The aspirator refers to universal, electric, single-channel, portable devices with set volume flow values, with direct measurement of the sampled volume of air samples in accordance with GOST R 51945-2002.
The individual aspirator BREEZE-2 is designed to select and measure the volume of maximum one-time, average shift and average daily (in the employee's breathing zone) samples of atmospheric air of populated areas, air of the working area, air of residential and public premises, medical institutions for the content of harmful substances.
The PA-1 single-channel portable aspirator is based on the PC-1 portable compressor. It provides air aspiration with a flow rate from 0.1 to 0.8 l/min. The aspirator is powered by an integral battery.
General monitoring of contamination of various objects with radioactive substances in the counting rate mode, with the possibility of separate measurement of the alpha particle flux density and beta particle flux density, as well as the gamma radiation dose rate
A wide range of measurements
The possibility of using an extension rod
High sensitivity
Sound, light and visual alarm of exceeding the set threshold levels
The possibility of using both stationary and wearable versions
A wide range of measurements
Technical specifications:
Maximum load (torque): 30 N·m
Maximum twisting angle: 50000°
The discreteness of the twisting angle: 0.01°
Twisting angle error: ±0.1°
Torque discreteness: 0.001 N·m
Relative error of torque measurement: no more than 1% in the measurement range from 0.6 to 30 Nm
Torque measurement error: no more than 0.01 N·m in the measurement range from 0 to 0.6 N · m
Maximum rotation speed: 10 rpm
Weight: 150 kg
Overall dimensions (length x width x height): 1000 x 500 x 500 mm
Diameter of the universal testing device: 80 mm
Maximum spring length: 300 mm or more
Application range: 1.0 – 20.0 m/s;
Accuracy characteristics: PG±(0.3+0.05V)m/s;
Service life of at least 6 years;
Overall dimensions 170 x 70 x 70 mm;
Weight 0.25 kg;
Application conditions from -45°C to +50°C;
Minor variations in the design of the device are possible.
Designed for:
measurements (along with the primary measuring transducers of PIP) of vibroacoustic characteristics according to specified algorithms during complex monitoring of buildings, structures and mechanisms.
The error is ± 0.05 °C in the range of -50...+300 °C.
The minimum immersion depth of the sensor is 75 mm
Overall dimensions of the electronic unit 80x75x100 mm
Weight 0.25 kg
Purpose:
measurement of the individual dose equivalent of Hp(10) photon radiation;
measurement of the individual dose equivalent of Hp(10) neutron radiation;
measurement of the individual dose equivalent in the skin Hp(0.07) and the lens of the eye Hp(3) of photon and beta radiation;
measurement of ambient dose equivalent H*(10) of photon radiation.