Search

396 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 142
    Names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 25
    Made in
    Loading...
  • 37
    Additional
    Loading...
View:
396 products
Support and rotary device OPU-2
Support and rotary device OPU-2
Technical specifications: Azimuth rotation angle from 0° to 360° with a reading of 0.1° The angle of rotation according to the angle of the place from minus 30° to plus 90° with a count of 0.1° The angle of rotation of the polarization plane from minus 95° to plus 95° with a count of 1° The installation height of the axis of the orientation mechanism is from 1.35 to 2.5 m. Note – The maximum height is determined when the rack is installed, the smooth lifting mechanism is fully extended and the legs are fully extended to the stop, extended at an angle of 30° to the axis of the azimuth mechanism. Smooth height adjustment of the axis of the orientation mechanism 0.25 m In terms of strength under climatic and mechanical influences, the rotary support device (OPU) complies with the norms of group 6 GOST 22261-94 Overall dimensions of the OPU - 1687x2500 (shown in the unfolded state at maximum height. The size Ø1687 is the diameter of the circumscribed circle along the vertices of the triangle occupied by the OPU on a horizontal platform) Operating conditions of the OPU: ambient temperature from minus 50 to plus 60 ° C The mass of the OPU is 19.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
NEXT II
NEXT II
14 high-precision stepper motors control all moving parts of the microscope, and intelligent software blurs the line between optical and SPM imaging. NEXT provides continuous magnification from millimeter-scale panoramic optical images to atomic resolution, and intermediate operations such as laser pointing to the cantilever, sample positioning, soft approach and configuration of advanced SPM techniques occur automatically.
Produced in: Moscow, Zelenograd
Mobile laboratory of measuring equipment PLIT-A2-4/1M
Mobile laboratory of measuring equipment PLIT-A2-4/1M
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
Produced in: Moscow
NTEGRA II
NTEGRA II
NT-MDT S.I. presents NTEGRA II, the second generation of the world's most popular AFM. Thanks to additional features and advanced functions, it provides an unprecedented level of modularity and flexibility, becoming a true partner of the researcher. Intelligent, fast, reliable, accurate and undoubtedly easy to use. To eliminate the influence of a noisy environment, the NTEGRA II is supplied in a standard cabinet that provides temperature control, acoustic and vibration isolation. This combination reveals the true nature of NTEGRA II as the most stable AFM in the world, providing a temperature drift of less than 0.2 nm/min.
Produced in: Moscow, Zelenograd
Power supply C14-100
Power supply C14-100
Operating Mode: Continuous Output stabilized current, A: 1-100 Output voltage, V: 0-14 Power supply: Single-phase mains 220 V; 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 3.8 Overall dimensions (W x H x D), mm: 225 x 85 x 220
INZHEKT
Saratov
Produced in: Saratov
NANOEDUCATOR II
NANOEDUCATOR II
NanoEducator II, despite its compactness and ease of operation, supports all basic techniques of atomic force and scanning tunneling microscopy, so it can be used for any routine AFM and STM measurements and experiments in scientific research. Here are the results of some experiments in various scientific applications: Study of atomic structures Study of metallic nanostructures Study of magnetic structures Study of polymer objects Study of biological objects Study of carbon nanomaterials
Produced in: Moscow, Zelenograd
PKV-IB-5,2×2,6
PKV-IB-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
Radiation Monitoring Station Zastava-1
Radiation Monitoring Station Zastava-1
Devices of a new generation, automated stations of continuous radiation monitoring Zastava-1 are designed to organize continuous effective monitoring of the radiation situation and notification of radiation hazards. The stations have up to three independent measurement channels, which allows monitoring simultaneously in several zones. The stations support remote monitoring - they have a connection to a local computer network, Internet access.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Verification module PM-10
Verification module PM-10
The composition of the PM-10 verification module: Wattmeter of passing power M2-35; Complex transmission and reflection coefficients meter "OBZOR-804/1"; Universal voltmeter V7-81 (2 pcs.); High-frequency signal generator G4-229; High-frequency signal generator G4-230; DC power supply B5-79/1 (2 pcs.); AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-3, CT 0.005; The measure of DC electrical resistance is multi-valued MS3055, CT 0.02; Single-digit electrical resistance measures MS3080 (0.1; 1 ohm, CT 0.005); Thermoelectric voltage converter 0.5 V; Kit for measuring coaxial connectors KISK-7M; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical and radio engineering quantities: Operating frequency range from 0.03 to 17.85 GHz Passing microwave power from 0.01 to 10 MW VSWR of the microwave tract from 1.05 to 3 Constant electrical voltage from 10 MV to 1000 V Alternating electric voltage from 1 mV to 750 V Thermoelectric voltage comparison from 0.1 to 0.5 V Ranges of reproduction of electrical quantities: Constant electrical voltage from 1 to 120 V Resistance to direct electric current from 0.01 to 122222.21 ohms Measurement errors of electrical and radio engineering quantities: Passing microwave power ± (1.5 - 2.3) % VSWR of the microwave path ± (4,15 – 10) % Constant electrical voltage ± (0.003 – 20) % Alternating electric voltage ± (0.09 - 15) % Thermoelectric voltage comparison ± (0.01 – 0.1) % Errors in the reproduction of electrical quantities: Constant electrical voltage ± (100 – 200) mV Resistance to direct electric current CT 0.005; 0.02 General technical characteristics: The area occupied by the module is 4 – 8 m2 Weight, not more than 340 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, not more than 2000 VA
Produced in: Moscow
Rubidium frequency standard H1-1013
Rubidium frequency standard H1-1013
Its small dimensions, weight, power consumption, and operating time allow it to be widely used as an embedded source of high-stability signals in frequency measuring devices and complexes, telecommunications systems, navigation and communication systems.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod