Search

4123 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 541
    Names
    Loading...
  • 123
    Manufacturer
    Loading...
  • 58
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
4123 products
IMD-2NM Dose Rate Meter
IMD-2NM Dose Rate Meter
Measures: - the power of the absorbed dose of gamma radiation in a tissue equivalent substance with radiation thickness of 1 g/cm2; - contamination of surfaces with beta-nuclides (beta radiation flux density): in the energy range from 0.08 to 3.0 MeV in the energy range from 0.3 to 3.0 MeV Measurement of radioactive emissions: - in the measurement ranges of absorbed dose rate: - with the BDZS-10S detection unit; - without the BDZS-10S detection unit; - in the range of measuring the beta radiation flux density with the BDZS-10S detection unit from 10 mkrad/h to 999 rad/h from 10 mrad/h to 999 rad/h 10...999·102 parts/cm2min The meter is resistant to the background of gamma radiation from the 137Cs source when measuring the contamination of surfaces with beta-active substances, depending on the measurement ranges: from 10 to 102 parts/cm2min: absorbed dose rate is no more than 0.1 mrad/h from 102 to 103 parts/cm2min: absorbed dose rate is no more than 1.0 mrad/h from 103 to 104 parts/cm2min: absorbed dose rate is no more than 10.0 mrad/h from 104 to 105 parts/cm2·min: absorbed dose rate is no more than 100 mrad/h Limits of permissible basic error: - when measuring the absorbed dose rate of gamma radiation under normal climatic conditions from a second-class caesium-137 source relative to the measured value with a confidence probability of 0.95: the permissible basic error does not exceed ± 20% (at release) and ± 25% (during operation) - when measuring the absorbed dose rate of gamma radiation from 10 to 100 mrad/h under normal climatic conditions using a second-class caesium-137 source with a measuring console UI-177S without using BDZS-10C relative to the measured value with a confidence probability of 0.95: the permissible basic error does not exceed ± 20% (at release) and ± 25% (during operation) - when measuring the beta radiation flux density under normal climatic conditions from a second-digit strontium-90 + yttrium-90 source relative to the measured value with a confidence probability of 0.95: the permissible basic error does not exceed ± 20% (at release) and ± 25% (during operation) The mass of the meter is no more than 3.76 kg
Produced in: Kaluga region, Obninsk
Explosion-proof vacuum electric furnace START-215
Explosion-proof vacuum electric furnace START-215
Vacuum resistance furnaces are necessary for heating products before pressure treatment, for sintering, degassing, quenching, annealing, soldering and chemical-technological processes. Such furnaces among all the variety of thermal equipment are considered the most environmentally friendly – heat treatment is carried out at t up to +2500 ° C in a purified vacuum. Under certain conditions, vacuum furnaces are used to work with neutral gases. The outer part of the furnace is made of stainless steel and is cooled by liquid. The inner part of the working chamber, where the heat treatment of materials is carried out, is made of an alloy of molybdenum and tungsten. The components are characterized by a low inertia force, reduced gas separation. The settings are available on the control panel, where the instruments, automatic and manual control switches are located. At every enterprise of the electronic industry, nuclear power, an explosion-proof vacuum resistance furnace is needed. The same applies to areas where various products undergo heat treatment at the stage of production and preparation for use
Produced in: Tula
Vacuum tube MiniMed without filler, 5 ml, 13×100 mm, red, PTFE, pack.100 pcs
Vacuum tube MiniMed without filler, 5 ml, 13×100 mm, red, PTFE, pack.100 pcs
from 649 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Smart probe of relative humidity and temperature L=150 mm SSVL.150P with built-in flash memory
Smart probe of relative humidity and temperature L=150 mm SSVL.150P with built-in flash memory
from 13 740 ₽
The smart probe of relative humidity and temperature L=150 mm with a built-in flash memory is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.150P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
NV-1500 SM-B Table for microscopy (1500×700×750)
NV-1500 SM-B Table for microscopy (1500×700×750)
from 8 852 ₽
The NV-1500 SM-B is a specialized table for microscopy. The table top is 70 cm deep with a small cutout made of laminate. It is designed for sitting work: the height from the floor to the countertop is 75 cm (this is the height of a regular office desk). External dimensions of the table (W×D×H): 1500×700×750 mm. A small superstructure allows you to compactly place the necessary drugs and accessories next to the workplace. Its dimensions: (W×D×C): 668×120×200 mm. The table top is made of laminated chipboard. It is relatively moisture-resistant, resistant to short-term exposure to acids, alkalis and organic solvents and is well suited for the placement of devices. There is a small semicircular cutout on the front of the table top, which allows you to work more comfortably with the microscope. The side laminated panels of the table (chipboard 16 mm thick) are edged with a PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
SHGS-2 TWO-PIECE LOCKER
SHGS-2 TWO-PIECE LOCKER
from 26 600 ₽
The arrangement of the locker room is required both in factories, laboratories and other production sites, and fitness centers. Two main requirements are most often applied to lockers – durability and aesthetics, which directly affect the mood of employees or visitors. Choose really high–quality furniture for your organization - it's not difficult with Simple PRO. Width - 400
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
OZIS PHARMA PH 41 Tablet press
OZIS PHARMA PH 41 Tablet press
Productivity, thousand tab./hour 209 Number of stations 41 Max. pressing force, tn 10 Number of threads 2 Diameter of tablets, mm 6-20 Height of tablets, mm 1.5-9 Matrix filling depth, mm 18 Rotor material steel 40x13 Filling hopper capacity, l 20(30) Stepless rotor speed change The change in the speed of rotation of the feeder is independent Supply voltage 380V, 50Hz Power consumption, kW/hour 5.78 Weight, kg 2400 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Aquadistillator electric DE-70
Aquadistillator electric DE-70
from 182 000 ₽
Purpose: obtaining distilled water of 3 types according to GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Capacity: 70.0 (-10%) l/h Heating elements: electrodes The quality of the produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current, frequency, voltage: alternating three-phase, 50 Hz, 380 V Power consumption: 42.0 kW Overall dimensions (L×W×C), mm: 740×550×1010 Weight: 64 kg Warranty period: 14 months from the date of sale Registration certificate for a medical device No. FSR 2008/03707 dated December 05 , 2008 Electrical conductivity of the produced water: 3-4.5 microns/cm The temperature of the produced water: 50 °C Source water flow rate (at 10 °C water temperature): 500 (+-10%) l/h Source water pressure: 0.1-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 400×220×500 Execution: outdoor Coefficient of water purification from radionuclides: at least 4000 Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
 VD-41P Eddy Current Flaw Detector
VD-41P Eddy Current Flaw Detector
Scope of application The VD-41P eddy current flaw detector is designed to work as part of automated quality control lines at pipe-rolling and metal-rolling enterprises with continuous output control of products together with other auxiliary devices: a paint meter, a path sensor, an object presence sensor, an automatic sorter, a demagnetizer. The device can also be used for input control at machine-building enterprises of the automotive, aviation, oil and gas, and agricultural industries. Technical specifications: Control frequencies: 1.0 – 100 kHz. Control speed (line speed): 0.5 - 5 m/s. The high-frequency filter is automatically adjustable depending on the speed. Signal phase adjustment: 0 - 359° . Converter current adjustment: 50 – 500mA. Automatic monitoring of the operability of the measuring converter. Data processing: - Software adjustable filter. - Signal evaluation using signal masks: - circular mask, - sector masks. - Sorting by control results. Display: 10.2” (26 cm) touch LCD (800x600). Operating system used: WINDOWS® 7. Dialog language: Russian, other languages (optional). Applicable eddy current converters: overhead type, through type, sector type. Interfaces: - Connector for the converter unit. - External automation control connector. - 4 outputs with delay adjustment - "dry contact". - 2 external information inputs. - VGA interface for connecting an external monitor. - USB 2.0. - Network: Ethernet (TCP/IP). - Other interfaces on special order. Power supply: 220 V, 50 Hz. Operating temperature range: 0 to +40°C. Type of climatic performance - UHL 4 (i.e. for moderate and cold climate). Enclosure protection degree: IP 53. Dimensions, w/h/d: 471 x 285 x 460 mm / can be built in a 19” rack/cabinet. Weight: approx. 20 kg.
Produced in: Moscow
Blue Laser pointers KLM-P450-x-3
Blue Laser pointers KLM-P450-x-3
Blue laser pointers of the KLM-P405-10-3 series with a collimated beam of low divergence radiation are optimal sources for demonstration purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-111a
Circulation thermostat LT-111a
The LOIP LT-111a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Water+5 ... +100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, bar 0.17 Bath volume, l 11 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 160x240/200 Overall dimensions, mm 268x335x420 Weight, kg 10
LOIP
Saint Petersburg
Produced in: Saint Petersburg