VL-220M comparator scales
VL-220M comparator scales
from 274 990 ₽
Technical specifications NIP, g82/220 Discreteness, g0,00001/0,0001 Self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0,001 The price of the calibration scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * from 1mg to 10mg ± 0.2; from 10mg to 82g ± 0.1; sv. 82g ± 0.3 The setting time, seconds, no more - fast mode - 8/3; - standard mode - 10/6 Overall dimensions of the scales (LxWxH), mm356x220x338 7 years warranty Weight of the scales, kg, not more than 7.6 The weight adjustment is built-in
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
TPZ-LAB-12 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-12 is a built–in cooling unit capable of cooling the test cell to -85 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests to determine the temperature of turbidity and solidification, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 4.5 ml Temperature range of the test cell -85...+51°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 250 W Overall dimensions 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Table-sink LAB-M MO ME 120.65.90 T6F
Table-sink LAB-M MO ME 120.65.90 T6F
Furniture for laboratory work. Washing table on a metal support stand LAB-M MO ME 120.65.90 T6F Width:1200 Depth: 650 Height: 900 Equipment: Table top – TRESPA TopLabPlus - a monolithic slab of ultra-high pressing thickness of 6 mm with a chemically resistant surface made of polyurethane–acrylic composition, the lining material is moisture-resistant plywood 15 mm thick; the table top is edged with a dark gray plastic edge 1 built–in bowl - FRIDURIT ceramics. The location of the bowl in the center, fixing the bowl flush with the level of the countertop. Inner bowl size – 400*400*250 mm The base of the sink table is a metal support pedestal. All-welded frame painted with dark grey powder paint RAL 7011. The bottom and top of the housing are sheet steel painted with dark gray powder paint RAL 7011, the side walls are made of sheet steel painted with white powder paint RAL 9016. Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NVDM-160 High-vacuum Diffusion Pump
NVDM-160 High-vacuum Diffusion Pump
The operation of the NVDM-160 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-160 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-160 closed-type diffusion pump heater consists of tubular electric heaters fixed in the heater housing. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 40C to plus 250C. The recommended cooling water consumption is 60+10 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-160 pump are provided, must correspond to min 10mm, max 17mm. The volume of the filled working fluid is 0.3 liters
Produced in: Kazan
Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
Measurements in wide ranges of capacities doses and energies Measurement of dose rate and duration of exposure during short-term radiation from 0.03 s Measurement of the average dose rate of pulsed radiation with a pulse duration of 10 ns (AT1123) The possibility of remote measurements using a remote control The possibility of stationary location with external audible and visual alarms with "dry" contacts for controlling actuators The possibility to connect to a PC for organizing a continuous monitoring system with a documentation function
Produced in: Belarus, Minsk
Laboratory drying cabinets SHS-20/3,0
Laboratory drying cabinets SHS-20/3,0
The electric drying cabinet SHS-20/3,0 is designed for drying, heating various materials in an air environment at a maximum temperature of 300 ° C. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. Operating temperature- 300 ⁰C Power consumption - 2000 W Dimensions of the working chamber WxDxH- 195x480x195 mm Dimensions WxDxH- 325x760x445 mm Weight - 30 kg
MIUS
Tula
Produced in: Tula
CHEMA LABORATORY CHAIR
CHEMA LABORATORY CHAIR
from 21 670 ₽
Suitable for comfortable seating at tables from 750 to 900 mm high. It is possible to replace the standard gas lift with a high one, which will allow changing the height adjustment range of the chair from 570 to 820 mm and using such a chair to work at tables above 900 mm. The permissible load on the product should not exceed 120 kg. Seat size - 455x440 mm, backrest - 410x370 mm.
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Circulation thermostat LT-424a
Circulation thermostat LT-424a
The LOIP LT-424a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 24 The working fluid is water, silicone oil. Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 532x335x400 Weight, kg 15.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Table island high LAB-PRO SOCV 180.150.90 TR
Table island high LAB-PRO SOCV 180.150.90 TR
One-piece table top: TRESPA TopLabPlus 16 mm Length, mm: 1800 Depth, mm: 1500 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm) A set of end boxes-plugs
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory LAB table-1200 LT
Laboratory LAB table-1200 LT
PACKAGE CONTENTS case – melamine 16mm thick 1 drawer, inner drawer size – 400*470* 100mm 2 splash-proof sockets with cover (IP20 1.5kW) 2 automatic emergency power off 16A 2 all-welded frames made of rectangular metal profile painted with white powder paint adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
High-frequency signal generator G4-229
High-frequency signal generator G4-229
The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range (RF output) from 9 kHz to 6 GHz Frequency range (LF outputs) from 0.001 Hz to 30 MHz Frequency tuning discreteness (RF output) 1 Hz Frequency tuning discreteness (LF outputs) 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main RF output is from minus 120 to 13 dBm The range of setting the signal amplitude at a load of 50 ohms (LF outputs) from 0.01 to 5 V The basic error of setting the reference power level (RF output) ± (0.5 – 1.0) dB The basic error of setting the amplitude of sinusoidal signals (LF outputs) ± (3 – 15)% Instability of the signal power level for any 15-minute time interval (RF output) no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the basic error of setting the frequency deviation ± (10 – 20)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient (when operating from an internal signal source) ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow