Chromatograph Milichrome A-02
Chromatograph Milichrome A-02
Overall dimensions: 550x230x350 mm Weight (without computer): ~17 kg Power consumption: up to 200 watts Warranty service : 1 year   Detector Two-beam spectrophotometer Spectral range – 190-360 nm Simultaneous detection at 1-8 wavelengths Cell volume – 1.2 µl Noise <0.0001 E.O.P. at 250 nm Drift <0.00005 E.O.P./hour at 250 nm Column Ø2x75 mm stainless steel The efficiency of the column is up to 6000 theoretical plates Thermostat Solid-state electric Set temperature from 35 to 90°C The discreteness of the temperature setting is 1 °C Temperature control error ±0.3°C      Pump Two-pronged, gradient The feed rate is from 5 to 1000 µl/min, the maximum pressure is 70 atm . The gradient is formed from 1 to 20 linear sections Automatic doser Automatic, programmable Number of test tubes – 46 The number of analyses in the series is from 1 to 200 The dosed volume is from 1 to 99 µl Test tubes made of glass with a volume of 200 µl Polyethylene tube stoppers Software OS: Windows® XP/7/10 Milichrome A-02™, Multichrome™, Alphachrome, Alphaspectrum
EkoNova
Novosibirsk
Produced in: Novosibirsk
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg