Laboratory electronic thermometer LT-300-T
Laboratory electronic thermometer LT-300-T
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 °C (Class C according to ASTM E2877). The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 75x80x35 mm Weight 0.2 kg
Produced in: Tomsk
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
Measurements in wide ranges of capacities doses and energies Measurement of dose rate and duration of exposure during short-term radiation from 0.03 s Measurement of the average dose rate of pulsed radiation with a pulse duration of 10 ns (AT1123) The possibility of remote measurements using a remote control The possibility of stationary location with external audible and visual alarms with "dry" contacts for controlling actuators The possibility to connect to a PC for organizing a continuous monitoring system with a documentation function
Produced in: Belarus, Minsk
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Appointment Athlete KAI-2.1001 • Determination of the type of damage and the distance to the place of damage to the cable. • Tracing a cable line up to 10 km. • Determination of cable depth up to 6 m. • Troubleshooting of cable lines by induction method. • Troubleshooting of cable lines by acoustic method. • Cable insulation testing.
Produced in: Kolomna, Moscow region
Generator G3-131
Generator G3-131
Technical specifications: Frequency range, from 2 Hz to 2 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms , at least 5 V at least 10 V Smooth signal attenuation, at least 20 dB Frequency instability: - in 15 minutes - for 180 minutes, no more than 0.1% no more than 0.5 % Harmonic coefficient: - in the frequency range from 10 Hz to 20 Hz - in the frequency range sv. 20 Hz to 200 kHz - in the frequency range of 200 kHz to 2 MHz, not more than 0.5% not more than 0.2% not more than 1 %
MNIPI
Minsk
Produced in: Belarus, Minsk
"Home officer" Plus Kit
"Home officer" Plus Kit
from 61 620 ₽
Designed for: – measurement and registration of air temperature, temperature of hot water supply, surface of heating devices; – measurement and registration of relative humidity; – saving data to a memory card with subsequent transfer to a PC for generating reports; – measurement accuracy from ± 0.2 ° C.
Produced in: Moscow
Laboratory electronic thermometer LTA-K
Laboratory electronic thermometer LTA-K
A compact temperature sensor on an elastic cable allows you to get to the most inaccessible places of the certified equipment. LTA-K can be used as an accurate universal thermometer for contact temperature measurement of non-aggressive liquid, bulk and gaseous media. The error is ± 0.05 °C in the range of -50...+200 °C. Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Metolab 502 Vickers Hardness Tester
Metolab 502 Vickers Hardness Tester
The stationary METOLAB 502 hardness tester is a modification of the METOLAB 501 series device, equipped with a display and a digital micrometer that allows you to automatically read values without the need for conversion tables. The device also automatically calculates the hardness of the samples. The METOLAB 502 microhardometer is designed to measure the hardness of various samples and products (steels, cast iron, non-ferrous metals and soft alloys) according to the Vickers (HV) and Knup (HK) scales in full compliance with GOST R ISO 6507-1-2007. The device has high accuracy, performs measurements in a wide range and with high repeatability. The stationary automatic METOLAB 502 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 502 Micro-Vickers hardness tester: Built-in digital micrometer that allows you to automatically read readings without the need for translation tables; Automatic hardness calculation; Simple and intuitive control of the device, fully Russified menu; Wide range of measured values – from 5 to 2500 HV; A wide range of applied test loads - 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Large and bright LCD display. Basic delivery package: Stationary METOLAB 502 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; Large flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
AF18-20dB
AF18-20dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, 20 dB Attenuation error, dB ± 1.0 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
Dosimeter-radiometer ISS-17D "Finch"
Dosimeter-radiometer ISS-17D "Finch"
Purpose: measurement of the power of ambient dose equivalent (MAED) and ambient dose equivalent (ED) of photon radiation; operational search for sources of ionizing radiation and radioactive materials; measurement of the flux density and fluence of alpha and beta radiation; measurement of surface alpha and beta activity; measurement of the ambient dose equivalent (MAED) power of neutron radiation.
Doza
Zelenograd
Produced in: Moscow
Measuring air-thermal installation ASESH-8-1
Measuring air-thermal installation ASESH-8-1
1 supp.
A thermogravimetric (air-thermal) method for determining the mass fraction of moisture is implemented, based on measuring the mass of the sample of the analyzed substance before and after drying, followed by calculating the values of the mass fraction of moisture. Air-thermal measuring installations ASESH-8 are registered in the State Register of Measuring Instruments under No.58526-14, have a certificate of approval of the type of measuring instruments RU.C.31.005 And No. 56847. The installations undergo initial verification and have the appropriate certificate. GENERAL CHARACTERISTICS 1. Convenient access to the cells of the drying chamber On the front side of the cabinet there are four doors for access to the cells. 2. The possibility of simultaneous determination of the humidity of 8 samples The drying chamber of the air-heat installation consists of 8 independent cells with a total capacity of 16 bucs. 3. Built-in timer The ASESH-8-1 installation has 4 timers, by means of which the end of the drying process is monitored in each section with the output of an audible signal and a light indication. 4. Natural ventilation The absence of rotating elements ensures absolute noiselessness of operation and a long service life. SCOPE OF APPLICATION: 1. Crop production, agriculture and forestry. 2. Products of meat, dairy, fish, flour-milling, feed and microbiological industries. 3. Food industry products. 4. Cellulose, paper, cardboard and products made from them. 5. Medicines, chemical and pharmaceutical products and medical products. 6. Building materials. 7. Products of the logging and sawmilling and woodworking industry. 8. Soils, пground, mineral fertilizers.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg