Rubidium frequency and time standards H1-1011
Rubidium frequency and time standards H1-1011
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The composition of the standards H1-1011 and H1-1011/2 includes: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
VLE-1023CI Comparator Scales
VLE-1023CI Comparator Scales
1 supp.
Technical characteristics: NIP, G1020 Discreteness, g0,001 Self-calibration The size of the scale bowl / platform, mm108x105 The smallest weighing limit, g0,1 The price of the verification scale division, mg10 The limits of permissible error during initial verification, mgot 0.1g to 500 g incl. ±5; sv. 500g to 1020g incl. ±10 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 4 in the entire range The weight adjustment is built-in The setting time, s, no more than ~ 1.5 7 years warranty
NPK LUCH
Balashikha
Produced in: Balashikha, Moscow region
M-95-CM Signal Digital Anemometer Sensor
M-95-CM Signal Digital Anemometer Sensor
from 26 022 ₽
Application range: 1.8 ... 55.0 m/s Alarm threshold setting range: wind speed from 12 to 40 m/s The range of setting alarm thresholds in time is from 2 to 5 seconds. Accuracy characteristics: PG±(0.5+0.05V) m/s The average service life is at least 8 years. Application conditions: wind speed sensor from -60C to +50C
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
Measuring recorder IS-203.2.0
Measuring recorder IS-203.2.0
from 28 152 ₽
The meter-recorder IS-203.2 is a microprocessor-based meter designed to measure temperature. Equipped with a non-volatile storage device and a real-time clock. The device has two measuring channels. The measurement results are stored in the non-volatile memory with a volume of 15,000 measurements per channel. The operating conditions of the meter IS-203.2.0 Ambient temperature, ° C: -20...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7. Scope of application of the meter IS-203.2.0 Control of technological processes in various industries, including: utilities, construction, food and pharmaceutical industries, agriculture, etc. Warehouses (grocery, industrial, pharmaceutical, etc.). Transportation (grocery, industrial, pharmaceutical, etc.). Functionality of the meter IS- 203.2.0 Temperature measurement by external sensors. Saving the measurement results in the device memory. Indication of the results of current measurements, time, channels included, interval between measurements, free memory of the device, battery capacity, serial number of the device, time of the next measurement. Operational start and stop of the measurement process. Data transfer to a PC via a COM port or USB.
Produced in: Kolomna, Moscow region
Microphone condenser capsule MK-265
Microphone condenser capsule MK-265
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Individual aspirator BREEZE-2
Individual aspirator BREEZE-2
from 25 500 ₽
The individual aspirator BREEZE-2 is designed to select and measure the volume of maximum one-time, average shift and average daily (in the employee's breathing zone) samples of atmospheric air of populated areas, air of the working area, air of residential and public premises, medical institutions for the content of harmful substances.
Produced in: Moscow
 Wall-mounted Smart Atmospheric Pressure and Temperature Probe
Wall-mounted Smart Atmospheric Pressure and Temperature Probe
from 10 680 ₽
The smart probe of atmospheric pressure and temperature is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, atmospheric pressure by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZDAN smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
HUMAN RADIATION SPECTROMETERS SKG‑AT1322, SKG‑AT1322/1
HUMAN RADIATION SPECTROMETERS SKG‑AT1322, SKG‑AT1322/1
Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
Universal frequency meter Ch3-97
Universal frequency meter Ch3-97
The device successfully combines simplicity of design, modern design, convenience, clarity of control and obtaining information about the measured physical quantity. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (0.3 – 37.5) GHz Carrier frequency of a continuous radio pulse sequence (IM) signal (input C) Fn = (0.3-37.5) GHz, from 0.3 microseconds to 1ms, Fsl from 100 Hz to 1 MHz, from 2 to 103 Frequency ratio (inputs A, B) from 1 to 3x109 Pulse duration 5 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Phase difference of two synchronous sinusoidal signals from minus 180° to 180° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 2.3 ° at a signal amplitude of 1 V Setting range of trigger levels (inputs A, B) from - 2.0 to 2.0 V The error of setting the trigger levels (inputs A, B) ± 0.01 V Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 10.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) 0.1 - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 24 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 306x129.5x430.6 Weight, not more than 8.5 kg
Produced in: Moscow