CD-1 Paint detector of defects 220V
CD-1 Paint detector of defects 220V
from 60 000 ₽
The principle of operation: The controlled extended product (pipe, rolled or wire) is passed through the working area of the flaw detector. When a defective area is detected, the flaw detector included in the automated system sends a signal to trigger the paint meter actuator, as a result of which the paint from the marker's aerosol can is applied to the surface of the controlled product through a window in the device housing. Features and benefits: - Any standard aerosol cans with a diameter of 68 mm can be used in the flaw detector; - Easy replacement of the cylinder; - The device does not require connection to the pneumatic line; - High performance; - The design of the CD-1 defect meter allows connection to any standard AC and DC electrical networks with rated voltages from 12 to 380 V. Scope of application: The CD-1 automatic paint sprayer is an auxiliary equipment and is used in conjunction with flaw detectors as part of in–line automated lines for marking defects in quality control of extended products made of various materials, ferrous and non-ferrous metals and alloys - welded, hot-rolled and cold-drawn pipes, rolled products, wire and products made of them. The flaw detector can be used both in the production process and during input control on the consumer side at machine-building, transport, chemical and oil and gas enterprises. *Custom-made versions for rated voltages can be of: 12, 24, 48, 110, 127, 220, 380V.
Produced in: Moscow
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
OCTAVE-111 Noise meter, spectrum analyzer
OCTAVE-111 Noise meter, spectrum analyzer
Functionality ■ Sound level measurement: Class 1 according to GOST 17187-2010, IEC 61672-1 ■ Measures sound pressure levels in octave and third octave frequency bands ■ Has a metal body, resistant to external influences ■ Automatic recording of measurement results in memory ■ Non-volatile memory ■ Telemetry channel, remote control and operation of the device Features ■ Easy setup: one measurement mode, all values are measured simultaneously ■ Easy to manage: all results are grouped in two windows ■ Measurement of sound levels below 20 dBA ■ Affordable solution Application areas ■ Noise control in residential and public buildings ■ Noise control on the territory of enterprises and residential buildings ■ Production control ■ Vehicle inspection Complies with standards: - as a noise meter: GOST 53188.1-2019 (17187-2010, IEC 61672-1), Class 1 - as a spectrum analyzer: GOST R 8.714-2010, IEC 61260 (Class 1) Noise meter mode - Measuring range of sound levels, dBA: from 19 to 150* - Frequency characteristics: A, C, Z, AU, FI, G - Time characteristics: S, F, I, Peak, Leq * When equipped with 50 mV/Pa microphones and 12 mV/Pa Spectrum Analyzer mode with constant relative bandwidth - Frequency range of digital octave filters, Hz: 31.5 - 16000 - Frequency range of digital third-octave filters, Hz: 25 - 20000
Produced in: Moscow
VE-26NP Eddy current structuroscope
VE-26NP Eddy current structuroscope
from 195 000 ₽
Distinctive features: The built-in thermometer allows you to take into account the influence of ambient temperature and improve the measurement accuracy. The built-in memory stores 4096 electrical conductivity measurement results for subsequent transfer to a PC. Specifications: Measuring range of the absolute value of specific electrical conductivity, MSm/m from 5 to 60
Measuring range of increments of electrical conductivity, MS/m from -9.99 to +9.99 Limit of permissible basic relative measurement error, % no more than 2 Permissible gap between the transducer and the surface of the controlled product, mm, no more than 0.25 Digital display of measurement results Power supply from RRZ type battery, V 9 Power consumption, mW, no more than 40 Operating temperature range, °C 5...40 Dimensions, mm 57*84*30 Weight, g 270±20
Produced in: Moscow
Acoustic ultrasonic flow meter Volga ML
Acoustic ultrasonic flow meter Volga ML
from 400 000 ₽
The flow meter is fully developed by Russian specialists in the field of acoustics, hydraulics and electronics, and is designed to measure the volumetric flow rate and volume of water in pipelines, mainly medium and large, under pressure, non-pressure and combined (pressure-free) flow modes. The flowmeter is based on ultrasonic "time-pulse" multipath technology for measuring the flow velocity in the measuring range. In addition, depth sensors (primary transducers) - hydrostatic, radar contactless, ultrasonic underwater or ultrasonic contactless - are used to measure the flow in water ducts with a combined or non-pressure flow mode. In the presence of deposits affecting the shape and area of the live section of the flow, sediment level sensors are used. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Inset and overhead primary converters from the inside allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 15000 mm The Volga ML acoustic ultrasonic flowmeter is registered as a type of measuring instrument in the Federal Information Fund for Ensuring the Uniformity of Measurements for No. 78414-20 (MP 2550-0361-2019). The Volga ML acoustic ultrasonic flow meter has been recognized as the winner in the nomination Best Technology of the International Environmental Award EWA Award 2020.
Produced in: Moscow
AD-42IP Acoustic Flaw Detector
AD-42IP Acoustic Flaw Detector
from 442 500 ₽
It is especially effective for use in products made of composite materials (including with honeycomb filler). Distinctive features: The AD-42 IP is a compact acoustic system sensitive to changes in mechanical impedance caused by product defects. The indication of the device indicates that there are voids, non-adhesives, delaminations or changes in the structure of composite materials (including with honeycomb filler and laminated plastics) under the sensor. The device is used to monitor various materials and their combinations. The energy consumption of the unit is low because the converter is switched on when the sensor is placed on the monitored product. Being light enough, the device allows you to perform monitoring in hard-to-reach places or in confined spaces. The results of the control can be stored in the built-in non-volatile memory and transferred to a PC. Converters Options: - 3 types of converters for various tasks Emitters: - 1 or 2 on each converter Switching-on: - The converters are switched on when they are placed on a controlled object. Technical characteristics: Weight, kg: 0.73 Dimensions, mm: 210x150x70 Power supply: 4 AA batteries Work without recharging the battery, h: 8 Battery discharge visual indication The defect alarm is visual on the converter and audible on the instrument panel (or) in headphones.
Produced in: Moscow
Whiteness meter BARS
Whiteness meter BARS
1 supp.
The principle of operation is based on measuring the zonal reflection coefficient of a compacted-smoothed flour surface using a built-in standard. The laboratory white meter BARS is approved as a type of measuring instruments and is registered in the State Register of Measuring Instruments under No. 78409-20. All manufactured devices undergo primary verification and have the appropriate certificate. Due to the two-channel design of the device (the presence of two photometric units and a cuvette with two cells), parallel measurements of the whiteness of one flour sample are carried out simultaneously, the average value is calculated automatically, which significantly reduces the time of analysis. The sealing of the flour sample with a fixed force and pressing against the optical windows ensures the same measurement conditions and eliminates the influence of a subjective factor on the result. The automatic adjustment system based on the built-in standard allows to ensure long-term stability of the device without the need for manual adjustment. During operation, the standard is set to the working position by an additional drive. Mechanical damage or loss of the standard is excluded. The output to the operating mode is no more than 30 seconds. The determination of whiteness is carried out in 15 seconds. To determine the whiteness of flour, the operator needs to fill 2 compartments of the cuvette with the test sample of flour, install the cuvette in the device and start the measurement process. All the results of the whiteness definitions are stored in the archive. The operator has the opportunity to view the electronic measurement log.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Climatostat V3 (TU 26.51.-70-002-63790925-2021)
Climatostat V3 (TU 26.51.-70-002-63790925-2021)
from 460 000 ₽
1 supp.
Climatostat V3 (TU 26.51.-70-002-63790925-2021)- it has a new unique control unit UB-04T with a touch screen. This climatostat is universal, it combines the advantages of climatostats B2 and P2, and, accordingly, can perform the functions of one and the other. It is intended for performing works on biotesting the toxicity of aquatic environments on daphnia and ceriodaphnia crustaceans, as well as microalgae (scenedesmus, etc.) in controlled environmental conditions. In the climatostat, it is possible to install exposure devices of the type (UER or similar) and to carry out the exposure of samples under conditions of rotation of samples with test organisms in a plane located at an angle to the horizontal. This ensures the intensification of gas exchange of liquid samples with the external environment. A slow rotation ensures complete uniformity of conditions (temperature, lighting, gas exchange) in all samples, including control, and as a result - high reproducibility of the biotest conditions and reproducibility of the test results. The climatostat has an on-board network for connecting additional sample exposure devices, 5 (five) preset modes and 8 (eight) user modes for free programming of the climatostating parameters by the operator. It is intended for carrying out biotesting (according to the methods of Zhmur N.S., "Aquaross" 2001, 2007), Grigorieva Y.S. (SFU)., Terekhova V.A. (MSU, LATAP), hazard assessment of nanomaterials according to the methods of Morgalev Yu.N. (TomSU) and others. Used with test objects: Crustaceans Daphnia Magna (Daphnia magna Straus); Crustaceans Ceriodaphnia affinis (Ceriodaphnia affinis); Crustaceans of salty reservoirs Artemia Salina (Artemia salina L); Algae Scenedesmus (Scenedesmus quadricauda). Algae chlorella (Chlorella vulgaris Beijer), etc. Additional features of the controller (UB-04T): - setting the contrast of information display - sound notification of an open door - audio notification of the end of the biotest - graphical intuitive parameter setting scales - Fully Russian-language menu and Russian-language design of all text information of the interface - 3 (three) preset modes with the exact name and a brief description of the techniques (can be increased or decreased at the request of the Customer) - quick correction of backlight brightness in preset modes (two touches) - fast temperature correction of temperature control in preset modes (two touches) - 8 user modes (the number of modes can be increased or decreased at the request of the customer when ordering) - graphical intuitive scales for adjusting the brightness of lumostating, temperature of thermostating, automatic adjustment of the photoperiod (with one touch) - built-in countdown timers for setting the exposure time in the biotest (up to 180 days with a minimum discreteness of 1 min) - notification of the power failure of the device during the test - error notification - the ability to update the controller firmware directly by the user at the place of operation - quick reset to factory presets
Evropolitest
Ivanteevka
Produced in: Moscow region
EPR spectrometer CMS8400 NEO
EPR spectrometer CMS8400 NEO
The CMS8400 NEO is a compact electron paramagnetic resonance spectrometer designed for routine research in physics, chemistry, biology and related scientific fields for direct detection of free radicals and paramagnetic materials. The CMS8400 NEO can be used in both laboratory and industrial settings in the mode of on-line measurements, embedded in technological processes, thus providing control of parameters and reactions in the production process. Additional accessories and adapted software can make the spectrometer an analytical tool and allow to implement new complex applications in medicine, petrochemistry, brewing, sanitary and hygienic control, as well as in other industries.
Produced in: Belarus
Measuring air-thermal installation ASESH-8-1
Measuring air-thermal installation ASESH-8-1
1 supp.
A thermogravimetric (air-thermal) method for determining the mass fraction of moisture is implemented, based on measuring the mass of the sample of the analyzed substance before and after drying, followed by calculating the values of the mass fraction of moisture. Air-thermal measuring installations ASESH-8 are registered in the State Register of Measuring Instruments under No.58526-14, have a certificate of approval of the type of measuring instruments RU.C.31.005 And No. 56847. The installations undergo initial verification and have the appropriate certificate. GENERAL CHARACTERISTICS 1. Convenient access to the cells of the drying chamber On the front side of the cabinet there are four doors for access to the cells. 2. The possibility of simultaneous determination of the humidity of 8 samples The drying chamber of the air-heat installation consists of 8 independent cells with a total capacity of 16 bucs. 3. Built-in timer The ASESH-8-1 installation has 4 timers, by means of which the end of the drying process is monitored in each section with the output of an audible signal and a light indication. 4. Natural ventilation The absence of rotating elements ensures absolute noiselessness of operation and a long service life. SCOPE OF APPLICATION: 1. Crop production, agriculture and forestry. 2. Products of meat, dairy, fish, flour-milling, feed and microbiological industries. 3. Food industry products. 4. Cellulose, paper, cardboard and products made from them. 5. Medicines, chemical and pharmaceutical products and medical products. 6. Building materials. 7. Products of the logging and sawmilling and woodworking industry. 8. Soils, пground, mineral fertilizers.
GK EKAN