Device for lifting and lowering samples LA-220
Device for lifting and lowering samples LA-220
Designed for immersion of objects in the baths of LOIP LT thermostats and LOIP LB-200 precision thermostatic baths to a predetermined depth. Thermostatable objects are placed on a movable pallet, which can be fixed at any required depth. The device is installed on the casing of thermostats and precision thermostatic baths instead of a hinged lid and is equipped with its own removable lid. Bath volume, l 17 and 24 Pallet size, mm 260x320 Maximum immersion depth, mm 200
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-316a
Circulation thermostat LT-316a
Technical specifications: Temperature range: without external cooling, °C Current+10 ... +150 with tap water cooling °C Tvods+5 ...+150 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 8,0 pressure, 0.25 bar Bath volume, l 16 Working fluid water, water-glycerin mixtures, silicone oil The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Weight, kg 12.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Leakage detector Success AT-207
Leakage detector Success AT-207
from 99 360 ₽
The kit of the portable acoustic leakage detector "Success AT-207" is designed to detect depressurization sites of underground pipelines of heat and water supply systems located at a depth of up to 3 m in channel and channel-free laying. The search for damage sites is carried out by the acoustic method. •
Produced in: Kolomna, Moscow region
Laboratory flask
Laboratory flask
from 190 ₽
Designed for filtration, evaporation, distillation, distillation, distillation and synthesis in laboratory conditions. Variants of execution: To-2-100-22 TU 9464-019-29508133-2015 To-2-100-34 , TU 9464-019-29508133-2015 TO-2-1000-42 TU 9464-019-29508133-2015 To-2-2000-50 TU 9464-019-29508133-2015 To-2-250-34 TU 9464-019-29508133-2015 To-2-50-22 TU 9464-019-29508133-2015 TO-2-500-34 TU 9464-019-29508133-2015
MiniMed
Suponevo
Produced in: Bryansk region
GAS PANEL
GAS PANEL
The gas distribution panel (hereinafter referred to as the panel) is designed to connect gas nodes and blocks of various analytical instruments, including chromatographs to shop gas lines. technical specifications Inlet pressure, not more than 0.8 MPa. The output pressure is from 0 to 0.4 MPa. Gas flow rate through each channel, not less than — 1000 cm3/min.
Produced in: Yoshkar-Ola, Mari El
SPEAKER SWITCHING DEVICES
SPEAKER SWITCHING DEVICES
To switch the nozzle columns, conventional taps (reverse purge, 6-, 8- and 10-port) are used, which, however, are not suitable for switching capillary columns. An alternative way to switch capillary columns is to change the flows in the capillary columns, which is produced by the so-called "Dins switches" (PD). TECHNICAL CHARACTERISTICS of PD The switching time setting range is from 0.1 to 999 min. Switching time is 0.1 s. The dead volume of the crane is less than 1 µl. The temperature of the tap is no more than 350 °C. The pressure in the crane line is not more than 0.4 MPa. Electric power supply — 5 V.
Produced in: Yoshkar-Ola, Mari El
Flame Photometric(FD)
Flame Photometric(FD)
Selective detector for phosphorus and organosulphide compounds. It is used mainly for the analysis of sulfur-containing substances (hydrogen sulfide, mercaptans, thiophenes, etc.). The sensitivity for sulfur reaches 0.1. ppm. In addition, PFD has sufficient sensitivity and selectivity to compounds containing nitrogen, boron, tin, chromium, selenium, germanium, as well as CO, POPS, MgOx, $02, Ma, NOT C52. The selectivity of 5-containing compounds to hydrocarbons is 105. Technical characteristic: 8,0*10-13 g5/s by sulfur 1.0*10`13 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
Electronic Gripper (E3D)
Electronic Gripper (E3D)
Selective detector for organochlorine compounds and other halogens. It is also sensitive to compounds containing oxygen, phosphorus or aromatic rings, but to a lesser extent. Paraffins and simple hydrocarbons almost do not capture electrons and are not registered. The selectivity to hydrocarbons is 108. It is available in two versions — conventional EDD and micro-EDD, mainly for capillary columns (the second version is characterized by increased sensitivity). The level of fluctuation noise is up to 300 MV, the maximum signal is up to 5 V, the design of the ECD allows the use of argon, helium, and hydrogen as a carrier gas, in addition to nitrogen. Technical characteristic: 4.0*10-15 g/s for lindane
Produced in: Yoshkar-Ola, Mari El
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
Thermionic (TID)
Thermionic (TID)
Selective detector for organophosphorus and nitrogen compounds. It is also sensitive to compounds containing C, Az, but to a lesser extent. The sensitivity depends on the number of heteroatoms in the molecule. Selectivity to hydrocarbons is 104 for nitrogen, and 105 for phosphorus Technical characteristic: 2.0*10-13 m/s nitrogen 1.5*10`14 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
Pulsating Discharge Detector(PRD)
Pulsating Discharge Detector(PRD)
It operates in the mode of a helium ionization detector (GID) and is considered the most sensitive device for determining permanent gases. In addition, it is able to work in the EDD mode. Technical characteristic: 2.0*10`13 g/s by. methane or hydrogen
Produced in: Yoshkar-Ola, Mari El