Metrology

525 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 194
    Names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 31
    Made in
    Loading...
  • 55
    Additional
    Loading...
View:
525 products
Measuring antenna P6-61
Measuring antenna P6-61
Technical specifications: Frequency range (26.0 - 300) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 145x75x1720 mm Weight 0.7 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-23M
Measuring antenna P6-23M
Technical specifications: Frequency range (0.85 - 17.44 GHz) Standing Wave Coefficient (SWR) < 1.7 Effective area at least in the frequency range - from 0.85 to 15 GHz > 150 cm2 - from 15 to 17.44 GHz > 110 cm2 The margin of error of the effective area in the frequency range, no more - from 0.85 to 8.5 GHz ± 20% - from 8.5 to 17.44 GHz ± 15% Orthogonal polarization signal level -25 dB The level of the side lobes, no more than -10 dB Ambient temperature -50°C - 50°C Gabbar dimensions (HxWxD) 887x351x265 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Navigation Systems Receiver module
Navigation Systems Receiver module
On the two high-frequency outputs of the receiver board, the signals of the second mark of the navigation receiver and the RF, which are available for the customer`s use, are generated. When receiving signals from satellites of the GLONASS and GPS radio navigation systems, the board ensures the operation of the RF in the frequency binding mode according to the signals of the second timestamp (the so-called “disciplined” rubidium frequency standard mode) with an error of the actual value of the RF frequency for no more than ± 5.10-12
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Frequency Synthesizer Module
Frequency Synthesizer Module
Designed in the form of a module, standard for RUKNAR CJSC, it can be installed in any modular device of our production, elevating its functionality to a fundamentally new level. The synthesizer module consists of three independent devices: a frequency synthesizer, a standard signal generator and a time scale generator. The module has external control via USB 2.0 interface from a personal or tablet computer.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Smart air probe L=500 mm SSV.500P with built-in flash memory
Smart air probe L=500 mm SSV.500P with built-in flash memory
from 13 248 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. The smart air probe L=500 mm SSV.500P with built-in flash memory is designed to measure the temperature of various media by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.500P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.500P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Second Mark Shaper Module
Second Mark Shaper Module
Pulse duration: ......10-15 microseconds The duration of the leading edge of the pulse:......no more than 20 ns Pulse amplitude: ...... at least 3V at a load of 50 ohms
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
AC voltage source B2-7
AC voltage source B2-7
The AC voltage source B2-7 is intended to provide devices and equipment with a stabilized AC voltage during the development, production, operation and repair of electronic devices. Main properties: Provides protection against overload and short circuits at the output. Has a light indication: - overload and short circuit protection tripping; - incorrect connection of the power supply line to B2-7. Technical specifications The nominal value of the output voltage (SKZ) 220 V The nominal value of the input and output voltage frequency is 50 Hz Output electrical power, not less than 1000 VA The main error in setting the output voltage is ± 2.2 V Additional error in setting the output voltage caused by a deviation of the input voltage by ± 10% from the nominal value of 220 V ± 1.0 V Additional error in setting the output voltage caused by a change in the load current from the maximum value to zero ± 2.0 V Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 2.0 V Operating temperature range from -10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 1200 VA Overall dimensions, mm 240x128x349 Weight, not more than 6.5 kg
Produced in: Moscow
Electronic explosion-proof thermometer ExT-01/2-6
Electronic explosion-proof thermometer ExT-01/2-6
The thermometer sensor ExT-01/2-6 is made in the form of a fully submersible probe with a cable length of 6 meters. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
Metolab 202 Rockwell Hardness Tester
Metolab 202 Rockwell Hardness Tester
METOLAB 202 is a stationary automatic hardness tester designed to measure the hardness parameters of various materials and products on the A, B, C Rockwell scales and the HR15N, HR30N, HR30T, HR45N Super-Rockwell scales. The device has a large and bright display, which displays all the necessary service information, and is also equipped with a built-in mini-printer, so that it is possible to quickly print out the information received on paper. Other features of the METOLAB 202 hardness tester include a fully Russified menu, a wide range of measured values, as well as full compliance of measurements with current standards, including BS.EN 10109 and ISO716. The stationary METOLAB 202 hardness tester allows you to apply a loading force in 15, 30, 45, 60, 100, 150 kgf and preload 3 kgf, 10 kgf. The device is entered in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 65128-16 and comes with a certificate of primary verification (on request). Regulatory and technical documents establishing requirements for the METOLAB 202 hardness tester: GOST 8.064-94 GSI. State verification scheme for hardness measuring instruments on the Rockwell and Super-Rockwell scales; GOST 9013-59 Metals and alloys. Rockwell hardness measurement method. Scales A, B, C; GOST 22975-78 Metals and alloys. Rockwell hardness measurement method at low loads (Super-Rockwell); GOST 23677-79 Hardness testers for metals. General technical requirements. Distinctive features of the stationary METOLAB 202 hardness tester: All measurements take place in fully automatic mode; The ability to set the upper and lower measurement limits, audible alarm when the results exceed the set values; Opportunity to process statistical data – calculation of minimum/average/maximum values, as well as other functions; Conversion of the obtained results into the Vickers, Brinell and Super-Rockwell scales; Correction for curvature of cylindrical and spherical parts; Simple and intuitive interface in Russian. Basic package of delivery: Stationary Metolab 202 Rockwell hardness tester; Indenter with a ball (1.5875 mm) - 1 pc.; Conical diamond indenter (120°) - 1 pc.; Flat table SP1 (60 mm); V-shaped prismatic table SRP1 (40 mm); Rockwell and Super-Rockwell Hardness Measures; User Manual.
Metolab
Moscow
Produced in: Moscow
Universal Metolab 703 Hardness Tester
Universal Metolab 703 Hardness Tester
Stationary universal METOLAB 703 hardness tester is a multifunctional device designed to measure the hardness of materials and products on the Rockwell, Brinell and Vickers scales. The device is a modification of the METOLAB 701 and METOLAB 702 meters. Among the features of the METOLAB 703 hardness tester, the following should be mentioned: a special force sensor for monitoring the applied load; a large and bright color display; software with many functions (including statistical ones – calculation of minimum/average/maximum values, conversion of the results into various scales, automatic switching on of the load, storing data in memory); U-disk for saving and transferring data; creating and editing spreadsheets in Excel format; digital calibration and much more. Distinctive features of the stationary universal multifunctional METOLAB 703 hardness tester: A large number of scales for measurements; Rockwell scales: A, B, C, D, E, F, G, H, K, L, M, P, R, S, V; Brinell scales: HBW1/5, HBW2.5/62.5, HBW1/10, HBW2.5/15.625, HBW1/30, HBW2.5/31.25, HBW2.5/62.5, HBW10/100, HBW5/125, HBW2.5/187.5; Vickers scales: HV5, HV10, HV20, HV30, HV50, HV100, HV12; Multifunctional software in the basic package; Fully Russian-language device menu, simple and intuitive interface; Wide range of measured values: 8 – 650 HB; 20 – 93HRA; 20 – 100 HRB; 20 – 70 HRC; 8 – 2900 H; Load application monitoring using a force sensor; Large and bright color display; Creating and editing spreadsheets in Excel format; U-disk for saving data; Digital calibration of the device; Built-in measuring microscope with backlight. Basic delivery package: Stationary universal METOLAB 703 hardness tester; Conical diamond Rockwell indenter (120° angle) - 1 pc.; Vickers diamond indenter (136° angle) - 1 pc.; Indenter with 1.5875 mm ball - 1 pc.; Indenter with 2.5 mm ball - 1 pc.; Indenter with 5.0 mm ball - 1 pc.; Indenter with 10.0 mm ball - 1 pc.; Large flat table 150 mm - 1 pc.; Medium flat table 60 mm - 1 pc.; V-shaped table 40 mm - 1 pc.; Hardness measures - 1 set; 15x microscope - 1 pc.; 2.5x lens - 1 pc.; 5.0x lens - 1 pc.; User Manual.
Metolab
Moscow
Produced in: Moscow
Pulse DC power supply B5-71/5-PRO
Pulse DC power supply B5-71/5-PRO
1 supp.
Regulated switching power supplies with highly stable output characteristics Digital display of set and actual value, voltage and current (4 digits, LED) Electronic load switching on/off Protection against overload, short circuit, overheating and reverse polarity Low ripple output voltage less than 2mV Low ripple output current less than 5mA Minimum discreteness of setting output voltage and current 0.007/0.005 Operating modes: stabilization U and I, dynamic load RS-232 interface
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
The PKN-2 device
The PKN-2 device
The PKN-2 device is designed to determine the swelling coefficient of clays. Device indicators: Indicator division price, mm — ( 0.01 ) Working stroke of the indicator rod, mm — ( 11.5 ) Overall dimensions, mm — ( 60x85x415 ) Weight, kg — ( 0,7 )
Produced in: Krasnodar