VT3 Liquid thermostat
VT3 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 3 liters and a depth of 150 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 3 l Overall dimensions 170x350x430 mm The open part of the bath is 75x35 mm Bath depth 150 mm Weight 11 kg Power consumption 2.2 kW
Produced in: Tomsk
Illumination lamp VIS-T-11-L
Illumination lamp VIS-T-11-L
It provides clear visibility of the labels of viscometers located in the thermostat bath. This creates additional convenience and increases the accuracy of measurements. It is located behind the working bath of the thermostat.
Produced in: Tomsk
Electronic diaphanoscope YANTAR
Electronic diaphanoscope YANTAR
1 supp.
The principle of operation of the electronic diaphanoscope YANTAR is to assess the vitreousness of the image obtained using a digital camera. The vitreous value is calculated using a software-implemented algorithm using special calibration equations. The analysis time is 1 minute. Automation of the vitreous assessment avoids the error associated with the subjective opinion of a specialist. The use of specially developed calibration standards based on optical filters for uniform adjustment of diaphanoscopes permits to coordinate the operation of two or more devices remotely. The interlaboratory error in determining the vitreousness on the devices included in the network does not exceed the standard. All the results of the determination of the vitreousness of wheat with the corresponding grain images are stored in the archive. If necessary, specialists can print the protocols of the current or any of the previous definitions. THE ALGORITHM OF OPERATION: 1. Pour the grains into the cassette and close the lid made of transparent glass. 2. Install the cassette in the diaphanoscope. 3. Launch the program. 4. Choose a product 5. Software processing of the digital image of grains in accordance with the selected product 6. Calculation of computer results. In 2023, a new national standard GOST R "Wheat. Determination of vitreousness by optical-computer method".
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Circulation chiller A160
Circulation chiller A160
A small buffer bath with a volume of 4 liters. Feeding pump with magnetic coupling for external closed-type thermostating systems. Cooling capacity 160 W at +20 °C. Overall dimensions 275x440x350 mm Weight 22 kg Power consumption 1.2 kW
Produced in: Tomsk
MU-500 Oil reflector enlarged
MU-500 Oil reflector enlarged
The MU-500 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens for capturing oil return flow vapors.
Produced in: Kazan
Liquid thermostat VIS-T-11
Liquid thermostat VIS-T-11
Operating temperature range +15...+100 °C Two places for reference or working viscometers. It is suitable for working with reference viscometers, the capillary length of which is 300 mm. Overflow design ensures stability and uniformity of temperature not worse than ± 0.01 °C Bath volume 27 l Overall dimensions 330x280x870 mm The open part of the bath is 80x150 mm Bath depth 530 mm The size of the viewing window is 190x530 mm Weight 24 kg Power consumption 2.2 kW
Produced in: Tomsk
Water distiller AWD-7000F
Water distiller AWD-7000F
Distillers of the company "BELAKVILON" are designed to produce distilled water from tap water. Capacity 6.5 — 7 l/h Dimensions (mm), W x D x H 510 x 465 x 490 Heater 2 x 3.0 kW Cooling water consumption, l/h about 30 — 50 l/h Power supply 230 V ±10%, 50 Hz Switch Differential automatic Water level sensors Reed floats
Produced in: Belarus, Minsk
Electric furnace tubular laboratory SUOL 0,4.4/11
Electric furnace tubular laboratory SUOL 0,4.4/11
from 169 773 ₽
Electric tubular laboratory furnaces are designed for calibration of thermocouples and dilatometers, heat treatment and determination of the melting point of metals, alloys and other work at temperatures up to 1100 ° C in stationary laboratories. SUOL tubular furnaces are used in many industries and agriculture, are indispensable in factory and research laboratories.
Produced in: Tula
Purka liter MEASURE
Purka liter MEASURE
1 supp.
The principle of operation is based on measurement by filling the container for the measured product with 1 liter of grain and measuring the mass of this grain. PECULIARITIES: 1. Drop weight design no assembly required Thanks to a fundamentally new design of the purka, the determination of nature is carried out quickly. Significantly reduced analysis time. No special training of personnel is required to work on the MERA purka. 2. Stability and reproducibility of results. The stable and repeatable movement of the knives ensures the stability of the work of the purka and an accurate, stable, reproducible determination of the nature (± 1g at 10 measurements). 3. Quick and easy cleaning The convenient design of the device permits to clean it quickly and easily. Excess grain is removed into an empty container for the measured product by pressing the "RESET" button. After discarding the remaining grain, the purka is ready for the next measurement. The fundamentally new design of the MERA purka body and the automation of the analysis process allow you to quickly and easily get the result. WORK ALGORITHM: 1.Fill the hopper with grain. 2.Install the empty container for the measured product into the device. 3. Press the "START" button on the control panel. 4. Weigh a container filled with 1 liter of grain and calculate the result. 5. Reset the remaining grain by pressing the "RESET" button. METROLOGICAL CHARACTERISTICS: Indication error, g, no more than ±4.0 Variation of six dimensions, g, no more than 2.1 SPECIFICATIONS: Overall dimensions (L×W×H), mm, no more than 600×230×620 Weight, kg, no more than 48 Power consumption, V×A, no more than 100 Supply voltage with a frequency of 50±1 Hz, V 220 (+15...-20)%
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Holder THERMOTEST-D2-3/9
Holder THERMOTEST-D2-3/9
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm. It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
Produced in: Tomsk
Circulation thermostat LT-412b
Circulation thermostat LT-412b
The LOIP LT-412b modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 12 The working fluid is water, silicone oil. The open part of the bath / depth, mm 190x296/150 Overall dimensions, mm 355x335x350 Weight, kg 11.8
LOIP
Saint Petersburg