Atomic Emission Complex "Grand Stream"
Atomic Emission Complex "Grand Stream"
Atomic Emission Complex "Grand Stream" is designed for rapid determination of the composition of powder samples of natural and industrial origin, includes a "Grand" spectrometer, a "Stream" installation and auxiliary equipment for sample preparation.
Produced in: Novosibirsk
CWDM SFP Modules (1.25Gb/s) /Gigabit Ethernet/SD-TTL
CWDM SFP Modules (1.25Gb/s) /Gigabit Ethernet/SD-TTL
A dual-fiber optical transceiver (SFP CWDM transceiver), SM, 1.25 Gb/s, LC connector, hot-swappable.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
PipeScope 60-170 Portable Rapid Diagnostics System for Drill Pipes
PipeScope 60-170 Portable Rapid Diagnostics System for Drill Pipes
Technical characteristics of PipeScope 60-170 Pipe inspection time in the installation is no more than 30 seconds The diameter range of controlled pipes is 60 mm – 170 mm The range of wall thicknesses of controlled pipes is up to 20 mm The length of the controlled pipes is 1..13 m The maximum time of continuous operation per day is up to 24 hours Rated power supply voltage is 50 Hz, 220 V The working gap between the sensor and the control object is up to 0.5 mm Operating temperature range is -40 °C... +40 °C The number of measuring channels for searching for defects using the magnetic flux scattering method is up to 128* The number of measuring channels for defect detection and thickness measurement using the flow density measurement method is up to 96* Pipe diameter measurement error 0.05% The measurement error of the length of the controlled pipe is 10 cm The possibility of demagnetization of the pipe after control in automatic and manual modes is availiable The coverage of the continuity of control along the perimeter of the pipe is 100% The changeover time of the installation to another BT standard size is no more than 30 minutes. The speed of movement of the flaw detector trolley through the pipe is from 0 to 0.9 m/s Power consumption is up to 1 kW Installation weight  Trolley with basket — no more than 11 kg Magnetization coil — no more than 10 kg Air lift — no more than 72 kg Minimum size of detectable defects In accordance with DS-1 Minimum signal-to-noise ratio for drilling with a diameter of 1.6 mm In accordance with DS-1 The error in determining the linear coordinate of the defect is not more than 5 cm The error in determining the angular coordinate of the defect is no more than 4 degrees ° Installation control complies with the following standards in terms of its characteristics: API Spec 5D, API RP7G, DS- 1 Overall size and weight of PipeScope 60 — 170 Ultra Pro in transport containers without SOP and without pneumatic lifts 600 mm X 600 mm X 600 mm / 32 kg Overall size and weight of the air lift in a transport container is 1300 mm X 300 mm X 300 mm / 72 kg Overall size and weight of the SOP in a transport container is 1900 mm X 210 mm X 210 mm / 60 kg
Oktanta
Saint Petersburg
Produced in: Saint Petersburg
Smart probe of relative humidity and temperature L=500 mm SSVL.500
Smart probe of relative humidity and temperature L=500 mm SSVL.500
from 15 801 ₽
The smart probe of relative humidity and temperature L=500 mm SSVL.500 is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.500 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.500 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
ION-3701 Version "North"
ION-3701 Version "North"
from 77 245 ₽
A small-sized digital magnetometer (gaussmeter, teslameter), a residual magnetization meter ION-3701 version "North" is a modern high-precision device (a variant of the ION-3701 device) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization in adverse climates, conditions of negative temperatures, the Far North and etc . It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Clamping clamps for ultra sealing rings
Clamping clamps for ultra sealing rings
Size of DN: 10,16,20,25,32,40,50. Crimping rings (aluminum) for rings with high sealing capacity.
Produced in: Kazan
RT and RT-PCR
RT and RT-PCR
from 4 520 ₽
Reverse Transcriptase RNAscribe RT Reverse transcriptase M-MuLV–RH A set of reagents RT-M-MuLV-RH with primers RNAscribe RT Plus BioMaster (5×) RT-PCR RT-PCR with real-time detection: BioMaster RT-qPCR (2×) BioMaster RT-PCR SYBR Blue (2×) BioMaster RT-PCR-qPCR-Extreme (2×) RT-PCR with endpoint detection: BioMaster RT-PCR-Standard (2×) BioMaster RT-PCR–Premium (2×) BioMaster RT-PCR–Extra (2×) BioMaster RT - PCR– Premium - Color (2×) BioMaster RT-PCR – Color (2×)
BIOLABMIKS
Novosibirsk
Produced in: Novosibirsk
Droplet separator
Droplet separator
The drip collector is designed to remove droplet moisture when sampling air from indoor ventilation systems and is installed in gas aerosol sampling systems. Purpose: removal of droplet moisture from the selected air sample; accumulation of droplet moisture; indication of the level of accumulated moisture; draining the accumulated moisture.
Doza
Zelenograd
Produced in: Moscow
CS20-20 power supply
CS20-20 power supply
Operating Mode: Continuous Output stabilized current, A: 0-20 Output voltage, V: 0-20 Power supply: Single-phase 220 V 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 3 Overall dimensions (W x H x D), mm: 205 x 200 x 80
INZHEKT
Saratov
Produced in: Saratov
Holder THERMOTEST-D1-3/9
Holder THERMOTEST-D1-3/9
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm. It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
Produced in: Tomsk
Vacuum drying cabinet with automatic control SNVS-1000/3.5
Vacuum drying cabinet with automatic control SNVS-1000/3.5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula