ bioprinter is that the bioprinter is suitable for various industries and can act as a "classic" 3D printer.
MISIS
Москва
Produced in: Moscow
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
High-frequency signal generator G4-232
High-frequency signal generator G4-232
A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
Produced in: Moscow
OCTAVE-111 Noise meter, spectrum analyzer
OCTAVE-111 Noise meter, spectrum analyzer
Functionality ■ Sound level measurement: Class 1 according to GOST 17187-2010, IEC 61672-1 ■ Measures sound pressure levels in octave and third octave frequency bands ■ Has a metal body, resistant to external influences ■ Automatic recording of measurement results in memory ■ Non-volatile memory ■ Telemetry channel, remote control and operation of the device Features ■ Easy setup: one measurement mode, all values are measured simultaneously ■ Easy to manage: all results are grouped in two windows ■ Measurement of sound levels below 20 dBA ■ Affordable solution Application areas ■ Noise control in residential and public buildings ■ Noise control on the territory of enterprises and residential buildings ■ Production control ■ Vehicle inspection Complies with standards: - as a noise meter: GOST 53188.1-2019 (17187-2010, IEC 61672-1), Class 1 - as a spectrum analyzer: GOST R 8.714-2010, IEC 61260 (Class 1) Noise meter mode - Measuring range of sound levels, dBA: from 19 to 150* - Frequency characteristics: A, C, Z, AU, FI, G - Time characteristics: S, F, I, Peak, Leq * When equipped with 50 mV/Pa microphones and 12 mV/Pa Spectrum Analyzer mode with constant relative bandwidth - Frequency range of digital octave filters, Hz: 31.5 - 16000 - Frequency range of digital third-octave filters, Hz: 25 - 20000
Produced in: Moscow
NV-1210 PC Physical wall-mounted laboratory table (1210×610×1650)
NV-1210 PC Physical wall-mounted laboratory table (1210×610×1650)
from 25 005 ₽
NV-1210 PC is a wall table with a superstructure in the NV line. The table top is made of monolithic ceramic with a depth of 70 cm and a width of 121 cm. A lamp and two sockets are built into the superstructure. It is designed for standing work: the height of the table top is 85 cm. External dimensions of the table (W×D×H): 1210×700×1650 mm. The table top made of monolithic ceramics is moisture-resistant, perfectly withstands high temperatures. It is more resistant to chemicals and heat than ceramic tile since there are no seams. The superstructure allows you to compactly place the necessary reagents and laboratory utensils next to the workplace. Its depth is 25 cm, and its height is 80 cm. The working area is illuminated by a fluorescent lamp (included in the package). The switch is located on the left-hand side of the superstructure. There are also two sockets, one of which is grounded. Sockets have the IP20 degree of protection, maximum load: 1.5 kW. On the right-hand side under the table top there is a built-in cabinet with three drawers. You can store laboratory utensils, equipment accessories or other small things there. The side laminated panels of the table (chipboard 16 mm thick) are edged with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Advantages of NV-1210 PC tables The working surface is made of monolithic ceramics. It is convenient to work while standing: the height of the working surface is 85 cm. On the shelves and in the drawers of the table you can store accessories to the devices on the table, laboratory utensils or reagents. Application of NV-1210 PC tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Nitrogen Generator GA-1200
Nitrogen Generator GA-1200
from 516 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.0 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 1.0 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 7 ati is at least 1380 l/h (23 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Minimum inlet air pressure is 7 ati Maximum allowable inlet air pressure is 8.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 150 l/min Power consumption is not more than 200 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 38 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow