TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolytic gas chromatography method is widely used in the study of polymer materials, plastics, rubbers, rubbers, paints and other high-molecular compounds of natural and artificial origin. The method is based on thermal decomposition of sample samples in an inert medium (without oxygen access), followed by chromatographic separation and analysis of the formed volatile compounds. Thus, the resulting pyrogram allows us to judge the composition of the original sample. Pyrolysis is also used in geochemical studies. Technical specifications The volume of the capsule is 56 ml. Pyrolysis temperature — from 200 to 1000 °C. The error of maintaining the temperature is not more than 1.0 ° C. The heating time of the sample to the pyrolysis temperature is no more than 2 seconds. The cooling time of the capsule when moving from the hot zone to the cold zone after pyrolysis is no more than 10 seconds. The time of continuous operation in the pyrolysis mode is no more than 60 seconds. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Power consumption — no more than 100 VA. Overall dimensions of the control unit (width ×depth×height) — 210×190×100 mm. Overall dimensions of the input node (width× depth×height) — 90×135×160 mm. The weight of the control unit is not more than 2.5 kg. The weight of the input node is not more than 0.9 kg.
Produced in: Yoshkar-Ola, Mari El
GAS PANEL
GAS PANEL
The gas distribution panel (hereinafter referred to as the panel) is designed to connect gas nodes and blocks of various analytical instruments, including chromatographs to shop gas lines. technical specifications Inlet pressure, not more than 0.8 MPa. The output pressure is from 0 to 0.4 MPa. Gas flow rate through each channel, not less than — 1000 cm3/min.
Produced in: Yoshkar-Ola, Mari El
HIGH PRESSURE GAS FILTER UNIT
HIGH PRESSURE GAS FILTER UNIT
A block of gas filters for lines with a pressure of up to 15 MPa. The volume, length, connection dimensions, type of connections with supply pipelines are specified when ordering.
Produced in: Yoshkar-Ola, Mari El
AUTOSAMPLER "NT3100A": FUNCTIONS
AUTOSAMPLER "NT3100A": FUNCTIONS
The autosampler is used to automate the process of entering samples of liquid consistency into chromatographs of the line "Kristallux", "Crystal", series "Color", LHM. The autosampler is compact in size and easy to operate. The device is compatible with different models of chromatographs and is suitable for many studies. When the device is working with the Crystallux series chromatographs, the autosampler can be controlled using the chromatographic equipment software, while no additional programs are required.
Produced in: Yoshkar-Ola, Mari El
SYRINGE FILLING DEVICE
SYRINGE FILLING DEVICE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), it is necessary to first fill a syringe with transformer oil with a carrier gas, and then, after achieving an equilibrium distribution of gases dissolved in oil between the liquid and gas phases, introduce the gas phase into the chromatograph (blow out the doses of the chromatograph dispenser tap). Moreover, the operations of filling the syringe and entering the sample are performed without air access. When filling the syringe, it is possible to fix the syringe stem at a certain volume. technical specifications The volume of syringes is 20 or 50 ml. The pressure at the outlet of the syringe filling line with argon is 0.5 atm. The range of ratios of volumes of the gas phase and oil (Vg/Vm) is from 0 to 1.5.
Produced in: Yoshkar-Ola, Mari El
GAS SAMPLER
GAS SAMPLER
They are used for sampling natural and liquefied gas. In the company "Meta-chrome" you can buy the following gas samplers: PGO-50M; PGO-400; BDP 12-2-9,8 (aluminum, subcompact); PU. The PGO-50 M, PGO-400 and PU models are used to take samples of liquefied hydrocarbon gases that are affected by the overpressure of stationary tanks and or their own vapors. Sampling is carried out according to GOST 14921-78. The BTP 12-2-9.8 device is used for sampling, storing and transporting samples of gases that are under pressure. The device is made of aluminum and is designed for a small liter. Sampling is carried out according to GOST 31370-2008. INDICATOR BDP7 BDP7 BDP12 BDP12 BDP16 PGO-400 PGO-50M Volume, l. 0,7 1 2 4 10 0,4 0,05 Outer diameter, mm 70 70 120 120 160 50 35 Length, mm 360 480 368 593 800 400 325 Working pressure, MPa 9.8 5.0 9.0 The number of refills up to the operating pressure, times at least 5000 Case material AMg6M 12X18
Produced in: Yoshkar-Ola, Mari El
Press PKM-12
Press PKM-12
1 supp.
It is used in the manual method of determining the content of raw gluten in wheat and wheat flour and is recommended for the specified products supplied for export. The use of the PCM - 12 press allows to exclude subjective factors affecting the result of the analysis, and to obtain more reproducible results with less manual labor. The press consists of two glass plates with a rough surface, provides a stable fixed gap between the plates. It has a stand and a handle for opening. technical specifications: Overall dimensions, mm 250x185 Thickness of glass plates, mm 10 The gap between the glass plates, mm 2,4 Weight, kg 2.7
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Compact magnetic stirrer PL-R-atom USB, 2 liters. Primelab
Compact magnetic stirrer PL-R-atom USB, 2 liters. Primelab
The speed is set in the range from 150 to 2000 rpm, the timer is up to 99 minutes. Country of origin, Russia Orange color Protection class (according to DIN EN60529), IP21 Number of places for mixing, 1 Maximum volume of mixed liquid, 2 l Range of operating speeds of the motor shaft, 150-2000 rpm Connection – external temperature sensor PT1000 (sold separately) Power: USB port. Dimensions, weight Overall dimensions LxWxH, 160x148x48 mm Diameter of the working surface of the plate, 128 mm Device weight, 0.3 kg Contents of delivery Magnetic stirrer without heating PL-R-atom Operating manual combined with passport Anchor for stirrer in fluoroplastic sheath 5x30 mm; DC power supply, output voltage 9V, rated input voltage ~220V, 50Hz. USB cable
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC and MS interface Capillary direct interface, independent temperature control (50-300 0 S) The filament of the cathode (filament) is a double filament for electron ionization (EI), the maximum current is 300 µA. Double thread increases the service life. Two independent switchable cathodes Temperature of the ion radiation source Independent heating and temperature control, maximum value 350 0 C (adjustable) Transparent polymer window on the front panel there is no visual control of the state of the cathodes Ion radiation source Lenses made of ceramic and with a patented coating enhance the focusing effect, which significantly increases the efficiency of ionization, an electrode with a patented reflective surface improves focusing Tubular lenses enhance the focusing effect, which significantly increases the ionization efficiency, an electrode with a patented reflective surface improves focusing Energy ionization 10-100 eV The mass analyzer is a high-precision quadrupole with a filter that reduces the contamination of the main quadrupole and eliminates the influence of photonic noise on the analysis High-precision molybdenum quadrupole with prequadrupole (replaceable), which reduces the contamination of the main The detector is an electronic multiplier with a high-voltage secondary emiting electrode (dinode) of high energy 3D geometry to improve sensitivity. The amplifier of weak voltage signals effectively reduces network noise, improves the signal-to-noise ratio during electron ionization and provides a large linear dynamic range. It is possible to install an additional detector Mass range 2.0-1200 a.e.m. 1.5-1050 a.e.m. Mass stability Less than 0.1 a.e.m. for 48 hours Signal ratio noise At least 1500:1 with mass to charge (m/z) 272 At least 150:1 with mass to charge (m/z) 272 (with signal filtering 500:1) Linearity Not less than 107 Not less than 106 Precision < 5% RSD 9n=7, SIM, 100 fg OFN) no System sensitivity IDL < 10 fg (SIM mode, OFN according to m/z 272) no Maximum scanning speed 20000 a.m./s 11000 a.m./s Operating modes Scap, SIM, Scan/SIM, MicroScan and the innovative Flexible-SIM algorithm for finding trace amounts of components no Setting Automatic setting MSD on the PFTBA spectrum and m/z control of oxygen, nitrogen and water no Pumping pump Oil plate-rotor vacuum pump with a pumping speed of 66 l/min Oil plate-rotor vacuum pump with a pumping speed of 165 l/min Turbo pump Turbo molecular pump with magnetic levitation, with a pumping speed of 85 l/s (can be replaced by 300 l/s) Turbo molecular pump with magnetic levitation, with a pumping speed of 71 l/s (possible replacement by 260 l/s) RF detector power Allows you to use three points for calibration in the entire mass range and get good linearity in scanning mode Software Rus./ Eng. The ability to search and extract structural, graphical formulas. Library of 240,000 spectra. The ability to isolate individual components from overlapping peaks. In addition to spectra and compounds, the library contains the element name, formula, molecule structure, molecular weight, CAS number, analysis conditions, synonyms, and estimated or measured retention readings. The NIST EI library contains: drugs, metabolites and poisons, pesticides and fungicides, organic substances present in soil, water and air, amino acids, di- and tripeptides, common sample pollutants, common analytical derivatives, etc. Ethernet interface, remote access function implemented Touch screen Display of parameters and monitoring of system status no Built -in power supply Allows you to turn off the detector in normal mode if there is no power supply violation
Produced in: Yoshkar-Ola, Mari El
Electronic Gripper (E3D)
Electronic Gripper (E3D)
Selective detector for organochlorine compounds and other halogens. It is also sensitive to compounds containing oxygen, phosphorus or aromatic rings, but to a lesser extent. Paraffins and simple hydrocarbons almost do not capture electrons and are not registered. The selectivity to hydrocarbons is 108. It is available in two versions — conventional EDD and micro-EDD, mainly for capillary columns (the second version is characterized by increased sensitivity). The level of fluctuation noise is up to 300 MV, the maximum signal is up to 5 V, the design of the ECD allows the use of argon, helium, and hydrogen as a carrier gas, in addition to nitrogen. Technical characteristic: 4.0*10-15 g/s for lindane
Produced in: Yoshkar-Ola, Mari El