FNCH-53
FNCH-53
These LFS can be used in conjunction with waveguide bandpass filters to increase the suppression of spurious signals and expand the upper band of the barrier. Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Bandwidth Fh-Fb at the level of -1 dB, GHz 45-53.6 The barrage band at the level of -30 dB, GHz 60-78 Bandwidth loss, 0.5-1.0 dB
Produced in: Moscow
Digital oscilloscope C8-39
Digital oscilloscope C8-39
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Technical specifications: Vertical deviation :2 Number of channels 0-50 MHz Rise time of PH ≤ 7.0 ns Input impedance 1 ± 0.03 mOhm, 25 pF Deviation coefficients of 5 mV/div - 2 V/div (step 1-2-5) The maximum input voltage is 100 V With a divider of 1:10 250 V The error of amplitude measurements is a≤ 2 % 5 mV...2 V; 10 ns...2 s/del. ADC: 2 channels, 50 MHz, 8 bits Equivalent sampling rate of 2.5 GHz Marker measurements U: ±2.5%, T: ±1.5% Pre-launch 8 screens, post-launch 150 screens Simultaneous observation of 2 signals Cursor measurements DU and DT Averaging modes and automatic DU and DT measurements LCD screen - 320x240 dots (monochrome) RS 232C interface Dimensions, weight 176x280x80 mm, 3 kg Power supply: +12V, 230B
MNIPI
Minsk
Produced in: Belarus, Minsk
Optical Transceiver Gigabit Ethernet/Fiber channel (1.25Gbps)
Optical Transceiver Gigabit Ethernet/Fiber channel (1.25Gbps)
from 686 ₽
Optical transceivers are in standard SFP metal cases with a combined optical input/output for SC, LC connectors for transmitting a signal over a communication line - one optical fiber.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Universal frequency meter Ch3-95
Universal frequency meter Ch3-95
The frequency meter is capable of operating both autonomously and as part of automated measuring systems with interfaces such as BUSB, RS-232, ETNET and IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (37.5 – 78.33) GHz Pulse duration 5 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng Setting range of trigger levels (inputs A, B) from -2 to 2 V The error of setting the trigger levels (inputs A, B) ± 0.01 V Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 10.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) 0.5 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 24 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x130,5x433 Weight, not more than 8.5 kg
Produced in: Moscow
SAC1000 Lenses
SAC1000 Lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 5.8±0.02 Height, mm: 1.5±0.02 Thickness, mm: 1.0±0.01 Refractive index, mm: 1.823 Pitch, mm: 1.0 Radius, mm: 6.52 Effective focal length, mm: 8.01 Rear focal length, mm: 7.45 Transmission, %: >99.5 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: 0.056 Surface quality at λ = 633 nm: λ/4 Residual deviation at full angle FW1/e2 (for non-linear deviation of the laser diode), mrad: 12.5
INZHEKT
Saratov
Produced in: Saratov
Power supply B5-78
Power supply B5-78
Technical specifications: B5-78 (15 V, 3 A); B5-78/1 (30 V, 2 A); B5-78/2 (50 V, 1 A); B5-78/4 (20 V, 1.5 A); B5-78/6 (30 V, 4 A); B5-78/7 (50 B, 2.5 A) Voltage measurement error: ±0.3 V Current measurement error: ±(0.04–0.06) A Voltage instability when the load current changes 0.03% Instability of the current when the voltage changes at a load of 0.2% Voltage ripple 0.5–1 mV Current ripple 0.1% Power consumption 90 - 320 VA Two 3-digit indicators (voltage, current) Adjustments are rough, smooth Dimensions 115x185x360 mm Weight: 3.7 kg (B5-78, B5-78/1, B5-78/2) 3 kg (B5-78/4) 5.5 kg (B5-78/6, B5-78/7) Power supply ~220 V A
MNIPI
Minsk
Produced in: Belarus, Minsk
A set of measures of electrical resistance H2-2
A set of measures of electrical resistance H2-2
Designed for storing and transmitting the size of a resistance unit, as well as for checking and calibration of working resistance measures and complex resistance meters with a four-pair or five-clamp connection scheme in the frequency range from DC to 10 MHz. Description: Each of the resistance measures H2-2 is a precision resistor, in series and in parallel to which fitting resistors are connected, placed in an aluminum housing. The measures have a four-pole connection scheme. Four BNC type connectors (plugs) are located on the wall of the housing. The distance between the connectors is 22 mm. In measures of 100 kOhm and 1 mOhm, it is possible to adjust the value of the time constant of the measure using a tuning capacitor.
MNIPI
Minsk
Produced in: Belarus, Minsk
PKV-IB-5,2×2,6
PKV-IB-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency meters H3-88
Frequency meters H3-88
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 2500 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz Counting time: input A, C – 1, 10, 102, 103, 104 ms; login to – (16•1), (16•10), (16•102), (16•103), (16•104) ms The number of averages. the period of the. vx. signal - 1, 10, 102, 103, 104 Timestamp period – 10-7, 10-6, 10-5, 10-4, 10-3 Borehole measurement at inputs A, C – 1.000001- 999999999 Frequency ratio in channels: A/S and C/A - 0.0001- 999999999; B/S - 0.5 – 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 5•10-8 - for 30 days, ± 10-7 - for 12 months 9 decimal places Overall dimensions (HXHL) - 285x106x345 mm Weight: 4 kg Reference generator: 1x10-7 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk