NTEGRA NANO IR
NTEGRA NANO IR
NT-MDT Spectrum Instruments is an INTEGRA Nano IR–scattering scanning near‑field optical microscope (s-NSOM) designed for the infrared spectral range. The AFM probe is located in the focus of an optical system that directs the IR laser radiation to the sample and collects the optical response. The collected radiation is sent to the Michelson interferometer for optical analysis. The far-field component of the collected signal is suppressed by synchronous detection. The INTEGRA Nano IR system allows detecting the amplitude and phase of the near-field signal. The spatial resolution of the resulting reflection and absorption contrasts is approximately 10 nm and is determined only by the size of the tip of the probe.
Produced in: Moscow, Zelenograd
Blue DPSS Laser 465 nm KLM-465-x
Blue DPSS Laser 465 nm KLM-465-x
DPSS lasers of the KLM-465/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 15 W Radiation wavelength: 465 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN IS, IS-T
Sulfur Analyzer SPECTROSCAN IS, IS-T
The IS-T and IS X-ray absorption flow SPECTROSCAN analyzers for sulfur in oil are designed to determine the mass fraction of sulfur in the flow of oil/petroleum products in the range from 0.02% to 6.00% (IS-T) or 0.04% to 6.0% (IS). Analyzers can be used for technological control during transportation and storage of oil, as well as during mixing (compounding) operations. The design of the analyzers allows them to be placed both independently and as part of a unit for measuring oil quality indicators (BIC) or a system for measuring the quantity and quality of oil (CIC). They are available in explosion-proof version. The analyzers have the function of automatically accounting for the influence of the density of the analyzed medium, as well as the content of water and chloride salts in it on the result of determining the mass fraction of sulfur. Structurally, the analyzers are a complete product of high factory readiness, having a block-modular design and including all the necessary functional devices to ensure efficient and safe operation.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Industrial Drying Cabinet SNOL (SHS) 200/3-I2 V
Industrial Drying Cabinet SNOL (SHS) 200/3-I2 V
from 453 694 ₽
Industrial drying cabinet SNOL (SHS) 200/3-I2 V is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 350 (optionally up to 500) ° C with forced air convection in stationary conditions.
Produced in: Tula
Modular installation of liquid cooling VCHV-5
Modular installation of liquid cooling VCHV-5
from 213 120 ₽
Designation VCHV-5 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 5 Required pump capacity, m3/h 1,2 Pressure loss in the heat exchanger, kRa 30
Produced in: Tula
Universal calibrator H4-301/1
Universal calibrator H4-301/1
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (UK) 200 MV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range Uk 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, sv. 20 to 40 kHz 0.2 + 0.1 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 2; 20 V 0.15 + 0.02 Basic error, ± (% of U + % of Uk): from 20 Hz to 20 kHz 0.15 + 0.02 Uk 200 V; 600 V: 0.2 + 0.05 from 40 Hz to 1 kHz 0.2 + 0.05 DC power reproduction range: from 1 Ma to 200 mA, sub-bands (Ic) 200 Ma; 2; 20; 200 mA Ic 200 Ma 0.1 + 0.02 Basic error, ± (% of I + % of Ic): Ic 2; 20; 200mA 0.1 + 0.01 Power reproduction range AC: from 10 Ma to 200 mA, sub-ranges (Ic) 200 Ma; 2; 20; 200 mA 0.15 + 0.05 Frequency range from 20 Hz to 1 k Hz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 to +50 C Dimensions; weight 428×327×235× mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Phytotron (Climate Chamber) I-250
Phytotron (Climate Chamber) I-250
1 supp.
Functional features Working volume 250l. Maintenance of a wide temperature range in the working area (from -5 ° C to 50 ° C). LED lighting with variable spectrum and intensity. Multi-zone lighting distributed over the working volume. Four removable shelves. Execution of the working chamber: stainless steel. A two-door system for the possibility of surveillance. Multi-zone temperature monitoring. Control of the moisture content in the soil. Color TFT display.
Prointekh
Pushchino
Produced in: Moscow region, Pushchino
Liquid low-temperature thermostat CRYO-MT-08
Liquid low-temperature thermostat CRYO-MT-08
Operating temperature range 0...+100 °C. Bath volume 18 l Overall dimensions 450x700x640 mm The open part of the bath is 165x165 mm Bath depth 300 mm Weight 47 kg Power consumption 3.5 kW
Produced in: Tomsk
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 10 mm Hg SHSV-14/2,5
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 10 mm Hg SHSV-14/2,5
The electric vacuum drying cabinet SHSV-11/2.5 is designed for drying and heating various materials in air and in vacuum at a maximum temperature of 250 ° C. In the model with the index "C", the door is made of heat- resistant glass. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C Operating temperature- 250 ⁰C Power consumption - 1000 watts Dimensions of the working chamber - 200x350x200 mm Dimensions WxDxH- 450x930x470 mm Weight - 20 kg
MIUS
Tula
Produced in: Tula
Vacuum Drying Cabinet
Vacuum Drying Cabinet
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula