Atomtekh

Atomtekh

49 products
View:
Telephone number:
Website: atomtex.com
Address:
Belarus, Minsk
Website: atomtex.com
Address:
Belarus, Minsk
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • 6
    Names
  • 1
    Manufacturer
  • 2
    Made in
  • 1
    Additional
View:
47 products
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
Measurements in wide ranges of capacities doses and energies Measurement of dose rate and duration of exposure during short-term radiation from 0.03 s Measurement of the average dose rate of pulsed radiation with a pulse duration of 10 ns (AT1123) The possibility of remote measurements using a remote control The possibility of stationary location with external audible and visual alarms with "dry" contacts for controlling actuators The possibility to connect to a PC for organizing a continuous monitoring system with a documentation function
Produced in: Belarus, Minsk
RADIATION PEDESTRIAN MONITOR MPP‑AT930
RADIATION PEDESTRIAN MONITOR MPP‑AT930
▪ Rapid adaptation to changes in the radiation background ▪ Audible and light alarms when gamma radiation is detected ▪ Mobility and the possibility of forming passages ▪ Self-control of components in the process of work ▪ The possibility of continuous or episodic radiation monitoring ▪ The possibility to work from a 230V, 50Hz network or from a built-in rechargeable battery Compliance with the international standard IEC 62244:2006 Stationary radiation monitors for the detection of radioactive and special nuclear materials at state borders
Produced in: Belarus, Minsk
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
Detection of gamma and neutron radiation sources in the flow of pedestrians crossing the border of the controlled object. Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software High reliability and self-control Backup power supply At the request of the user, the MCI can be supplied without a neutron channel.
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
Measurement of the power of the ambient dose equivalent and the ambient dose equivalent of neutron radiation, as well as simultaneous monitoring of the power of the ambient dose equivalent and the ambient dose equivalent of gamma radiation. A wide energy range Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4 Audible and visual alarm of exceeding threshold levels
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
High sensitivity Sound, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions A wide range of measurements
Produced in: Belarus, Minsk
 INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
Control of individual radiation doses from X-ray and gamma radiation. Together with the reader and software, they form an effective system for automated control of dose loads on personnel. ▪ Simultaneous measurement of the power of the individual dose equivalent and the dose of gamma radiation ▪ Automatic compensation of the detector's own background ▪ The mode of signaling the presence of pulsed radiation with a duration of 10 ns (optional)
Produced in: Belarus, Minsk
DOSIMETER DKS‑AT5350/1
DOSIMETER DKS‑AT5350/1
A high-precision dosimeter with extensive functionality: measurement of DC power, electric charge, charge by numerical integration of current, kerma and kerma power in the air, kerma by numerical integration of kerma power and other radiological quantities. Composition of the dosimeter: - Electrometric measuring unit (electrometer) - PTW-Freiburg ionization chambers (Germany) to choose from: TM23342 Flat-parallel X-ray (volume 0.02 cm3) TM31010 Cylindrical (volume 0.125 cm3) TM30010 Thimble (volume 0.6 cm3) TM23361 Cylindrical (volume 30 cm3) TM32002 Spherical (volume 1000 cm3)
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
High sensitivity Audible, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4
Produced in: Belarus, Minsk
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
Storage and transfer of kerma units in the air, ambient, individual and directional dose equivalents and their X-ray radiation capacities to working standards and measuring instruments. ▪ The use of highly stable ISOVOLT X-ray machines with metal-ceramic tubes ▪ Field shaper with radiation qualities according to GOST 8.087, ISO 4037, IEC 61267, etc. ▪ Replaceable discs with 11 filter slots; 3 replaceable diaphragms ▪ Additional filters up to 50 mm thick ▪ A protective flap made of tungsten with beam attenuation of more than 1000 times and a response time of less than 0.1 s ▪ A camera monitor and an electrometric unit provide monitoring of the presence and stability of the radiation output ▪ A positioning system in the radiation beam along three axes ▪ A laser detector centering devices ▪ A video surveillance system of indications ▪ Alarm and blocking systems, radiation monitoring ▪ A control system using operator panels and PC
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
Measurement of the ambient dose equivalent or absorbed dose rate of gamma radiation in liquid media, wells, underground storage facilities and other hard-to-reach places Compatible with detection units: BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-17, BDKG-24, BDKG-30 Measurement at depths up to 30 meters Marking on the cable to determine the depth of immersion A Cable Winding Coil
Produced in: Belarus, Minsk
PULSE RADIATION MONITORING SYSTEM
PULSE RADIATION MONITORING SYSTEM
Logging data on dose rate levels and exceeding threshold levels Software that allows you to display on a PC monitor the current radiation situation at a controlled facility Backup power supply High radiation resistance – at least 50,000 Sv for UDKG-37 Failure diagnostics The possibility of using the system for dosimetric monitoring of both pulsed and continuous gamma radiation The possibility of using the DKS-AT1123 dosimeter autonomously as a wearable device
Produced in: Belarus, Minsk
RADIOMETER RKS‑AT1329
RADIOMETER RKS‑AT1329
The radiometer allows you to: - measure the total alpha and total beta activity of counting samples based on aerosol analytical filters of the AFA type; - measure the total alpha and total beta activity of "thick-layer" counting samples prepared from the sample substance (for example, by evaporation or by any other method that provides a "thick" sample); - measure the total alpha and total beta activity of "thin-layer" counting samples prepared from the sample substance (for example, by electrolytic deposition); - measure activity, flux density, external alpha and beta radiation for sources of type 1P9, 2P9, 3P9, 1C0, 2C0, 3C0; - control radiation contamination of surfaces by smears. Device control and measurement data processing is performed by an external PC The possibility to use custom calibrations The possibility to select units of measurement LED stabilization of the measuring path Passive lead protection against background radiation The possibility to maintain a measurement database Methodological support of measurements