NV-1500 LX-O Table for chromatograph (1500×700×850)
NV-1500 LX-O Table for chromatograph (1500×700×850)
from 20 657 ₽
The NV-1500 LX-O are specialized laboratory tables on a reinforced metal frame with a countertop width of 1500 mm. They are designed to accommodate heavy instruments, such as chromatographs or other analytical equipment. In the upper right corner of the table there is an electric panel with two sockets. Both sockets with grounding and shutters are designed for current up to 16 A and voltage up to 250 V. Working surface material: porcelain tile. It is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. It has limited resistance to hydrofluoric acid. This is one of the most popular types of countertops for laboratory furniture. The tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table when assembled: 1500×700×850 mm. It is designed for standing work.
NV LAB
Moscow
Produced in: Moscow, Moscow region
NV-1200 SHV-B Fume cupboard with countertop made of granite tiles
NV-1200 SHV-B Fume cupboard with countertop made of granite tiles
from 58 531 ₽
Kors NV-1200 SHV-B laboratory fume hoods are single—frame cabinets with a width of 1100 mm with a countertop made of granite tiles. External dimensions of the cabinet (W×D×H): 1100×700×1960 mm. Dimensions of the working area (W×D×H): 1068×540×750 mm. Table top: granite tiles. Convenient fume cupboards for comfortable work in the laboratory The cabinet is available in two versions: with a hood from the lower cabinet and without it. In a cabinet with a hood, various aggressive reagents can be stored, in a cabinet without a hood, it is better to store only laboratory glass or instruments. Working surface material: porcelain tile. It is moisture-resistant, perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. It has limited resistance to hydrofluoric acid. This is one of the most popular choices for work surfaces, suitable for most laboratories. Drying cabinets or other highly heated appliances can be placed on such a countertop. The working area is closed by a single lifting frame with a counterweight. It has two exhaust zones: the hood of the exhaust box and the level of the countertop. Diameter of the flange for connection to the ventilation system: 150 mm. Working area size (W×D×H): 1068×540×750 mm. Please note that the cabinet narrows upwards. At a height of 50 cm, the depth of the working area will be 410 mm, at a height of 70 cm: 365 mm. If you need to place high equipment, then make sure that it corresponds to the dimensions of the camera, otherwise you will not be able to close the cabinet. The height of the raised glass above the cabinet: 510 mm, that is, with the glass raised, the total height of the cabinet will be 2470 mm. The working area is illuminated by a fluorescent lamp (included in the package). The switch is located on the right side of the cabinet, next to the sockets. The fume cupboard is equipped with two sockets, one of them with grounding. Sockets with IP20 degree of protection, maximum load: 1.5 kW. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The legs of the cabinet are adjustable in height within two centimeters, allowing you to place the cabinet even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Particle counter AZ-10
Particle counter AZ-10
from 253 400 ₽
The measuring device AZ-10 is designed to control the dustiness of special industrial premises, and can also be used to check filtering devices
Produced in: Moscow
ST-07 Electrostatic Field Parameter Meter
ST-07 Electrostatic Field Parameter Meter
from 97 200 ₽
It is intended for express measurements in residential and working premises of biologically hazardous levels of electrostatic fields, the sources of which are electrical installations, information display media (computer displays, televisions, slot machines), as well as finishing building materials.
Produced in: Moscow
NV-1000 MD wash table with a dryer (1000×600×1650)
NV-1000 MD wash table with a dryer (1000×600×1650)
from 35 249 ₽
The NV-1000 MD is a large table with two deep polypropylene sinks and a built—in dryer for 18 dishes. It is designed for standing work: its height is 85 cm. Dimensions when assembled (W×D×H): 1000×600×1650 mm. The table top is made of laminated chipboard. It has two built-in Stegler WJH0357F polypropylene sinks. Internal dimensions of each sink (W×L×H): 490×390×290 mm. Polypropylene is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents and suits perfectly for washing laboratory dishes. The package includes a stainless steel mixer with flexible 300 mm tap connectors and a siphon. The upper part of the inclined shelves of the dryer, on which dishes are placed, is covered with a polypropylene insert to protect it against water and reagents. The 18 pins are also made of polypropylene. The side laminated panels of the table (chipboard 16 mm thick) are edged on the facade with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Advantages of NV-1000 MD tables A wide table with two polypropylene sinks and a dryer for 18 dishes. An inexpensive solution for laboratories that value the reliability and durability of furniture. The polypropylene is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. Application of NV-1000 MD tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
X-ray Radiation Dosimeter clinical DRK-1M-CT
X-ray Radiation Dosimeter clinical DRK-1M-CT
Purpose: measurement of the product of the air kerma by length, followed by the calculation of the CTDI tomographic dose index (using the CTDI phantom) for the following calculation of the effective dose received by the patient; monitoring the stability of medical X-ray machines during their operation; calculation of the dose index of a computer tomograph (MPCT) according to GOST R IEC 61223-2-6-2001.
Doza
Zelenograd
Produced in: Moscow
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 200 400 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
rhVEGF-A165
rhVEGF-A165
from 6 600 ₽
Vascular Endothelial Growth Factor is one of the key regulators of angiogenesis. The most important role in the human body is played by a protein of the VEGF family called VEGF-A. VEGF-A is a 45 kDa glycoprotein homodimer and plays a key role in chemotaxis and angioblast differentiation, endotheliocyte (EC) proliferation, vasculogenesis, and vascular remodeling. As a result of alternative splicing or proteolytic cleavage, 4 main isoforms of VEGF-A are formed, consisting of 121, 165, 189, or 206 amino acid residues.
Produced in: Moscow
PM-8 verification module
PM-8 verification module
The composition of the PM-8 verification module Frequency comparator CHK7-1011; Universal frequency meter Ch3-89; AC voltage voltmeter VK3-78A; Universal voltmeter V7-81; AC voltage calibrator H5-5; High-frequency signal generator G4-227; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Absorbed power wattmeter M3-108; Installation for measuring attenuation D1-24/1; Device for measuring attenuation stepwise D1-25; Computational modulation meter SK3-49; The meter-calibrator of the harmonic coefficient SK6-20; Spectrum analyzer SK4-"Belan 240"; VSWR panoramic meter R2-135; VSWR panoramic meter R2-137; A set of exemplary measures of the transmission coefficient H3-7; Oscilloscope S1-157/4; DC power supply B5-79/1; AC power source B2-7 (2 pcs.); Electronic switch of microwave signals; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage from 3 MV to 1000 V Alternating electric voltage in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Frequency of continuous electromagnetic oscillations from 0.001 Hz to 17.85 GHz The power of continuous electromagnetic oscillations in the frequency range of 20 MHz ... 17.85 GHz from 0.8 to 10 MW Attenuation of electromagnetic oscillations in the frequency range 0.1 MHz ... 17.85 GHz from 0 to120 dB VSWR in the frequency range 0.2 ... 17.85 GHz from 1.03 to 2 Harmonic coefficient in the frequency range of 10 Hz ... 8 GHz from 0.005 to 100 % The amplitude modulation coefficient in the carrier frequency range of 100 kHz ... 17.85 GHz from 0.1 to 100 % Frequency deviation in the carrier frequency range of 100 kHz ... 17.85 GHz from 5 Hz to 1 MHz Phase modulation index in the carrier frequency range 100 kHz ... 17.85 GHz from 1 to 100 radians Phase shift between two harmonic signals in the frequency range 0.1 MHz ... 17.85 GHz from 0 to 360o Ranges of reproduction of electrical quantities: Alternating electrical voltage in the frequency range of 10 Hz ... 2000 MHz from 3 MV to 3 V Harmonic (sinusoidal) signal at a load of 50 ohms in the frequency range of 0.001 Hz ... 30 MHz from 0.01 to 5 V Continuous electromagnetic oscillations in the frequency range of 9 kHz ... 17.85 GHz from minus 120 to 13 dBm 5 and 10 MHz reference frequency signal Attenuation of electromagnetic oscillations in the frequency range 0 ... 3 GHz from 0 to 86 dB Measurement errors of electrical quantities: Constant electrical voltage ± (0.0025 ... 16.7) % Alternating electric voltage in the frequency range 10 Hz ... 2000 MHz ± (0.2 ... 16) % Frequency of continuous electromagnetic oscillations ± (2·10-7 ... 4·10-3) Power of continuous electromagnetic oscillations in the frequency range 20 MHz ... 17.85 GHz ± (4 ... 6) % Attenuation of electromagnetic oscillations in the frequency range 0.1 MHz ... 17.85 GHz ± (0.01 ... 1.2) dB VSWR in the frequency range 0.2 ... 17.85 GHz ± (3 ... 5) K Harmonic coefficient in the frequency range 10 Hz ... 8 GHz ± (0.005 ... 6) % Amplitude modulation coefficient in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.1 ... 9) % Frequency deviation in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.2 ... 80) Hz Phase modulation index in the carrier frequency range 100 kHz ... 17.85 GHz ± (0.02 ... 5) radians Phase shift between two harmonic signals in the frequency range 0.1 MHz ... 17.85 GHz ± (0.01 ... 0.08) o Errors in the reproduction of electrical quantities: Alternating electrical voltage in the frequency range 10 Hz ... 2000 MHz ± (0.16 ... 10) % Harmonic (sinusoidal) signal at a load of 50 ohms in the frequency range 0.001 Hz ... 30 MHz ± (3 ... 5) %; Continuous electromagnetic oscillations in the frequency range of 9 kHz ... 17.85 GHz ± (0.5 ... 3) dB 5 and 10 MHz reference frequency signal ± (2·10-11 – 2,4·10-10) Attenuation of electromagnetic oscillations in the frequency range 0 ... 3 GHz ± (0.2 ... 1.4) dB General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 550 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 3000 VA
Produced in: Moscow
Pure nitrogen generator GCHA-180
Pure nitrogen generator GCHA-180
from 448 800 ₽
GCHA-180 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is not less than, l/h, 180 (3.0 l/min) Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 4200 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 36 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Radiation monitoring system "Frigate"
Radiation monitoring system "Frigate"
A simple and inexpensive radiation monitoring system for radiation-hazardous facilities, such as radionuclide source storages, isotope warehouses, clinical radionuclide diagnostics and therapy departments, PET centers, metrological laboratories where work with ionizing radiation sources is carried out, etc.
Doza
Zelenograd
Produced in: Moscow