Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
Contact thermometer TK-5.08 with the function of measuring relative humidity (explosion-proof)
Contact thermometer TK-5.08 with the function of measuring relative humidity (explosion-proof)
from 43 200 ₽
A unique, reliable device with a huge number of replaceable probes. The contact thermometer TK-5.08 is designed to solve problems of any complexity with the highest accuracy in the field of measuring the temperature of flammable liquids, bulk substances, air, explosive gas mixtures, solid surfaces and relative humidity of the air-gas environment at oil and gas and chemical industry enterprises. Shock-resistant and frost-resistant design allows you to operate the device in harsh climatic conditions.
Produced in: Moscow
AD-42IP Acoustic Flaw Detector
AD-42IP Acoustic Flaw Detector
from 383 500 ₽
It is especially effective for use in products made of composite materials (including with honeycomb filler). Distinctive features: The AD-42 IP is a compact acoustic system sensitive to changes in mechanical impedance caused by product defects. The indication of the device indicates that there are voids, non-adhesives, delaminations or changes in the structure of composite materials (including with honeycomb filler and laminated plastics) under the sensor. The device is used to monitor various materials and their combinations. The energy consumption of the unit is low because the converter is switched on when the sensor is placed on the monitored product. Being light enough, the device allows you to perform monitoring in hard-to-reach places or in confined spaces. The results of the control can be stored in the built-in non-volatile memory and transferred to a PC. Converters Options: - 3 types of converters for various tasks Emitters: - 1 or 2 on each converter Switching-on: - The converters are switched on when they are placed on a controlled object. Technical characteristics: Weight, kg: 0.73 Dimensions, mm: 210x150x70 Power supply: 4 AA batteries Work without recharging the battery, h: 8 Battery discharge visual indication The defect alarm is visual on the converter and audible on the instrument panel (or) in headphones.
Produced in: Moscow
Exhaust cabinet with integrated glass-ceramic hob LAB-PRO SHVVP 120.84.230 VI
Exhaust cabinet with integrated glass-ceramic hob LAB-PRO SHVVP 120.84.230 VI
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. steel (AISI 316) rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather inner capsule made of polypropylene lined with ceramic plates of the rear and side panels to a height of 380mm 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – polypropylene on the upper panel: LED lamp dust- and moisture-proof 2x10 W (IP65) is separated from the workspace by tempered glass with a thickness of 4mm flange d=250mm (distance from the back panel to the center of the flange – 170mm) switching box with automatic emergency power off 16A 3 exhaust levels easily removable exhaust canopies the glass ceramic heating platform is located in the center of the countertop size 640*500mm (working area 580*430mm, 2 independent heating zones) power up to 5.7kW heating up to 400 ° C counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - aluminum profile painted with powder paint (RAL 5023) with the texture of shagreen leather adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Multifunctional UKRV-2 air flowmeter
Multifunctional UKRV-2 air flowmeter
Purpose: measurement of the volume of air pumped through the analytical filter; measurement of volumetric air flow through an analytical filter. Features: output of information to the LCD indicator; automatic and manual control of an external actuator (valve, crane); obtaining information about the analytical filter used using a barcode reader; transmission of data on the state of the device, the measured volume flow and the pumped volume of air to communication channels; providing access to information via the RS-485 interface; work both independently and as part of radiation monitoring systems
Doza
Zelenograd
Produced in: Moscow
Hydraulic rack TSK-600
Hydraulic rack TSK-600
The hydraulic rack TSK-600 is an automated auxiliary equipment for creating pressure. It is used for checking pressure gauges, pressure transducers, pressure switches and other pressure systems used at the enterprise. The presence of a precision pressure regulator and a built-in amplifier allows a user to create the necessary pressure with a discreteness of 1 kPa easily and accurately. To ensure the operation of the rack in the entire range, it is necessary to have a reference pressure of 0.85 MPa which comes from an external pressure source: a compressor, a KIP air network, a gas cylinder. For operation within the range from 0 to 2.5 MPa, the supply of reference pressure is not required. The TSK-600 hydraulic rack can be manufactured in a version with 2, 3, 4, or 5 stainless steel output ports for setting the reference and verifiable SI. Each output port is equipped with a quick-release adapter with an internal thread M20x1.5 or G1/2, due to which the installation of verifiable SI does not require the use of wrenches. To protect the hydraulic system of the rack from contamination, a replaceable filter of 100 microns is installed in each output port, and the discharge of the working fluid is carried out through a separate discharge line to an external tank. Additionally, the rack can be equipped with measuring channels for checking pressure transmitters and with an alarm unit for ECM. TSK-600 is a unique solution for a metrological laboratory, which makes it possible to facilitate the work of personnel as much as possible and optimize the process of pressure SI verification. Features: • Easy to operate and maintain. • Setting and adjusting the pressure with the movement of one finger. • Multiple output ports for more efficient verification process. • The protection against contamination.
Tekknow
Saint Petersburg
FUME HOOD FOR MUFFLE FURNACES
FUME HOOD FOR MUFFLE FURNACES
from 92 910 ₽
The SHVM fume hood is designed for the installation of muffle furnaces and drying cabinets. It can be equipped with cabinets made of steel. 1. LC-900 SHVM Width - 960 GRANTEC - 72 550 ₽ 2. LC-900 SHVM with protective screen Width - 960 GRANTEC - 88 910 ₽ 3. LC-1200 SHVM Width - 1260 GRANTEC - 83 860 ₽ 4. LC-1200 SHVM with protective screen Width - 1260 GRANTEC - 100 390 ₽ 5. LC-1500 SHVM Width - 1560 GRANTEC - 95 270 ₽ 6. LC-1500 SHVM with protective screen Width - 1560 GRANTEC - 107 690 ₽
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Universal frequency meter Ch3-86A
Universal frequency meter Ch3-86A
The frequency meter is capable of operating both independently and as part of automated measuring systems with an interface such as USB, RS-232 or IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal and video pulse signals (input A) 0.005 Hz - 100 MHz Frequency of sinusoidal and video pulse signals (input to) 0.01 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (0.6 - 17.85) GHz Pulse duration 10 ns - 10000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from 0 to 10000 s The frequency ratio of the two signals is up to 109 The average value of the carrier frequency of the pulse-modulated (IM) signal (input D) (0.6 - 17.85) GHz Frequency measurement resolution 2x10-10 s/Rng Phase difference of two synchronous sinusoidal signals from minus 180° to 180° Measurement error of the phase difference of two synchronous sinusoidal signals ± 0.36° (from 1 kHz to 1 MHz)±3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 30 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •inputs C, D (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz; 220 V, 400 Hz Power consumption, no more than 50 VA Overall dimensions, mm 229x136x435.5 Weight, not more than 7.5 kg
Produced in: Moscow
Universal frequency meter Ch3-89
Universal frequency meter Ch3-89
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
Produced in: Moscow