Search

472 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 173
    Names
    Loading...
  • 41
    Manufacturer
    Loading...
  • Made in
  • 47
    Additional
    Loading...
View:
472 products
Individual aspirator BREEZE-2
Individual aspirator BREEZE-2
from 25 500 ₽
The individual aspirator BREEZE-2 is designed to select and measure the volume of maximum one-time, average shift and average daily (in the employee's breathing zone) samples of atmospheric air of populated areas, air of the working area, air of residential and public premises, medical institutions for the content of harmful substances.
Produced in: Moscow
Hydrogen Generators GVCH-6
Hydrogen Generators GVCH-6
from 126 000 ₽
The GVCH-6 hydrogen generators are designed to power flame ionization detectors. They are equipped with a four-stage gas purification system. The hydrogen capacity is 6 liters/hour (100 ml/min). They have smooth adjustment and digital indication of the output pressure. Technical specifications The brand of produced hydrogen "A" according to GOST 3022-80 Purity of hydrogen in terms of dry gas is about 99.995% The concentration of water vapor at 20 ° C and 1.0 ati is not more than 20 ppm Total hydrogen capacity reduced to normal conditions is 6 l/h The range of the specified output pressure of hydrogen is from 1.5 to 6.0 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode is no more than 30 min Volume of bidistilled water to be filled is 1 l Consumption of bidistilled water is no more thann 0.01 l/hour Consumption of bidistilled water is 1.6 g/l of hydrogen Average power consumption in stationary mode is no more than 100 VA Maximum power consumption (at startup) is no more than 150 VA Overall dimensions of the generator, (width x depth x height) are not more than 180x450x435 mm The mass of the generator is not more than 11 kg Working conditions: ambient temperature, °C from +10 to +35 Power supply from single-phase mains: AC voltage, 220±10% and frequency, Hz 50 ± 1
Produced in: Moscow
Induction vacuum electric furnace IVP-1-22
Induction vacuum electric furnace IVP-1-22
a massive copper mold was used in the furnace, as well as a printed crucible made of stabilized (calcium oxide) zirconium dioxide. The furnace has been working for several years at one of the non-ferrous metallurgy enterprises in the production of platinum ingots according to GOST
VakETO
Mosrentgen
Produced in: Moscow
NV-1200 Ln Laboratory tables (1090×700×750)
NV-1200 Ln Laboratory tables (1090×700×750)
from 12 557 ₽
NV-1200 Ln are laboratory tables with a metal frame and a tabletop width of 1090 mm. They are designed for sitting work (the height of the table is 750 mm, this is the height of a regular office desk). The NV-1200 tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table assembled (W×D ×H): 1090×700×750 mm. The working surface for your tasks We offer laboratory tables with various working surface materials. Version: Countertop NV-1200 LLn: Laminate. A budget solution, suitable for school chemistry and physics classrooms, office work, placement of devices. NV-1200: LSPn. Chemically resistant plastic. A good choice for training workshops, analytical and medical laboratories. It does not tolerate high temperatures well, heating devices should not be placed on the surface. NV-1200 LKn: Porcelain tile. A practical solution for most chemical, biological, medical laboratories and workshops. You can put drying cabinets, baths and other heating devices on it. NV-1200 LNn: Stainless steel. Stainless steel is well suited for biological or medical laboratories, but it is not recommended for use in chemical laboratories. It has limited resistance to short-term exposure to concentrated mineral acids and alkalis and is destroyed by prolonged exposure to concentrated acids. NV-1200 LDl: Polypropylene. A specialized solution for chemical laboratories working with inorganic solvents. Advantages of NV-1200 Ln tables A budget solution for laboratories that value the reliability and durability of furniture; Suitable for small rooms; Heating plates or baths can be placed on the granite surface resistant to high temperatures; It is convenient to work while sitting: the height of the work surface from the floor is 75 cm, this is the height of an ordinary office desk. Application of tables NV-1200 Ln Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
NV-1500 SM microscopy table (1500×700×750)
NV-1500 SM microscopy table (1500×700×750)
from 8 578 ₽
The NV-1500 SM is a specialized table for microscopy. The table top is 70 cm deep and is made of laminate. It is designed for sitting work: the height from the floor to the countertop is 75 cm (this is the height of a regular office desk). External dimensions of the table (W×D×H): 1500×700×750 mm. A small superstructure allows you to compactly place the necessary drugs and accessories next to the workplace. Its dimensions: (W×D×C): 668×120×200 mm. The table top is made of laminated chipboard. It is relatively moisture-resistant, resistant to short-term exposure to acids, alkalis and organic solvents and is well suited for the placement of devices. The side laminated panels of the table (chipboard 16 mm thick) are edged with a PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
NV-400 SHR Single-section cabinet for chemical reagents (400×460×1820)
NV-400 SHR Single-section cabinet for chemical reagents (400×460×1820)
from 9 421 ₽
The NV-400 SHR cabinet for storage of chemical reagents with 4 shelves-inserts. It has doors in the upper and in the lower parts. The cabinet is made of laminated chipboard with a shockproof PVC edge of 2 mm on the facade. The standard version of the laboratory cabinet for storing chemicals NV-400 SHR includes: 2 doors (top and bottom); 4 liner shelves; 2 locks
NV LAB
Moscow
Produced in: Moscow, Moscow region
Vacuum-gas-filled electric furnace for chemical and thermal treatment of VE products-2—20- PZ
Vacuum-gas-filled electric furnace for chemical and thermal treatment of VE products-2—20- PZ
The service life of the furnace at a temperature of 1800 OC is not less than 500 hours; number of thermal cycles, not less than 100
VakETO
Mosrentgen
Produced in: Moscow
Pure Hydrogen Generator GVCH-36A
Pure Hydrogen Generator GVCH-36A
from 447 600 ₽
The characteristics of the device are similar to the model GVCH-12A (GVCH-25A). The difference is the generator capacity of 36 liters / hour, the purity of the produced hydrogen is lower (99.998% vol). Technical specifications Purity of hydrogen in terms of dry gas is about 99.998 % Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 36 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.03 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.06 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
NV-600 TD Cabinet on wheels with two doors (600*460*650)
NV-600 TD Cabinet on wheels with two doors (600*460*650)
from 5 737 ₽
The NV-600 TD cabinet on wheels has two doors, a shelf-insert and wheels. The standard version of the cabinet on wheels for the laboratory table includes: 2 hinged doors; insert shelf; 2 mm shockproof PVC edge on the countertop and facade; plastic wheels. In the standard version, we offer cabinets for laboratory tables in gray color. However, in agreement with the customer, it is possible to change the color to white, without increasing the cost. We are also ready to adapt the size and materials so that they meet your needs.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Pure Hydrogen Generator GVCH-12A
Pure Hydrogen Generator GVCH-12A
from 303 600 ₽
The device is equipped with an automatic regeneration system of fine filters, which reduces the maintenance of the device to a minimum. In terms of the totality of technical characteristics and ease of operation, it has no equal among similar laboratory hydrogen generators. The hydrogen capacity is 12 liters/hour (200 ml/min). Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1 atm is not more than 5ppm Total hydrogen capacity, reduced to normal conditions is not less than 12 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 180 VA maximum (at startup) is no more than 220 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage 220 V(+10 -15)% and frequency 50 +1 Hz The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Universal calibrator H4-24
Universal calibrator H4-24
The main field of application of the calibrator is the verification of measuring instruments. The calibrator is capable of operating both independently and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 and ETHERNET. Technical specifications Ranges of reproduction of electrical quantities: - constant electrical voltage from 0 to 1000 V - alternating electric voltage in the frequency range from 10 Hz to 70 kHz from 0.9 mV to 1050 V - alternating electric voltage in the frequency range up to 100 kHz up to 750 V - alternating electrical voltage in the frequency range up to 1 MHz to 110 V - the power of direct electric current from 0 to 2 A - the power of alternating electric current in the frequency range from 10 Hz to 10 kHz from 0.9 µA to 2 A - electrical resistance of 1, 10, 100 ohms, 1,10,100 kOhm, 1,10,100 mOhm Errors in the reproduction of electrical quantities: - constant electrical voltage ± (0.0012 – 0.003)% of U + (0.0003 – 0.015)% of Up - alternating electric voltage in the frequency range from 10 Hz to 1 MHz ± (0.007 – 0.3)% of U + (0.001 – 0.25)% of Up - DC current ± (0.004 – 0.007)% of I + (0.001 – 0.01)% of Ip - AC electric current in the frequency range from 10 Hz to 10 kHz ± (0.015 – 0.1)% of I + (0.002 – 0.1)% of Ip - electrical resistance ± (0.002 – 0.005)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 480x200x550 Weight, not more than 35 kg
Produced in: Moscow