Search

58 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 3
    Applying
  • Names
  • 2
    Manufacturer
  • 3
    Made in
  • 8
    Additional
View:
58 products
Laboratory scales VLTE-310S
Laboratory scales VLTE-310S
from 87 490 ₽
Technical characteristics: NIP, G310 Discreteness, g0,001 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Adjustment weight built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-8201S
Laboratory scales VLE-8201S
from 154 990 ₽
Technical characteristics: NIP, G8200 Discreteness, g0,1 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5g to 5000g incl. ±500; sv. 5000g to 8200g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 300 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~0.7 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-224V-S
Analytical scales VL-224V-S
from 217 490 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ±1.0; sv 200 to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 Adjustment weight built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-84V
Analytical scales VL-84V
from 184 990 ₽
Technical characteristics: NIP, G82 Discreteness, g0,0001 Internal calibration The smallest weighing limit, g0.01 The diameter of the scale bowl, mm91 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 82g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-2100T
Technical laboratory scales VLTE-2100T
from 27 490 ₽
Technical characteristics: NIP, G2100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2KGF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 77 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-410T
Technical laboratory scales VLTE-410T
from 34 990 ₽
Technical characteristics: NIP, G410 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.2 The limits of the permissible error during the initial verification, mgot 0.2g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 410g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 200gF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-1100P-V
Technical laboratory scales VLTE-1100P-V
from 37 490 ₽
Technical characteristics: NIP, G1100 Discreteness, g0.05/(0.02)* Internal calibration The size of the scale bowl / platform, mm175 x 145 The smallest weighing limit, g2.5 Limits of permissible error during primary verification, mgot 2.5g to 500g incl. ±50; sv. 500g to 1100g incl. ±100 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-320S
Analytical scales VL-320S
from 214 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, seconds, no more - fast mode - 3; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty Price with VAT, rub214,990
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-12 platform scales
RUNWAY-12 platform scales
from 69 990 ₽
Technical characteristics: NIP, kg12 Discreteness, g0.5/(0.2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 12 kg ± 1.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-84V-S
Analytical scales VL-84V-S
from 192 490 ₽
Technical characteristics: NIP, G82 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 82g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range of the time of setting the readings, s, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-310P-V
Technical laboratory scales VLTE-310P-V
from 47 490 ₽
Technical specifications: NIP, g310 Discreteness, g0,005/(0.002)* Internal calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0,1 The limits of permissible error during initial verification, mgot 0.1g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg