Heating mantleLH-225 (50-250 ml)
Heating mantleLH-225 (50-250 ml)
The volume of the heated flask, ml 50-250 Maximum heating temperature, °C 600 Dimensions, mm 170x230x160 Power, W 550 Weight, kg 3
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory electric furnace CHO-34
Laboratory electric furnace CHO-34
from 276 396 ₽
Designation SNO-34 Volume, l 34 Material of the working chamber ceramics Heating 4 sides Power consumption, W, max 10000 Minimum operating temperature, 0C 100
Produced in: Tula
Electric resistance furnace tubular laboratory SUOL-0,9.7/15
Electric resistance furnace tubular laboratory SUOL-0,9.7/15
Electric resistance furnace tubular laboratory SUOL-0,9.7/15 is designed for heat treatment of various materials and other work at a temperature of 1500oC.
Produced in: Tula
Laboratory shaft furnace SSHOL-8/11
Laboratory shaft furnace SSHOL-8/11
from 197 354 ₽
Designation SSHOL-8/11 Supply voltage, 220 ± 10% Network frequency, Hz 50 Power consumption, W, max 4000
Produced in: Tula
Distillate receiving and distribution station
Distillate receiving and distribution station
Depending on the technical specification, the equipment includes: a distiller of the ADE or DE series, a distillate storage collection with a volume of 60 to 500 liters. a pumping group, and an automation system. A different number of consumers can be connected to the station. The installation of receiving, storing and distributing distillate to 2, 3, 5 or more supply points is most in demand in institutions and enterprises with a large consumption of distilled water, for example, in dental clinics, etc. The distillers included in the unit allow you to get from 40 to 280 liters per hour of 3 types of water without the use of expensive filters, resins, and special membranes. The quality of the produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current: alternating three-phase Frequency: 50 Hz Voltage: 380V (±10%)
Livam
Belgorod
Produced in: Belgorod
LI-1000 Integrated Vacuum Trap
LI-1000 Integrated Vacuum Trap
The LI-1000 integrated flanged trap is installed inside the diffusion pump instead of the standard oil reflector, without increasing the overall dimensions of the diffusion pump. The LI-1000 trap performs the function of an oil reflector, is installed instead of a standard oil reflector in pumps, has an additional number of cooled screens for capturing oil return flow vapors (more than that of the MU trap), covers the entire area of the input high-vacuum flange.
Produced in: Kazan
Muffle furnace LF-5/13-V2
Muffle furnace LF-5/13-V2
1 supp.
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x190 mm Overall dimensions, WxHxD, not more than mm 505x955x565 Rated supply voltage, 220 V Rated power, W 2800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Water bath WB-6
Water bath WB-6
Temperature setting range, oC +35…+95 Temperature error, oC ±1.0 is protected from excess temperature RAINBOW TSR-150S F-C Hydraulic thermostat Supply voltage, V 230+-10% Current consumption 6.5A Power consumption, 1500 W Overall dimensions L x W x H, mm 450 x 300 x 190 Overall dimensions of the bath L x W x H, mm 360 x 300 x 140 Total / engine capacity, 14.9/11.2 l
Produced in: Belarus, Minsk
Blue DPSS Laser 447 nm KLM-447-x
Blue DPSS Laser 447 nm KLM-447-x
DPSS lasers of the KLM-447/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 120W Radiation wavelength: 447 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
NVD-600 Two-rotor Vacuum Pump
NVD-600 Two-rotor Vacuum Pump
The NVD-600 two-rotor vacuum pump is not designed for pumping air, vapors and vapor-gas mixtures from one volume to another. The NVD-600 two-rotor pump can only work in conjunction with a pre-vacuum pump, and is designed for pumping in the pressure range from 1.3·102Pa (1 mm Hg) to the maximum residual pressure. The speed of action of the forvacuum pump for NVD-600 is not less than 60 m3/h. The temperature of the pumped media at the inlet to the pump NVD-600 should not exceed the maximum operating values of the ambient temperature according to GOST standard 15150-69, at which the pump is operated. At an operating pressure of more than 5 mm Hg for the HVD-600, the bypass valve is in the open position. The pumped gas is partially bypassed through channels in the pump housing from the outlet to the inlet of the pump NVD-600, which ensures the operability of the pre-vacuum pump and prevents overheating of the pump NVD-600. The NVD-600 double-rotor vacuum pump can operate continuously at an inlet pressure of no more than 133 Pa (1 mm Hg) or pumping out one or more sealed vessels with a total volume of 7.5 m3 for the pump from atmospheric to the maximum residual pressure for 8 hours.
Produced in: Kazan
Vacuum drying cabinet with automatic adjustment SNVS-25/5
Vacuum drying cabinet with automatic adjustment SNVS-25/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula