Gosmetr

Gosmetr

142 products
View:
Telephone number:
Address:
Russia, Saint Petersburg, 58
Address:
Russia, Saint Petersburg, 58
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 3
    Applying
  • 1
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 2
    Additional
View:
54 products
Laboratory scales VLTE-410S
Laboratory scales VLTE-410S
from 74 990 ₽
Technical characteristics: NIP, G410 Discreteness, g 0.001 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the scale verification division, mg10 The limits of the permissible error during the initial verification, mgot 0.02 g to 50 g inclusive. ± 5; sv. 50 g to 200 g included. ±10; sv. 200 g to 410 g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-310P-V
Technical laboratory scales VLTE-310P-V
from 47 490 ₽
Technical specifications: NIP, g310 Discreteness, g0,005/(0.002)* Internal calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0,1 The limits of permissible error during initial verification, mgot 0.1g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-320S
Analytical scales VL-320S
from 214 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, seconds, no more - fast mode - 3; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty Price with VAT, rub214,990
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-2100T
Technical laboratory scales VLTE-2100T
from 27 490 ₽
Technical characteristics: NIP, G2100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2KGF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 77 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-220S-O
Analytical scales VLA-220S-O
from 359 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals:from 0.01g to 50g incl. ±0.5; sv. 50g to 200g incl. ±1.0; sv. 200g to 220g incl. ±1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 The alignment weight is built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-6100
Laboratory scales VLTE-6100
from 47 990 ₽
Technical specifications: NIP, g6100 Discreteness, g0,1 External calibration The size of the bowl / platform of the scales, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 6100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-224V-S
Analytical scales VL-224V-S
from 217 490 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ±1.0; sv 200 to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 Adjustment weight built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210S
Laboratory scales VLTE-210S
from 59 990 ₽
Technical characteristics: NIP, G210 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g on ±10; sv. 200g to 210g on ±15 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-101 platform scales
RUNWAY-101 platform scales
from 114 990 ₽
Technical specifications NIP, kg101 Discreteness, g5/(2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-120C-O
Analytical scales VLA-120C-O
from 329 990 ₽
Technical specifications: NIP, g120 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of the permissible error of the scales during verification, ± mg, weighing intervals: from 0.01 g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, not more than 7 Adjusted weights 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-32 platform scales
RUNWAY-32 platform scales
from 107 490 ₽
Technical specifications NIP, kg32 Discreteness, g0.5/(0,2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 20kg incl. ±1.0; sv.20kg to 32kg incl.± 1.5 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 10kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg