VZOR

VZOR

32 products
View:
Telephone number:
Address:
Russia, Nizhny Novgorod, null, 33null
Адрес:
Russia, Nizhny Novgorod, null, 33null
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 5
    Applying
  • 9
    Names
  • 1
    Manufacturer
  • 2
    Made in
  • 1
    Additional
View:
32 products
MARK-603/1
MARK-603/1
Measurement of electrical conductivity (UEP, UEP20, UEP25), equivalent salinity according to NaCl, total salinity (TDS) and temperature of water and aqueous solutions in various industries and national economy. Control of chemical water treatment at thermal power facilities. Control of surface waters at a depth of up to 20 meters. Control of distilled water according to GOST 58144-2018 "Distilled water. Technical conditions". Control according to GOST 26423-85 "Soils. Methods for determining the specific electrical conductivity, pH and dense residue of water extract". 24-month warranty for deliveries across the Russian Federation IP65 The compact sealed device is reliably protected from dust and moisture Electronic notebook Ability to record up to 100 measurement groups in User-named folders Stainless steel Submersible sensor The ability to measure at a depth of up to 20m Graphic indicator with backlight Indication of readings in a user-friendly format Low power consumption Up to 600 hours of operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK® 01 MK
MARK® 01 MK
Cooling, throttling, filtration and regulation of sample flow. Indication of temperature, pressure and flow of the sample. Temperature, pressure and cooling water flow indication (optional). Sample preparation for water-chemical regime monitoring devices at energy facilities. Continuous monitoring of sample parameters and data transmission via digital and current outputs. Maintaining stable sample pressure. Alarm and automatic shut-off of the sample supply in case of violation of the regime. Custom temperature and pressure settings for automatic shut -off of sample supply. Pulse line purge valve. Compact stainless steel panel 350*944 mm. One-way service. Easy-to-clean collapsible heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH Analyzer MARK® 9010
pH Analyzer MARK® 9010
Measurement of the activity of hydrogen ions (pH, pH25) of "ultrapure" waters (including water with a reduced electrical conductivity of 0.055 microns /cm) and alkaline waters containing ammonia or amines. Measurement of electrical conductivity (UEP, UEP25), temperature of aqueous media. Control of water-chemical regimes at energy facilities. A new patented measurement method that does not require calibration. The absence of elements that degrade in "ultrapure" water. Convenience and accuracy of measurement | Automatic thermal compensation. Freely programmable measurement ranges. Measurement of conductivity in the range up to 30 microns/cm. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Relay of "dry" contacts (6 pcs.) with programmable functions. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. A single protective box that combines the secondary converter and the hydraulic part. Intelligent data processing algorithms. 5.7" graphic touchscreen display, 65535 colors, resolution 640*480 pixels.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK® 901
pH meter MARK® 901
Measurement of the activity of hydrogen ions (pH, pH25), ORP, EMF and temperature of aqueous media. Operational control of parameters of water-chemical regimes at thermal and nuclear power facilities, in accordance with CO 153-34.37.303. Convenience and accuracy of measurements | Automatic temperature compensation. Automatic recognition of buffer solutions. Four measurement modes | pH, pH25, EMF/ORP, temperature. pH measurement in flow and immersion modes | The flow-filling MPN 901/903 module is included. High contrast LCD indicator | Low power consumption | Up to 2000 hours of continuous operation from a set of AA elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK® 902 MP
pH meter MARK® 902 MP
Measurement of hydrogen ion activity (pH) and temperature of aqueous media. pH control of water media in technological processes, including treatment facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Calibration according to standard buffer solutions with their automatic determination. Universal trunk-submersible "active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409T Dissolved Oxygen Analyzer
MARK-409T Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones.Convenience and accuracy of measurement | The measurement error is ±(0.001 + 0.035 *A) mg/dm3, (A is the measured value). The ability to work on small flows (from 25 ml / min). Routine maintenance 1 time per year. Highly stable sensor | High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Hydropanel GP 409 T | The possibility of placing the measuring complex on a single panel. The supply lines are stainless steel. Routine maintenance and calibration of the sensor – without interrupting the flow. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
conductometer MARK® 602 MP
conductometer MARK® 602 MP
Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure", in the main and flow modes. Control of water-chemical regimes at thermal and nuclear power facilities, including control of cooling water suction in the turbine condenser.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 302 M
Oxygen meter MARK® 302 M
The sensor is designed specifically for BOD measurement according to the PNF F method 14.1:2:3:4.123-97. Convenience and accuracy of measurement | Automatic temperature and barocompensation. Automatic air oxygen calibration. Three measurement modes | KRK, mg/dm3. KRK, % saturation. Temperature, °C. Easy calibration by air | Minimum maintenance | Replacement of the membrane no more than once a year. Storage of the sensor in the air. Long-lasting sensor | The service life of the sensor is at least 10 years. High contrast LCD indicator | Low power consumption | Up to 2000 hours of continuous operation from a set of AA type elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK-904
pH meter MARK-904
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Laboratory measurements in various industries and national economy. 24-month warranty for deliveries across the Russian Federation Convenience and accuracy of measurement Automatic temperature compensation. Automatic recognition of buffer solutions. Self-diagnosis Non-volatile electronic notebook Ability to record up to 500 measurement groups in named The user of the folder. USB port, software included The ability to create and manage a data archive on a PC. Graphic indicator with backlight Indication of readings in a user-friendly format. Ease of settings.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 302 T
Oxygen meter MARK® 302 T
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Operational control of water-chemical regimes at thermal and nuclear power facilities.Convenience and accuracy of measurement | Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor | The service life of the sensor is at least 10 years. High contrast LCD indicator | Low power consumption | Up to 2000 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 409 A
Oxygen meter MARK® 409 A
Continuous measurement of dissolved oxygen concentration and temperature of aqueous media with excessive hydrostatic pressure.Two independent measurement channels Freely programmable measurement ranges Stability of operation with changes in hydrostatic pressure Permissible short-term (up to 5 min) pressure overload (water hammer) up to 40 MPa High reaction speed. The time to establish the analyzer readings is 2 minutes. Easy and quick replacement of the membrane The sensor is not afraid of "drying out" The content of dissolved hydrogen in the analyzed medium is taken into account The grading interval is 1 month The verification interval is 24 months
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
conductometer MARK® 1102
conductometer MARK® 1102
Measurement of specific electrical conductivity (UEP, UEP25) and mass fraction (C) of solutes (NaCl, NaOH, HNO3, H2SO4, HCl) in water. Control of water-chemical regimes at thermal and nuclear power facilities.Contactless inductive sensor resistant to aggressive environments | Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings. Submersible, trunk, flow fittings |
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod