Technical laboratory scales VLTE-310P-V
Technical laboratory scales VLTE-310P-V
from 47 490 ₽
Technical specifications: NIP, g310 Discreteness, g0,005/(0.002)* Internal calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0,1 The limits of permissible error during initial verification, mgot 0.1g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-32 platform scales
RUNWAY-32 platform scales
from 107 490 ₽
Technical specifications NIP, kg32 Discreteness, g0.5/(0,2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 20kg incl. ±1.0; sv.20kg to 32kg incl.± 1.5 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 10kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-120C
Analytical scales VL-120C
from 174 990 ₽
Technical characteristics: NIP, G120 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 3;- standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-220S-O
Analytical scales VLA-220S-O
from 359 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals:from 0.01g to 50g incl. ±0.5; sv. 50g to 200g incl. ±1.0; sv. 200g to 220g incl. ±1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 The alignment weight is built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-320S
Analytical scales VLA-320S
from 349 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals: from 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 Adjustment weight built - in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
VAC-32 platform scales
VAC-32 platform scales
from 69 990 ₽
Technical specifications: NIP, kg32 Discreteness, g1,0 External calibration Size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 20kg incl. ±1.0; sv.20kg to 32kg incl.± 1.5 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustmen 10kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210S
Laboratory scales VLTE-210S
from 59 990 ₽
Technical characteristics: NIP, G210 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g on ±10; sv. 200g to 210g on ±15 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210/510
Laboratory scales VLTE-210/510
from 77 490 ₽
Technical specifications: NIP, g210/510 Discreteness, g0,001/0,01 External calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02/0.5 The price of the verification scale division, mg10/100 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5/±50; St. 50g to 200g incl. ±10/±50; St. 200g to 210g incl. ±15/±50; St. 210g to 500g incl. ±50; sv. 500g to 510g incl. ±100 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high The setting time, s, no more than ~3 /~2 Weight adjustment 200gF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-320S-O
Analytical scales VLA-320S-O
from 389 990 ₽
Technical specifications: NIP, g320 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification scale division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals: from 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of scales, kg, not more than 7 Adjustment weights built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
VAC-101 platform scales
VAC-101 platform scales
from 69 990 ₽
Technical specifications NIP, kg101 Discreteness, g10 External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-224V-S
Analytical scales VL-224V-S
from 217 490 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ±1.0; sv 200 to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 Adjustment weight built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-6202CI
Laboratory scales VLE-6202CI
from 204 990 ₽
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g1,0 The price of the verification scale division, mg100 The limits of the permissible error during the initial verification, mgot 1g to 5000g incl. ±50; sv. 5000g to 6200g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 30 in the entire range of the adjustment weight built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg