Device for preparation of graphite electrodes Crater-2
Device for preparation of graphite electrodes Crater-2
A machine for the preparation of graphite electrodes Crater-2. Two types of cutters can be installed simultaneously in the machine, for example, on a crater and a cone.
Produced in: Novosibirsk
Electric tubular laboratory furnace for work at a temperature of 1300℃ - SUOL 0,3.4/13
Electric tubular laboratory furnace for work at a temperature of 1300℃ - SUOL 0,3.4/13
from 724 480 ₽
Designation: SUOL 0,3.4/13 Temperature: 1300 Control: TRM-10 Number of zones: 1
Produced in: Tula
Table-sink LAB-1400 COULD
Table-sink LAB-1400 COULD
PACKAGE CONTENTS table top – laminate 1 built–in bowl - polypropylene Attention! It is not recommended to use the inner size of the bowl for work with oil and petroleum products (fuel oil, bitumen, etc.) – 400*400* 300mm cabinet body – melamine 16mm thick
LOIP
Saint Petersburg
Produced in: Saint Petersburg
SAC1000 Lenses
SAC1000 Lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 5.8±0.02 Height, mm: 1.5±0.02 Thickness, mm: 1.0±0.01 Refractive index, mm: 1.823 Pitch, mm: 1.0 Radius, mm: 6.52 Effective focal length, mm: 8.01 Rear focal length, mm: 7.45 Transmission, %: >99.5 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: 0.056 Surface quality at λ = 633 nm: λ/4 Residual deviation at full angle FW1/e2 (for non-linear deviation of the laser diode), mrad: 12.5
INZHEKT
Saratov
Produced in: Saratov
Laboratory wall-mounted high table SL-90.80.90
Laboratory wall-mounted high table SL-90.80.90
A 900 mm high table with a 900×800 mm countertop made of porcelain stoneware, monolithic ceramics, stainless steel, chipboard or plastic. It is designed for standing work. It can be equipped with various superstructures, sliding and hanging bollards. Overall dimensions 900x800x900 mm
Produced in: Tomsk
Vacuum tube MiniMed with K2-EDTA and separation gel, 3 ml, 13×75mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA and separation gel, 3 ml, 13×75mm, purple, PET, pack.100 pcs,
from 858 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Pressure gauge MTIf-100
Pressure gauge MTIf-100
Pressure gauge with a range of measured pressure 0 ... 100 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm
Produced in: Tomsk
High mezzanine to storage cabinets LAB-M Av 80.50.70
High mezzanine to storage cabinets LAB-M Av 80.50.70
Furniture for laboratory work. The mezzanine is high to the storage cabinets Length, mm: 800 Depth, mm: 500 Height, mm: 700 PACKAGE CONTENTS housing – white melamine with a thickness of 16 mm facades – white melamine, ABS edge dark gray 1 compartment without locks 1 removable shelf (height adjustment at 3 levels) the permissible load on the shelf is 20 kg the handle-bracket is dark gray 128 mm, polypropylene.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Adapters
Adapters
For pipes with DN: 10,16,20,25,32,40,50.
Produced in: Kazan
MX-10 Magnetometer
MX-10 Magnetometer
from 67 000 ₽
The MX-10 magnetometer is an auxiliary tool for conducting magnetic powder control using permanent magnets, rectified current electromagnets by the applied field method, as well as for monitoring by the residual magnetization method according to the requirements of the current regulatory documentation. The MX-10 magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities, etc. Magnetometer MX-10 is an electronic measuring unit with a remote measuring converter, which is based on the Hall effect. The design of the device allows measuring both the normal and tangential component of the magnetic induction vector directly on the surface of the part. The measured value of the magnetic field induction value is displayed on the digital indicator of the electronic unit. Features and Benefits The updated version of the MX-10 magnetometer has a modern element base, which has significantly improved its performance, reduced error and expanded the measurement range (see the Table of Technical characteristics). The device is capable of operating in two modes: Constant measurement mode. This is convenient when carrying out a large number of measurements over a short period of time. Automatic shutdown mode 1 minute after measurement. It allows you to save the charge of the device, which is especially important in the field. A thermal compensation circuit ensures stable measurement readings at any temperature change. Other features include: The small dimensions of the Hall measuring transducer for the MX-10 magnetometer make it possible to measure the induction of the magnetic field in grooves, grooves, angular transitions, i.e. in those areas of the controlled product that are stress concentrators and are most dangerous from the point of view of cracking; A wide range of measurements of the magnitude of the magnetic field induction; The smallest measurement error among analogues in the entire operating temperature range; Convenience of measurement by a remote measuring transducer in various planes; Low power consumption and, as a result, long working time; Low cost compared to similar models on the market; Compact dimensions; Manufacturer's warranty – 12 months; The device is included in the state register of measuring instrument RU.C.27.004.A No. 36079 dated 01.09.2009 and has undergone a verification procedure. Magnetometer MX-10 (milliteslameter) it is also included in the register of measuring instruments, test equipment and measurement methods used in JSC "Russian Railways". Scope of application 1. Verification of the magnetization modes of controlled parts using permanent magnets, rectified current electromagnets by the applied field method, as well as during the control by the residual magnetization method, by measuring the tangential and normal components of the magnetic field strength vector at one or more points on the surface of these parts. The number of points at which the magnetic field strength is measured and their location on the controlled surface depend on the shape of the part, as well as on the type and design of the magnetizing device used. 2. Control of the magnetization of parts before welding. During electric arc welding of non-magnetized parts, the effect of "magnetic blowing" is observed, i.e. the deviation of the electric arc from the axis of the electrode, the wandering of the arc end along the product, which leads to metal splashing during welding, deterioration of the seam quality. Therefore, before welding, it is necessary to measure the level and direction of magnetization of the parts and demagnetize them if necessary. 3. Verification of the residual magnetization after magnetic powder inspection. Demagnetization and verification of the residual magnetization of responsible, rubbing parts, as well as parts in contact with them after assembly, is prescribed in the requirements of the IPC and is a technological stage of control. 4. Magnetization control before assembling various structures. Magnetized parts can affect the operation of automation devices, cause errors in the readings of instruments, equipment. Magnetization can cause the accumulation of wear products in the movable joints, cause a negative effect on subsequent technological operations. Due to possible undesirable consequences, the parts are demagnetized and the quality of their demagnetization is checked. 5. Control of gas and water meters. Housing and utilities enterprises may also be interested in the device. It is known that existing gas or water flow meters can be easily "deceived" with the help of strong permanent magnets that reduce the rotation speed of the flow sensors. There are different ways to detect such theft. One of them is the control of the residual magnetization of the counters using magnetometers. The measured value should not significantly exceed the Earth's magnetic field, otherwise it can be concluded that there was unauthorized interference with the operation of the device. Main technical characteristics Measuring range, MT from 0.1 to 100 The limits of the permissible basic absolute measurement error, MT D = 0.02 VI + 0.05, where VI is the magnetometer readings in MT Power supply battery type: PP3 (nine-volt battery) Consumption current, mA, no more than 15 Duration of continuous operation (from fully charged batteries), h, at least 20 Overall dimensions, mm: – electronic unit (LxWxH) 120x60x25 – Measuring transducer (Diameter x Length) 18x173 Weight, g, not more than 160 Ambient operating temperature, °C -10...+40
Produced in: Moscow