Reflection prefix PO-15 V
Reflection prefix PO-15 V
Designed for the study of various types of solid samples, including optical and semiconductor materials, precious stones and other objects of arbitrary shape • The sample is located on the subject plane of the investigated surface downwards, the angle of incidence of the central beam on the sample is 15 ° • Allows you to examine samples of small sizes (the diameter of the test area is from 1 mm) • The set-top box is equipped with a set of replaceable diaphragm holders for samples of different sizes • When using a mini-press, it allows you to examine samples in the form of a thin layer rolled out on a mirror plate made of alloy steel (radiation passes through the substance layer twice, reflecting from the mirror surface) • Not used: for the study of bulk and liquid substances
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Mold for the manufacture of tablets with KBr diameter of 13 mm
Mold for the manufacture of tablets with KBr diameter of 13 mm
It is intended for the preparation of samples in the form of compressed tablets consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). The mold is used in combination with the hydraulic press GP 200-13. - the mold is made of high-quality alloy hardened steel - to obtain better compressed tablets with KBr, the mold can be pumped out using a pre-vacuum pump. The customer can purchase the pump independently, or order it from the NPF “SIMEX”. Pumping out the mold is not necessary for most studies. - the kit includes a special dispenser for placing the optimal amount of the pressed mixture in the mold - to install the finished samples in the spectrometer, a holder of KBr tablets and D13mm substrate windows is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Universal holder of solid samples of various thicknesses and films
Universal holder of solid samples of various thicknesses and films
It is used for recording transmission spectra of medium–sized and arbitrary-shaped solid samples - polymer films of various thicknesses, optical parts, semiconductor wafers, large crystals, etc. • Thanks to quick-release nuts, it provides convenient fastening of samples
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Infrared Fourier spectrometer "InfraLUM® FT-08"
Infrared Fourier spectrometer "InfraLUM® FT-08"
Technical specifications: Operating spectral range, cm-1 from 400 to 7800 Spectral resolution, cm-1, not more than 0.7 The limit of the absolute error of the wavenumber scale, cm-1 ± 0.05 Signal-to-noise ratio (RMS) for the wavenumber 2150 cm-1, determined in the range ± 50 cm-1 for a resolution of 4 cm-1 and an accumulation time of 60 s, at least 40,000 The limit of deviation of the 100% transmission line from the nominal values for the wave number 2150 cm-1, determined in the range ± 50 cm-1, % ± 0.2 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system, % ± 0.25 The time of setting the operating mode of the spectrometers, h, no more than 2 Continuous operation time of spectrometers, h, not less than 8 Power consumption, In × A, not more than 65 Overall dimensions, mm, not more than 580x550x340 Weight, kg, not more than 32 Average time to failure, h, not less than 2500 Average service life of the spectrometer, years, at least 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
PRIZ - a reflection prefix with the lower position of the sample and visualization of the object under study on the monitor
PRIZ - a reflection prefix with the lower position of the sample and visualization of the object under study on the monitor
The main advantage of the PRIZ prefix is the possibility of obtaining well–defined spectra of micro-objects after giving them the shape of a thin layer on mirror-polished metal plates (in the mode of the so-called double passage, when radiation twice penetrates through the layer of matter, reflecting from the mirror-substrate). The presence of a visual control system with a built-in video camera significantly increases the information content when setting up and the reliability of the results obtained. With the help of the prefix, it is also possible to register the reflection spectra of bulk samples and solid objects of arbitrary geometry in native form, including pharmaceuticals in the form of tablets, powders and granules, polymer fragments, LCP, films deposited on the surface. Technical specifications Transmission in the operating range of the spectrum, % of the input signal at least 40 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 Minimum initial dimensions of a solid sample, mm 0.2 × 0.2 The maximum area of the solid sample, mm 20X20X10 Variable focus range, mm 10 The diameter of the focus spot, mm 3 The angle of incidence of radiation (central beam) on the sample in the ZDO 45o mode Micro lens magnification / total magnification of the 4X visual channel Field of view of the optical system, mm 2 X 2.5 The resolution of the digital video camera is 640x480 Overall dimensions, mm 140×105×160 Weight, kg 1.16
SIMEKS
Novosibirsk
Produced in: Novosibirsk
IR Laser Module KLM-D980-x-5 980nm
IR Laser Module KLM-D980-x-5 980nm
Laser modules of the KLM-D980-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Hydraulic press GP 200-13
Hydraulic press GP 200-13
Designed for the preparation of samples in the form of compressed tablets with a diameter of up to 13 mm, consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). - the principle of operation of the press is based on the injection of pressure in the hydraulic system by swinging the lever. - to control the working pressure, the press is equipped with a pressure gauge - complete with a press, molds with a diameter of 13 mm and 3.5 mm can be used - for the study of finished samples on a Fourier spectrometer, a KBr tablet holder and D13mm substrate windows or a microfocusing attachment (for 3.5 mm tablets) is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
IR microscope "MIKRAN"
IR microscope "MIKRAN"
The IR microscope "MIKRAN" is designed to work with IR Fourier spectrometers "Infralum FT-801". The spectral range is 6000 – 600 cm-1 (with a microscope and an MST detector cooled with liquid nitrogen). Resolution 0.5, 1, 2, 4, 8 cm-1 (determined by the resolution of the Fourier spectrometer)
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Infrared Laser 980 nm KLM-980-x
Infrared Laser 980 nm KLM-980-x
CDL lasers of the KLM-980 series are optimal sources of continuous radiation for the construction of control and automation systems, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
MNPVO prefix with a zinc selenide element and an integrated visualization system on an external monitor
MNPVO prefix with a zinc selenide element and an integrated visualization system on an external monitor
The main difference between this set-top box and the universal set-top box of the NPVO and ZDO is that a prism is used as a working element of the MNPVO, which allows to obtain several reflections from the area of contact with the sample under study, which leads to an improvement in the quality of the spectrum and an increase in the sensitivity of the method (absorption bands become more pronounced). The registration of specular and diffuse reflection spectra (ZDO) is not provided on this set-top box. The MNPVO prefix is effective in registering the absorption spectra of samples whose dimensions (number) are sufficient to ensure contact with the entire area of the working face of the prism: * liquids of any degree of viscosity (solutions, suspensions, oils, etc.); * solid elastic samples (polymer fragments of sufficiently large size, rubbers, plastics, etc.); * powdered samples in quantities sufficient to be applied to the entire surface and samples in the form of thin tapes; The universal clamp is equipped with a precision lever mechanism for quickly lowering the tip and a micrometer screw that allows you to pre–set the optimal degree of pressure - this ensures quick sample change and repeatability of the results during measurements. For convenience when working with liquid and paste-like samples, it is possible to rotate the clamping console by 180o. Note: the MNPVO prefix does not exclude the possibility of registering the spectra of samples whose dimensions are smaller than the area of the working face of the prism (the presence of a visual inspection system of the surface under study increases convenience when working with small-sized objects), but the overall effectiveness of the method is significantly lower than when using the universal NPVO and ZDO prefix. Transmission in the operating range of the spectrum, % of the input signal of at least 25 · The recommended number of scans when registering spectra is 25 · Spectrum registration time at 25 scans (resolution 4 cm-1), 30 seconds · The depth of penetration of radiation into the sample, microns 5 – 15 · Minimum area of a solid sample, mm2 1 · Minimum volume of the test liquid, ml 0.3 · The permissible pH range of the analyzed objects is from 5 to 9 · Crystal substrate material ZnSe CVD, Ge · Diameter of the focus spot, mm 3 · Number of reflections 3 · The size of the working face of the prism, mm 21 X 6 · Magnification of the 4X micro lens · Total magnification of the visual channel 75X · Field of view of the optical system, mm 2 X 2.5 · Digital video camera resolution 640 X 480 · Overall dimensions, mm 145×125×240 · Weight, kg 2
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Liquid collapsible cuvettes
Liquid collapsible cuvettes
They are used for the study of liquids, including solutions with low concentrations • Have a collapsible design that allows you to use the supplied gaskets of different thicknesses • Window material – ZnSe (it is possible to order windows from SiO2 and KBr) • Gasket material – Teflon (fluoroplast) • Thickness of gaskets – 0.022 mm, 0.1 mm, etc.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
NTEGRA NANO IR
NTEGRA NANO IR
NT-MDT Spectrum Instruments is an INTEGRA Nano IR–scattering scanning near‑field optical microscope (s-NSOM) designed for the infrared spectral range. The AFM probe is located in the focus of an optical system that directs the IR laser radiation to the sample and collects the optical response. The collected radiation is sent to the Michelson interferometer for optical analysis. The far-field component of the collected signal is suppressed by synchronous detection. The INTEGRA Nano IR system allows detecting the amplitude and phase of the near-field signal. The spatial resolution of the resulting reflection and absorption contrasts is approximately 10 nm and is determined only by the size of the tip of the probe.
Produced in: Moscow, Zelenograd