Search

696 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 203
    Names
    Loading...
  • 44
    Manufacturer
    Loading...
  • 29
    Made in
    Loading...
  • 34
    Additional
    Loading...
View:
696 products
Signal generator of a special form G6-49
Signal generator of a special form G6-49
General characteristics: USB 2.0 interface, SCPI support Power supply ~ 230 V, 35 V*A Operating temperature range from minus 10 C to + 40 C Dimensions; weight 325×270×125× mm; 4 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
General characteristics: LCD screen 12.1" with a resolution of 1024 x 768, keyboard, mouse. USB, Ethernet. Supply voltage: 230 V / 50 Hz, power: 450 V·A. Operating temperature range: from +5° to +40°C. Dimensions (W x H x D): 470 x 330 x 570 mm, weight: 37 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
AF18-30dB
AF18-30dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, dB 30 Attenuation error, dB ± 1.5 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
Digital oscilloscope S8-52
Digital oscilloscope S8-52
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 120 MHz. Technical specifications: Number of channels 2 120 MHz bandwidth Sampling rate 250 MHz Equivalent sampling rate of 10 GHz Rise time of PH <= 2.9 ns Input active resistance (1±0.02) Mom Input capacitance <= 25 pF 120 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 250 Mbps, in real time Recording length up to 16K counts in each channel Color LCD screen with LED backlight Cursor and automatic measurements USB and RS-232 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Oscilloscope S1-167/2
Oscilloscope S1-167/2
Designed for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0 - 25 MHz with a built-in multimeter measuring voltage and DC power, the average square value of voltage and AC power, DC electrical resistance. Technical specifications: Vertical deviation Number of channels 2 Bandwidth 0-25 MHz Deviation coefficients 2 mV/div-10 V/div (step 1-2-5) Installation error ± 3% Rise time of PH <= 14 nsec Input impedance 1 mOhm/23 pF, with divider 1:10-10 mOhm/12 pF with open input <=110 V with closed input <=110 V with divider 1:10 <= 250 V range U post. U AC: 1 mV–500 V Error 0.1% (U post); 0.3% -1% (U perem. 40 Hz–100 kHz) Range I post., I AC.: 1 mA–2 A Error: 0.25% (I post.); 0.5% (I perem. 40 Hz–5 kHz) R Range: 1 Ohm–1 mOhm Error R: 0.2% 3.5-digit indicator Automatic selection of limits.
MNIPI
Minsk
Produced in: Belarus, Minsk
MTP-01 Magnetic Coating Thickness Gauge
MTP-01 Magnetic Coating Thickness Gauge
from 75 000 ₽
Measuring range of thickness of protective coatings, mm: from 0.2 to 10 Digital display of measurement results: yes Power supply: from a PP3 type battery with a voltage of 9V Power consumption, MW: 100 Operating mode setting time, min: 1 Time of one measurement, sec: 3 Memory capacity, number of thickness values: 2000 Overall dimensions, mm: - electronic unit (width-depth length) 120x60x25 - measuring transducer (diameter height) 33x23 - connecting cable (length) 1500±300 Weight, g, no more: - electronic unit (without battery power) 80 - measuring converter 40 The kit includes: - Electronic unit, - Measuring converter - Plate made of non-magnetic material for setting the upper limit of measurements - Battery type PP3 - CD-ROM with the program - Prism - Cover - Spring - Case - Passport - Operation Manual
Produced in: Moscow
VD-12NFP Eddy Current Flaw Detector with 2 converters
VD-12NFP Eddy Current Flaw Detector with 2 converters
from 254 000 ₽
The device allows you to detect surface defects like cracks, visualizing the signal from the continuity interruptions on the display. The design of the flaw detector allows to determine with high reliability the exact location and depth of defects even on rough surfaces of flat and curved shape, including under a layer of corrosion or in the presence of a protective coating of the controlled area of the product with a thickness of up to 3 mm. The principle of operation of the VD-12NFP eddy current flaw detector: The principle of operation of the VD-12NFP eddy current flaw detector is based on the phenomenon of electromagnetic induction. An alternating magnetic field created in the primary coil of the converter by means of a sinusoidal voltage generator excites eddy currents in the controlled product. A parasitic magnetic field formed by eddy currents at the locations of defects affects the measuring unit (two signal coils connected in series) of the converter, creating an electromotive force in it. The amplitude and phase of the secondary signal carries information about the properties of the defect and the position of the transducer relative to the surface of the controlled product. The output signal from the measuring unit of the converter, after amplification and processing using a microprocessor, is displayed on the readout of the device, and is also stored in the memory block for subsequent transmission to a personal computer. In addition, information about the defects is displayed on a piezoelectric bell used as an audio indicator. Design, features and advantages of the VD-12NFP eddy current control device: The VD-12NFP eddy current flaw detector is a portable device capable of working both in a desktop and in a suspended position in a special bag-case. This ensures convenient operation of the device in a variety of conditions: in the laboratory, in the factory shop or during field tests. The flaw detector consists of an electronic unit with controls and display of test results, as well as three replaceable converters with wear-resistant corundum tips connected to the electronic unit using a connector. The choice of the desired converter depends on the magnetic properties of the material. For the control of parts with grooves, a converter with an inclined tip is offered. The device is powered by 4 AA batteries located in the battery compartment of the electronic unit. The advantages of the flaw detector include: - a screen for visualizing the signal during measurement; - light weight and compact dimensions that allow you to use the device in almost any conditions; - the ability to control the quality of products of various curvature and surface roughness even in the presence of a protective coating or a layer of corrosion; - wear resistance of converters, which is important when monitoring products with increased surface roughness (up to Rz£320); - automatic detection of the type of converter when connected, as well as the presence of built-in memory for storing control results; - the possibility to transfer data to a personal computer for storing or printing control protocols. Scope of application: Portability, high productivity, the ability to work with curved and rough surfaces, as well as the fact that the operation of the flaw detector is practically unaffected by humidity, pressure and contamination of the gas environment or the surface of the controlled product with non-conductive substances ensure the versatility of the device for detecting cracks in various materials. The eddy current flaw detector VD-12NFP is actively used in heavy industry for diagnostics of metal structures, assemblies and mechanisms for various purposes in factory workshops or laboratories, including at enterprises of railway transport, automotive industry, mechanical engineering, pipelines and metal structures. The VD-12NFP flaw detector can be used with equal success in the field, factory workshops, depots, laboratories and workshops to monitor the current condition, as well as to assess the degree of wear, the possibility and duration of further operation of such products made of metals and alloys as over-spring beams, wagon wheels, auto coupler housings, side frames, wheel couples and others. Distinctive features: • control of parts with surface roughness up to Rz320 due to wear-resistant corundum tips; • assessment of the degree of danger (depth) of the defect; • automatic detection of the converter type; • microprocessor control; • 5 universal programs for saving settings; • capable of detecting defects with a depth of 0.3 mm • The angle of deviation of the converter from the normal to the working surface up to 60° • Operating frequency of 70 kHz; • Maximum working clearance of 3mm; • visualization of the signal from the defect; • built-in memory for storing control results • Equipped with a Bluetooth 2.0 wireless communication module, which allows you to transmit control results and control the flaw detector at a distance of up to 20m; • The possibility of forming a control protocol based on the data transmitted to the PC; • Temperature range from 0°C to +40°C; • The design allows you to work with the flaw detector without removing it from the bag-case. Basic kit: Ia5.173.016: 1 electronic unit Ia5.125.031: 1 converter, type 1; marked as (•) Ia5.125.030: 1 converter, type 2; marked as (••) Ia2.706.002: the KOIDZ-VD set of samples with a passport (consisting of: Ia8.896.034: 1 piece; Ia8.896.035: 1 piece; Ia8.896.035-01: 1 piece) - A certificate of verification. 4 AA batteries 1 charger 1 small-sized phone 1 CD with software 1 special key 1 bag-case A calibration certificate is issued for the VD-12NFP flaw detector. 1 passport 1 operating manual 1 calibration instruction
Produced in: Moscow
Picoammeter A2-4
Picoammeter A2-4
System meter of small currents. The device allows to make measurements in almost the entire range of currents. The picoammeter is characterized by high performance, which is important for its use as part of automated measuring systems. Technical specifications: Current measuring range 1x10-14 - 1x10-2 A Error for the range 10-11, 10-10 ±[0.5+0.025(lk/lx-1)]% for the range 10-9, 10-8 ±[0.25+0.01(lk/lx-1)]% for the range 10-7, 10-6,10-5, 10-4,10-3, 10-2 ±[0,1+0,01( lk/lx-1)]% The time of setting the readings is 2x10-2 - 2x10-5 s Supply voltage 230 (±20) V, frequency 50 (± 0.5) Hz Power consumption 10 VA Overall dimensions (HxWxD) 105x284x366 mm Weight 3.5 kg Operating temperature 5 - 40 °C Humidity 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
FNCH-53
FNCH-53
These LFS can be used in conjunction with waveguide bandpass filters to increase the suppression of spurious signals and expand the upper band of the barrier. Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Bandwidth Fh-Fb at the level of -1 dB, GHz 45-53.6 The barrage band at the level of -30 dB, GHz 60-78 Bandwidth loss, 0.5-1.0 dB
Produced in: Moscow
IPEP-1 Electrostatic Field Parameter Meter
IPEP-1 Electrostatic Field Parameter Meter
Designed to measure the potentials of electrostatically charged objects, the strength of the electrostatic field and the surface density of electric charges. Technical specifications: Measuring range 0.02-50 kV The error is 5-10% The intensity of the electrostatic field Measuring range 2-1000 kV/m Error 5% Surface density of electric charges Measuring range 0.02-10 µcl/m2 Error 5% Measurement of the electrostatic field strength (2-1000 kV/m) Measurement of the potential of charged objects (0.02–50 kV) Measurement of surface charge density (2x10-8–1x10-5Kl/m2) Measurement error ±(5-10) % Laser pointer of the distance to the object (2, 10 cm) 3.5-digit indicator (LCD with image flip) RS-232C interface Dimensions, weight 40x106x268 mm, 0.7 kg Built-in battery for 8 hours of operation Power supply: ~220, 5 VA, 4.5–5.5 VA battery
MNIPI
Minsk
Produced in: Belarus, Minsk
PKV-IP-5,2×2,6
PKV-IP-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow