TS-V-1 Dry Cooler
TS-V-1 Dry Cooler
from 67 173 ₽
Dry coolers (autonomous cooling system) are designed to circulate and cool the liquid, which ensures the permissible temperature of the heat-generating object. The product is adapted to work with vacuum drying cabinets of the "SNVS" and "SHSV" type manufactured by TULA-TERM LLC, having a liquid-cooled flange, as well as any equipment using liquid cooling and suitable in characteristics.
Produced in: Tula
Laboratory mill VYUGA-GMO
Laboratory mill VYUGA-GMO
1 supp.
GENERAL CHARACTERISTICS: • Possibility of cleaning and autoclaving of all parts of the grinding set The grinding chamber of the mill and all parts of the grinding set that come into contact with the sample can be easily removed for cleaning and autoclaving, which is an important condition for sample preparation in the determination of GMOs. • Minimal heating of the sample during grinding The special design of the grinding chamber and the use of special knives guarantee minimal heating of the laboratory sample, which eliminates the negative impact on the quality of the extracted DNA. • Grinding with the required quality and homogenization of the sample in one grinding step The ability to select the optimal combination of blade rotation speed, grinding time and automatic rotation of the grinding unit guarantees high-quality, fast grinding and homogenization of samples for various types of samples. • Reproducible grinding results Automation of the grinding process and digital time setting ensure high reproducibility of grinding results. • Easy operation with information display The mill is easy and convenient to operate. Time and grinding mode are set by one button. The information display will show the grinding process parameters. • Grinding of samples with high fat content (up to 55%) The automatic 210° and 90° automatic cycling of the grinding unit, combined with a high grinding speed, minimizes sample heating and oiling of the grinding chamber, which guarantees high-quality, fast grinding and homogenization of samples with a high fat content. 3 grinding chambers are included in the DELIVERY SET of the VYUGA-GMO mill. By separate order it is possible to purchase the required number of grinding chambers.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Aquarius Deionizer
Aquarius Deionizer
from 96 000 ₽
It is intended for obtaining in laboratory conditions from distilled especially pure (deionized) water used for the preparation of solutions, chromatographic samples, refueling of electrolytic hydrogen/oxygen generators and other purposes. Technical specifications The specific conductivity of the resulting water is not more than 0.20* mkSxcm Capacity is at least 6* l/h Metal ion content is not more than: Fe, Pb, Ni, Co 5* mcG/l Zn, Cd, Cu, Mn 1*m cG/l The optical density of ammonia relative to bidistilled water is no more, D - 0.01* Operating time of the replaceable cassette (total volume of purified water) is not less than 700 liters. Volume of refilled distilled water is 1 l Overall dimensions are 180x420x430mm  The weight of the filled device is no more than 9 kg Operating conditions: ambient temperature from +10 ° C to +35 ° C Power supply from single-phase AC 220 V., 50 Hz The power consumption is not more than 20 VA.
Produced in: Moscow
Oxygen concentrator "Provita-580M"
Oxygen concentrator "Provita-580M"
Devices capable of generating oxygen have found the widest application in various fields of medicine. The equipment is also used in training centers, educational institutions and oxygen rooms. Medical oxygen concentrators make it possible to accelerate the recovery of patients suffering from cardiovascular diseases, chronic respiratory diseases, as well as other pathologies that make it difficult to saturate the blood with oxygen. This equipment is a mandatory equipment for anesthesiology and intensive care units. Oxygen concentrators demonstrate high efficiency in restorative treatment. Unlike oxygen sources, which use compressed gas, generators are characterized by high safety and efficiency Capacity: 500-600 l/min 34.8-36.0 m3/h 46.4-47.8 kg/h Oxygen purity: 95 % Oxygen pressure: 4-5 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-212a
Circulation thermostat LT-212a
The LOIP LT-212a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 12 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 190x296/150 Overall dimensions, mm 355x335x370 Weight, kg 10.2
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Power supply C14-100
Power supply C14-100
Operating Mode: Continuous Output stabilized current, A: 1-100 Output voltage, V: 0-14 Power supply: Single-phase mains 220 V; 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 3.8 Overall dimensions (W x H x D), mm: 225 x 85 x 220
INZHEKT
Saratov
Produced in: Saratov
Infrared Laser 980 nm KLM-980-x
Infrared Laser 980 nm KLM-980-x
CDL lasers of the KLM-980 series are optimal sources of continuous radiation for the construction of control and automation systems, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
TWO-CHANNEL LABORATORY INSTALLATION
TWO-CHANNEL LABORATORY INSTALLATION
The bench laboratory unit is designed to test the adsorption properties of silica gels, protective layers and selective hydrogenation catalysts. Ambient temperature from +10 to +35C; The relative humidity of the air is not more than 80% at a temperature of 25C; the power supply is a three- or single-phase AC network with a voltage of 220 V ± 10% with a frequency of 50 Hz. The average service life of the installation is 5 years. TECHNICAL CHARACTERISTICS Operating pressure range, 0.1-10 MPa Reactor operating temperature range, 0C 50÷600 The flow rate range of the pump forming the investigated raw material flow, ml/min 0.1-10 Volume of raw material capacity, l not less than 5 Operating temperature range of the raw material tank, 0C 30÷80 Operating temperature range of high and low pressure separators, 0C 30÷80 Flow range H2, mm/min 50÷3000 The maximum pressure at the outlet of the regulator is H2, MPa 10 Power consumption not more than, kW 6 Overall dimensions, mm 800×1300×2000 The operation mode is cyclic
Produced in: Yoshkar-Ola, Mari El
Vacuum drying cabinet with automatic regulation SNVS-90/5
Vacuum drying cabinet with automatic regulation SNVS-90/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
HL-340-1 POZIS Refrigerator combined laboratory
HL-340-1 POZIS Refrigerator combined laboratory
from 56 603 ₽
Total volume, l. 400 The volume of the refrigerating chamber, l. 270 The volume of the freezer / NTO, l. 130 Number of compressors, pcs. 2 Height, mm 2080 Depth without handle, mm 607 Depth with handle, mm 650 Width, mm 600 Weight, kg., no more than 98 The weight of the refrigerator with metal doors of the upper and lower chambers, kg 91 The maximum rated power of the refrigerating chamber, W 165 The maximum rated power of the freezer, W 140 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Warranty, 1 year Low-temperature separation Rated power consumption of the freezer, W 130 Cold storage Temperature in the refrigerator, °C +2... +15 There is a height adjustment of the shelves Thermal card: yes The nominal power consumption of the refrigerator, W 150 Freezer compartment The temperature in the freezer, °C -25...-10 Efficiency and energy consumption Electricity consumption, kWh/day, no more 1.84 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 91-98 Gross weight of the product, kg 97-104 Volume of packaging, m3 0,876 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 2.14
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan