High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
Generator G6-46
Generator G6-46
Technical specifications: Frequency range, from 0.1 Hz to 1 Frequency range, from 0.1 Hz to 1 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span)Smooth signal attenuation, at least 20 dB Frequency stability in 15 minutes, no more than 0.5% Hz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span) Smooth signal attenuation, at least 20 dB Frequency instability in 15 minutes, no more than 0.5 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply B5-86, B5-86/1
Power supply B5-86, B5-86/1
Main Features: Output voltage indication error, ± 0.3 V Output current indication error, ±0.06 A Instability of the output voltage due to changes in the supply voltage, 0.05% Instability of the output current from a change in the supply voltage, 0.2% Instability of the output voltage when the load current changes, 0.1 % Instability of the output current when the load voltage changes, 5.0 % Output voltage ripple, mV 1.0
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeters B7-91, B7-91/1
Voltmeters B7-91, B7-91/1
Technical specifications: DC voltage , Measuring range, 10 MV - 1000 V Measurement error, ± 0.03% AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± 0.4% Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 1 mkA - 2 A (B7-91/1) Measuring range, 1 mkA - 20 A (B7-91) Measurement error, ± 0.03%
MNIPI
Minsk
Produced in: Belarus, Minsk
Oscilloscope S1-176
Oscilloscope S1-176
It is intended for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0-50 MHz, as well as for monitoring the parameters of two- and three-pole devices using a component tester. Technical specifications: Number of channels 2 Bandwidth 0 - 50 MHz Deviation coefficients of 2 mV/div - 20 V/div (step1-2-5) Installation error ± 3%, ± 4% with a 1:10 divider Rise time of PH <= 7 nsec Input impedance is 1 mOhm/25 pF, with a divider of 1:10 - 10 mOhm/23 pF Harsh operating conditions (-10°C to +40°C) Bandwidth 0 - 50 MHz Two channels Indication of deviation and sweep coefficients on LED matrices Tenfold stretching of the sweep Calibrator 0.6 V, 1 kHz (± 1%) X-Y mode Built-in Component Tester Screen 80x100 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Educational laboratory complex KUL-1
Educational laboratory complex KUL-1
It is intended for use in higher and secondary educational institutions during laboratory workshops on training specialists in engineering and technical specialties and natural science disciplines. Technical specifications: Upost.- 0.1 mV - 500 V; Uperem.- 1 mV-300 V (40 Hz-20 kHz) Ippost. - 0.1 mkA- 2 A; Iperem. - 1.0 mkA - 2 A (40 Hz-1 kHz) Rpost. - 0.1 Ohm – 20 mOhm Generation of triangles, pilobr., "meander", sinusoid. signal in the frequency range 0.1 Hz – 1 MHz Frequency measurement in the range of 0.1 Hz – 1 MHz The form of the measured signals is sine, pulse Constant voltage: at a current of 1 A - + 5 V at a current of 0.5 A for each channel - ± 12 V Adjustable Uppost. at a current of up to 1 A - 0 – 30 V Dimensions - 170x340x380 mm Power supply – 230 V, 50 Hz, 200 VA - max. Weight – 8.0 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Digital oscilloscope S8-52
Digital oscilloscope S8-52
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 120 MHz. Technical specifications: Number of channels 2 120 MHz bandwidth Sampling rate 250 MHz Equivalent sampling rate of 10 GHz Rise time of PH <= 2.9 ns Input active resistance (1±0.02) Mom Input capacitance <= 25 pF 120 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 250 Mbps, in real time Recording length up to 16K counts in each channel Color LCD screen with LED backlight Cursor and automatic measurements USB and RS-232 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-61
Measuring antenna P6-61
Technical specifications: Frequency range (26.0 - 300) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 145x75x1720 mm Weight 0.7 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
IR-11 radioactivity indicator
IR-11 radioactivity indicator
It is designed to detect local areas of radioactive contamination on the ground, in residential and working premises, measure the dose rate of gamma radiation, the accumulated dose for a period set by the user, and an audible alarm of exceeding the threshold of the dose rate of gamma radiation set by the user. Technical specifications: measurement of the power of the equivalent (exposure) dose of gamma radiation in the range from 0.1 to 999 mSv / h with the presentation of the results on a digital indicator measurement of the accumulated radiation dose from the moment of switching on, as well as from the moment of a special reset operation to zero, after which a new cycle of dose accumulation is carried out while the device is switched off. The maximum indicated value of the accumulated dose is 999 mSv signaling the excess of one of the user–selected threshold power levels of the equivalent (exposure) dose of 0.5; 1; 2 and 5 mSv/ h with an intermittent sound signal , the alarm time for exceeding the threshold level is not more than: - for the threshold level of 0.5 and 1 mSv/ h – 60 s - for threshold levels 2 and 5 mSv/h - 10 s the energy dependence of the device readings is not more than ± 45% in the energy range from 0.05 to 1.5 MeV the time of setting the operating mode is not more than 10 s the supply voltage (3.3-2.4) V the consumption current when registering the natural radiation background is not more than 0.35 mA and not more than 20 mA when registering exceeding the threshold level of 5 mSv / h the continuous work when registering the natural radiation background without changing batteries for at least 25 days the overall dimensions of the device are not more than 70 x 137 x 25 mm and not more than 85 x 150 x 40 mm with packaging the weight of the device is not more than 150 g without packaging and not more than 200 g with packaging working conditions of use: - ambient temperature from + 5 to + 40 ° C - relative humidity up to 80 % at a temperature of 35 ° C
MNIPI
Minsk
Produced in: Belarus, Minsk
Digital oscilloscope C8-39
Digital oscilloscope C8-39
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Technical specifications: Vertical deviation :2 Number of channels 0-50 MHz Rise time of PH ≤ 7.0 ns Input impedance 1 ± 0.03 mOhm, 25 pF Deviation coefficients of 5 mV/div - 2 V/div (step 1-2-5) The maximum input voltage is 100 V With a divider of 1:10 250 V The error of amplitude measurements is a≤ 2 % 5 mV...2 V; 10 ns...2 s/del. ADC: 2 channels, 50 MHz, 8 bits Equivalent sampling rate of 2.5 GHz Marker measurements U: ±2.5%, T: ±1.5% Pre-launch 8 screens, post-launch 150 screens Simultaneous observation of 2 signals Cursor measurements DU and DT Averaging modes and automatic DU and DT measurements LCD screen - 320x240 dots (monochrome) RS 232C interface Dimensions, weight 176x280x80 mm, 3 kg Power supply: +12V, 230B
MNIPI
Minsk
Produced in: Belarus, Minsk
Universal calibrator H4-301
Universal calibrator H4-301
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range UK 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, Uk 2; 20 V 0.15 + 0.02 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V from 20 Hz to 20 kHz Basic error, ± (% of U + % of Uk): sv. 20 to 40 kHz 0.2 + 0.1 Uk 200 V; 600 V: from 40 Hz to 1 kHz 0.2 + 0.05 Power reproduction range Ik 200 Ma 0.1 + 0.02 DC: from 1 Ma to 5 A, Ik 2; 20; 200 mA 0.1 + 0.01 sub-bands (Ik) 200 Ma; 2; 20; 200 mA; 2; 5 A Ik 2 A; 5 A 0.1 + 0.02 Basic error, ± (% of I + % of Ic): AC power reproduction range: from 10 Ma to 5 A sub-bands (Ic) 200 Ma; 2; 20; 200 mA; 2; 5 A 0.15 + 0.05 Frequency range from 20 Hz to 1 kHz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 °C to + 50 °C Dimensions; weight 420×342×184.5 mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply B5-89, B5-89/1
Power supply B5-89, B5-89/1
Technical specifications: Indicator name, unit of measurement, Indicator value, B5-89, B5-89/1 The range of the output voltage setting, the limits of the absolute error of the output voltage setting:- basic error, In; - in operating conditions, In, from 0 to 30.0 ± 0.2± 0.3, from 0 to 100.0 ± 0.3± 0.45 The range of the output current setting, the limits of the absolute error of the output current setting:- basic error, A; - in operating conditions, A, from 0 to 10.0 ± 0.2± 0.3, from 0 to 3.0 ± 0.1± 0.15 Instability of the output voltage when the supply voltage changes by ± 10% of the nominal value in the voltage stabilization mode, %, ± 0.05, no more, Instability of the output current when the supply voltage changes by ± 10% of the nominal value in the current stabilization mode, %, ± 0.2, no more, Instability of the output voltage when the load current changes at the output terminals of power supplies in voltage stabilization mode, %, ± 1, no more, Instability of the output current when the load voltage changes in the current stabilization mode at minimum load currents, %, ± 5, no more, Instability of the output current when the load voltage changes in the current stabilization mode at maximum load currents, %, ± 0.5, no more, Output voltage ripple in voltage stabilization mode, mV, 1.0, no more, Output current ripple in current stabilization mode, %, 1, no more, Instability of the output voltage from time, V, ± 0.5, ± 1.0 Instability of the output current from time, A, ± 0.3, ± 0.2 AC power supply: - voltage, V; - frequency, Hz, 230 ± 2350 ± 0.5, Weight, kg, 13.0, no more, Overall dimensions, mm, 384x301x169