NGSH V1.3 x 0.65 low-temperature noise generator
NGSH V1.3 x 0.65 low-temperature noise generator
Designed for: use as the primary reference of the spectral power of the noise radio emission SPMSH in the frequency range 140-220 GHz; use as a source of noise signal in the mm wavelength range for use with radio equipment; measuring the noise coefficient of receivers, amplifiers, for tuning and adjusting electronic devices.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region
Optical imaging system for fluorescence and luminescence in LumoTrace® biological samples: LumoTrace® Lite model (bioluminescence)
Optical imaging system for fluorescence and luminescence in LumoTrace® biological samples: LumoTrace® Lite model (bioluminescence)
The lowest cost and most compact version of the LumoTrace® Optical Imaging System manufactured by Abisens LLC for sensitive bioluminescence detection. The compactness and low price of the LumoTrace®Lite imaging system are due to the fact that it allows only bioluminescence to be recorded (older models, in addition to bioluminescence, allow fluorescence to be recorded, and are also modular, which provides them with the opportunity to upgrade). Despite its compactness and relatively low price, this model is equipped with a new highly sensitive digital camera HICMOS manufactured by Abisens LLC, which allows recording ultra-small amounts of phosphor both in laboratory animals in vivo and in vitro experiments. The device is an indispensable tool for conducting preclinical studies on the way to the introduction of advanced drugs, in the implementation of non-invasive monitoring of the development of socially significant diseases, monitoring the effectiveness of immuno- and gene therapy,
Abisens
Sirius
Produced in: Krasnodar region
Nanolab based on NTEGRA PRIMA AFM
Nanolab based on NTEGRA PRIMA AFM
Scanning Probe Microscopy In air and in liquid: AFM (contact + semi-contact + non-contact) / Lateral Force Microscopy/ Phase Mapping/ Force Modulation/ Adhesive Force Mapping/ Lithographs: AFM (Power) Only in air: STM/MSM/ESM/SEM/ Kelvin Probe Method/ Display of Spreading Resistance/ AFAM (on demand)/Lithographs: AFM (Current), STM/.
NT-MDT
Zelenograd
Produced in: Moscow, Zelenograd
Automated VerumSight Fluorescence Microscope (Fluo)
Automated VerumSight Fluorescence Microscope (Fluo)
1 supp.
This laboratory equipment for research purposes allows you to obtain fluorescent images of micro-preparations on slides or in a 96-well tablet in automatic scanning mode. It has high performance and allows you to automate microscopic studies to save researchers time when routinely obtaining a large number of fluorescent images.
Abisens
Sirius
Produced in: Krasnodar region
RNA Vaccine production System
RNA Vaccine production System
1 supp.
It allows the generation of lipid particles for their subsequent use in the creation of RNA vaccines. The Russian equivalent of Nanoassembler systems.
Abisens
Sirius
Produced in: Krasnodar region
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
1 supp.
Technical specifications: Frequency of the generated magnetron radiation, MHz 2450 ±50 Number of simultaneously decomposed samples 1 The maximum volume of the processed sample, cm3 50 Maximum working pressure in the container, atm 9 Power consumption, V*A 600 The average absorbed power (W) in the reactor when heating 30 cm3 of distilled water at 100% output power level of the magnetron in the range of supply voltage from 187 to 242 V 150... 250 Average time to failure, h, not less than 2500 Average service life, years, at least 5 Overall dimensions, mm, no more than 500x450x150 Weight, kg, no more than 22
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
2 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg