Equipment

2226 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 387
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2226 products
Quenching oil tank BZM 14.17.8/09
Quenching oil tank BZM 14.17.8/09
Oil quenching tanks of the tank type are designed for quenching cooling of products heated to the quenching temperature in oil at temperatures up to 90 ° C in stationary conditions. The workspace environment is oil. Oil quenching tank of the tank type BZM 14.17.8/0.9 for quenching cooling of products heated to the quenching temperature in oil in the range from 40oC to 90oC.
Produced in: Tula
Universal voltmeter V7-79
Universal voltmeter V7-79
The voltmeter is capable of operating both independently and as part of automated measuring systems with RS-232 interfaces. Technical specifications Measuring ranges of electrical quantities: - constant electrical voltage from 10 MV to 1000 V - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) from 1 mV to 750 V - RF RF AC voltage in the frequency range from 10 kHz to 1500 MHz (RF) from 10 mV to 1000 V - DC electric current from 0.1 µA to 20 A - SCZ of alternating electric current in the frequency range from 10 Hz to 5 kHz from 10 µA to 20 A - electrical resistance from 10 mOhm to 1 GOm - frequency of the measured AC voltage from 10 Hz to 1 MHz Measurement errors of electrical quantities: - constant electrical voltage ± (0.0028 - 20)% - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) ± (0.09 - 15)% - RF RF AC voltage in the frequency range from 10 kHz to 1500 MHz (RF) ± (1.6 - 66)% - DC current ± (0.012 - 20)% - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz ± (0.11 - 2.35)% - electrical resistance ± (0.007 - 5.5) % - frequency of the measured alternating electric voltage ± (0.1 -10.1) % General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 20 VA Overall dimensions, mm 291x110x308 Weight, not more than 4.5 kg
Produced in: Moscow
POZIS PHARMA PH 31 Tablet press
POZIS PHARMA PH 31 Tablet press
Productivity, thousand tab./hour 160 Number of stations 31 Max. pressing force, tn 10 Number of threads 2 Diameter of tablets, mm 6-25,4 Height of tablets, mm 1.5-9 Matrix filling depth, mm 18 Rotor material steel 40x13 Filling hopper capacity, l 20(30) Stepless rotor speed change The change in the speed of rotation of the feeder is independent Supply voltage 380V, 50Hz Power consumption, kW/hour 5.78 Weight, kg 2400 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
LB31 Laboratory bath
LB31 Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Three workstations with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 5 liters and a depth of 60 mm. The volume of the bath is 5 liters Overall dimensions 355x310x285 mm The open part of the bath is 295x235 mm Bath depth 60 mm Weight 9 kg Power consumption 2.5 kW
Produced in: Tomsk
Vacuum drying cabinet with manual control SNVS-50/3.5
Vacuum drying cabinet with manual control SNVS-50/3.5
from 340 671 ₽
The SNVS-50/3.5 vacuum drying cabinet with a volume of 50 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 350 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula
Horizontal Drying Vacuum Chamber SNVS-512/0.8-I2-2B
Horizontal Drying Vacuum Chamber SNVS-512/0.8-I2-2B
Horizontal drying vacuum chamber SNVS-512/0.8-I2-2B is designed for rapid vacuum drying of heat-sensitive elements with hidden cavities and containing a large volume of moisture. The use of a plate heat exchanger allows you to condense up to 10 liters of liquid (in the standard version) and prevent it from entering the pump. The presence of a fan significantly reduces the initial heating time of the part. The shelves are fixed on roller guides and can be freely extended. The shelf is designed for a distributed load of up to 250 kg.
Produced in: Tula
2VVN1-12M(N) Water ring vacuum pump
2VVN1-12M(N) Water ring vacuum pump
The use of a 2VVN1-12M(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-12M(N) pump. The 2VVN1-12M(N) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
Metal tripod Sh-10/30, pack.12 pcs, MiniMedProm
Metal tripod Sh-10/30, pack.12 pcs, MiniMedProm
from 380 ₽
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storing test tubes.
MiniMed
Suponevo
Produced in: Bryansk region
Thermostat for determining viscosity LT-910
Thermostat for determining viscosity LT-910
Design features: Microprocessor-based PID controller; Multifunctional control knob; Efficient mixing system; Self-diagnosis system; Simple correction of internal temperature sensor readings; Two-point calibration; Built-in cooling coil; Technical specifications: Number of seats for viscometers 3 Temperature range - without external cooling, °C - with tap water cooling, °C - with cryostat cooling, °C (Current+10)...+150 (Tvods+5)...+150 0...+150 The error of setting the set temperature, ° C ± 0.02 Temperature maintenance error, ° C ± 0.01 Power consumption, W 1500 Overall dimensions, mm 380x235x560 Working depth, mm 300 Volume of working fluid, l 14 Weight of the device without liquid, kg 16
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace MIMP-75P (floor version)
Muffle furnace MIMP-75P (floor version)
The furnace can be used as a universal laboratory muffle furnace in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications The furnace operates at ambient temperatures from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. The designation of the furnace when ordering: muffle furnace MIMP-75P, where 75 indicates the volume of the furnace working chamber in liters. Power consumption – 15000 watts Dimensions of the working chamber WxDxH- 350x630x320 mm Dimensions WxDxH- 970*x1150x1450 mm (* - with control unit) Weight – 224 kg
MIUS
Tula
Produced in: Tula
Exposure device UER-03 (TU 26.51.70-003-63790925-2021 )
Exposure device UER-03 (TU 26.51.70-003-63790925-2021 )
1 supp.
The principle of operation of the device UER-03: The principle of operation of the device is based on the creation of equal conditions for all exposed samples during biotesting. It is achieved by rotating the cassette with the test culture samples of crustaceans installed in it around the central axis. Since the sample cassette is oriented obliquely, when it rotates, there is an active gas exchange between the surrounding air and water samples. As the result, test organisms in test tubes are provided with sufficient oxygen concentration in the medium during the entire exposure period. The rotation speed of the cassette is chosen so as not to have a stress effect on the crustaceans. The device operates in continuous mode and does not require additional intervention in the process of exposing the crustacean culture. The required conditions for temperature and light irradiation can be provided only when the device is installed in the climatostat. Used in techniques: - Methodology for determining the toxicity of water extracts from soils, sewage sludge and waste, drinking, sewage and natural water by the mortality of the test object (Daphnia magna Straus). MON F 14.1:2:4.12-06 / 16.1:2.3.3.9-06 FR.1.31.2009.06641. - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles, according to the mortality of the test organism Daphnia magna Straus. FR.1.39.2010.09102 And it can also be used in other suitable techniques.
Evropolitest
Ivanteevka
Produced in: Moscow region
Cable searcher Athlete AG-319M (frost-resistant)
Cable searcher Athlete AG-319M (frost-resistant)
from 338 100 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). The kit includes a receiver in the form of a monoblock with a frost-resistant LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line and the most powerful multi-frequency generator in the TECHNO-AC line, with a range of up to 10 km.
Produced in: Kolomna, Moscow region