Search

4008 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 25
    Foreign brand
    Loading...
  • 46
    By name of foreign product
    Loading...
  • 525
    Names
    Loading...
  • 4008
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 131
    Manufacturer
    Loading...
View:
4008 products
Optical set-top box for working with light-guide IR probes
Optical set-top box for working with light-guide IR probes
FT-801 IR Fourier spectrometers can additionally be equipped with a special optical set-top box that allows efficient use of light-guide systems. 4 types of light-guide probes allow measuring transmission and reflection spectra in solid, liquid and gaseous media Modern IR light guides have high intrinsic transmittance and sufficient mechanical strength, which makes it possible to transfer measurements from the laboratory directly to production - to control the flow of technological processes, check the quality of raw materials and finished products. Application areas: · Chemical and microbiological industry · Pharmaceutical industry · Medicine and Cosmetology · Food industry · Petroleum products, fuels and lubricants · Criminology
SIMEKS
Novosibirsk
Produced in: Novosibirsk
NV-1250 SHV-BC Fume cupboard with countertop made of monolithic ceramics
NV-1250 SHV-BC Fume cupboard with countertop made of monolithic ceramics
from 46 412 ₽
THe Kors NV-1250 SHV-BC laboratory fume cupboard is a single—frame cabinet with a width of 1240 mm and with a table top made of monolithic ceramics. External dimensions of the cabinet (W×D×H): 1240×700×1960 mm. Dimensions of the working area (W×D×H): 1208×660×1072 mm. Table top: monolithic ceramic. Convenient fume cupboard for comfortable work in the laboratory The table top made of monolithic ceramics is moisture-resistant, perfectly withstands high temperatures. Due to the lack of seams, ceramic granite tiles are better resistant to chemicals and heat. It is possible to place high-temperature equipment on it. The working area is closed by a single lifting frame with a counterweight. There are two exhaust zones in it: the hood of the exhaust box and the level of the countertop. Diameter of the flange for connection to the ventilation system: 150 mm. Working area size (W×D×H): 1208×540×750 mm. Please note that the cabinet narrows upwards. At a height of 50 cm, the depth of the working area will be 410 mm, at a height of 70 cm it will be 365 mm. If you need to place high equipment, then make sure that it corresponds to the dimensions of the camera, otherwise you will not be able to close the cabinet. The height of the raised glass above the cabinet: 510 mm, that is, when the glass is raised, the height of the cabinet will be 2470 mm. The working area is illuminated by a fluorescent lamp (included in the package). The switch is located on the right side of the cabinet, next to the sockets. The fume cupboard is equipped with two sockets, one of them with grounding. Sockets have the IP20 degree of protection, maximum load: 1.5 kW. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a durable PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The cabinet legs are adjustable in height within two centimeters, allowing you to place the cabinet even on a rather uneven floor. And if we need a cabinet for muffle furnaces? If you need a cabinet to accommodate high-temperature equipment, you might be interested in the ballscrew models. The depth of the countertop is specially increased so that you can put an oven or a cabinet.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Installation for obtaining analytical quality water UPVA-5
Installation for obtaining analytical quality water UPVA-5
from 115 000 ₽
Capacity, l/h 5.0 (-10%) Purpose preparation of distilled water of type 2 according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 3.5 kW 220V (stainless steel) – 1 pc. The quality of the produced water GOST 52501-2005 "Water for laboratory analysis", FS.2.2.0019.18 "Water for injection" Type of current, frequency, voltage alternating single-phase, 50 Hz, 220 V Power consumption, kW 3,6 Overall dimensions (L×W×C), mm 424x417x454 Weight, kg 20,0
Livam
Belgorod
Produced in: Belgorod
3VVN1-3M(N) Water ring vacuum pump
3VVN1-3M(N) Water ring vacuum pump
The 3VVN1-3M(N) water ring vacuum pump with a capacity of 3.5 m3/min at an initial pressure of 0.04 MPa is designed for general industrial use, to create and maintain a vacuum in the operating pressure range from atmospheric to 10 kPa. The working fluid of the pump is water. The use of the 3VVN1-3M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working organs. The 3VVN1-3M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-3M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
Vacuum tube MiniMed with K3-EDTA, 6 ml, 13×100mm, purple, glass, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 6 ml, 13×100mm, purple, glass, pack.100 pcs
from 988 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Table-sink LAB-M MO 80.65.90 F20
Table-sink LAB-M MO 80.65.90 F20
Furniture for laboratory work. Table-sink LAB-M MO 80.65.90 F20 Width, mm: 800 Depth, mm: 650 Height, mm: 900 Equipment: Table top – monolithic laboratory ceramics FRIDURIT 20 mm (one-piece seamless glazed plate without a rim, color light gray) 1 built–in bowl - FRIDURIT ceramics. The location of the bowl in the center, the mounting of the bowl is overhead. Inner bowl size – 400*400*250 mm The base of the sink table is a support pedestal made of white melamine Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging Without shelves
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cylindrical tube without stopper, 10 ml,16*100 mm, p/c,according to TU 9464-015-29508133-2014, pack.500pcs
Cylindrical tube without stopper, 10 ml,16*100 mm, p/c,according to TU 9464-015-29508133-2014, pack.500pcs
from 2 400 ₽
Intended for taking, storing and transporting samples of biomaterials for further diagnostic studies in clinical laboratories.
MiniMed
Suponevo
Produced in: Bryansk region
Universal optical set-top box with zinc selenide element and integrated visualization system on an external monitor
Universal optical set-top box with zinc selenide element and integrated visualization system on an external monitor
It is intended for express analysis of various types of solid and liquid samples, including polymer particles, films and fibers, powdery substances, fragments of paint coatings, fuels and lubricants. The presence of an optical system for visual inspection of the surface under study with an increase of 75X ensures high efficiency when working with small samples – fragments of thin fibers, microparticles, etc. The universal clamp is equipped with a precision lever mechanism for quickly lowering the tip and a micrometer screw that allows you to pre–set the optimal degree of pressure - this ensures quick sample change and repeatability of the results during measurements. For convenience when working with liquid and paste-like samples, as well as in the ZDO mode, it is possible to rotate the clamping console by 180o. The console is equipped with two replaceable tips – with a spherical working part and with a flat hinged head. A replacement table is used to register the specular and diffuse reflection spectra. The sample is located on the subject plane of the investigated surface downwards, the angle of incidence of the central beam on the sample is 45 °. The method is used to determine the spectral characteristics of optical parts, crystals, thin films on the surface, as well as to register the absorption spectra of large solid objects. Transmission in the operating range of the spectrum, % of the input signal at least 30 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 The depth of penetration of radiation into the sample, microns 5 – 15 Minimum area of a solid sample, mm 0.2 × 0.2 Minimum volume of the liquid under study, ml 1 Minimum dimensions of the fiber sample: cross-section diameter/length, mm 0.1/1 Substrate crystal material ZnSe CVD, Ge Focusing spot diameter, mm 1 The angle of incidence of radiation (central beam) on the sample in the ZDO mode 45o Magnification of the micro lens / total magnification of the visual channel 4X /75X Field of view of the optical system, mm 2 X 2.5 Digital video camera resolution 640 X 480 Overall dimensions, mm 150×150×260 Weight, kg 2.15 • Allows you to study objects of small size (from 200 microns - depending on the geometry, surface quality and physico-chemical properties of the material) • The attachment allows you to work without sample preparation, has a fixed adjustment of the pressure on the sample using a clamp equipped with color indicators • Thanks to the removable flange with the NPVO element, a quick and convenient sample change and cleaning of the crystal surface is provided • At a given optimal contact force, the method provides high quality and repeatability of results due to the absence of influence of the thickness of the substance layer on the shape of the spectrum and the intensity of the absorption bands • The sample retains its original physical and chemical properties and, if necessary, can be further investigated by other methods
SIMEKS
Novosibirsk
Produced in: Novosibirsk
ND-500 High-vacuum diffusion pump
ND-500 High-vacuum diffusion pump
The working condition of the ND-500 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-500 diffusion pump is a maximum of 5.5 liters, a minimum of 4 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change.The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of the heaters in the ND-500 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-500 diffusion pump up to 320°C, the temperature sensor should give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be carried out only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4 ° C to plus 25 ° C. The recommended cooling water consumption for the housing is 500 l/h, for the oil reflector it is 50 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break). The required speed of action of pre-vacuum pumps at a pressure of 26 Pa (0.2 mm Hg.st) in the outlet section of the ND-500 diffusion pump should be at least 42 l/s. To reduce the losses of the working fluid of the ND-500 diffusion pump at pressures (1·10-1- 1) Pa [(7,5·10-4- 7,5·10-3) mmHg] it is recommended to install an additional LP-500 flow-through water trap on the outlet flange.
Produced in: Kazan
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Appointment: continuous pumping of atmospheric air with a constant flow rate through a filter element based on Petryanova fabric. measurement of ionizing radiation parameters at a controlled point in accordance with the capabilities of the unit used.
Doza
Zelenograd
Produced in: Moscow
Modular liquid cooling unit VCHV-20
Modular liquid cooling unit VCHV-20
from 329 585 ₽
Designation VCHV-20 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 20 Required pump capacity, m3/h 4,5 Pressure loss in the heat exchanger, kRa 60
Produced in: Tula