Search

23 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 4
    Applying
  • Names
  • 3
    Manufacturer
  • 5
    Made in
  • 1
    Additional
View:
23 products
ASKRO: Automated radiation monitoring system
ASKRO: Automated radiation monitoring system
The installations are designed for continuous monitoring of the radiation situation at specified points of radiation objects with data transmission via VHF radio frequency channel and/or GSM/GPRS network. Purpose: radiation monitoring of industrial sites of nuclear power plants and other radiation facilities (RCP); radiation monitoring of the environment of sanitary protection zones and observation zones (RCOS); creation of an automated system for monitoring the radiation situation (ASKRO) of territories, sanitary protection zones (SPZ) and monitoring zones (ZN) of radiation-hazardous objects; creation of situational crisis centers (SCC) of enterprises and regions.
Doza
Zelenograd
Produced in: Moscow
BR ASKRO "Penguin": A fast-deployable radiation monitoring system
BR ASKRO "Penguin": A fast-deployable radiation monitoring system
The fast-deployable radiation monitoring system (BR ASKRO) is intended for the operational creation of a local autonomous automated network of portable radiation monitoring posts in places where radiation emergencies occur. The main purpose of the system being created is continuous radiation monitoring, on areas up to 1 km2, when performing work to localize accidents and eliminate their consequences to ensure the safe operation of personnel of emergency rescue units, as well as to monitor the effectiveness of the work performed.
Doza
Zelenograd
Produced in: Moscow
SRK‑AT2327 ALARM METER
SRK‑AT2327 ALARM METER
Building a flexible and reliable multi-channel system Independent measurements on each channel in a wide range of gamma and neutron radiation dose rates and neutron and beta particle flux densities Audiable and light alarms High reliability and self-control Software that allows you to display on the PC monitor the current radiation situation in the controlled area Data logging Backup power supply The possibility of integration with external security systems
Produced in: Belarus, Minsk
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
Detection of gamma and neutron radiation sources in the flow of pedestrians crossing the border of the controlled object. Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software High reliability and self-control Backup power supply At the request of the user, the MCI can be supplied without a neutron channel.
Produced in: Belarus, Minsk
EMERGENCY DOSIMETRIC ALARM DRG‑AT2331
EMERGENCY DOSIMETRIC ALARM DRG‑AT2331
Detection of SCR in all possible range of its characteristics High reliability Self-monitoring of components Backup power supply Recording and storage of measurement results in the non-volatile memory of the device The possibility of integration with external security systems DRG-AT2331 together with SRK-AT2327, personal computer and software "SARK.NET " allows you to form an alarm system for detecting the occurrence of a self-sustaining chain reaction (SAS SCR).
Produced in: Belarus, Minsk
BR ASKRO "Penguin": A fast-deployable radiation monitoring system
BR ASKRO "Penguin": A fast-deployable radiation monitoring system
The fast-deployable radiation monitoring system (BR ASKRO) is intended for the operational creation of a local autonomous automated network of portable radiation monitoring posts in places where radiation emergencies occur. The main purpose of the system being created is continuous radiation monitoring, on areas up to 1 km2, when performing work to localize accidents and eliminate their consequences to ensure the safe operation of personnel of emergency rescue units, as well as to monitor the effectiveness of the work performed.
Doza
Zelenograd
Produced in: Moscow
PCUZ-1-1-BMD Gamma Radiation Level Detector
PCUZ-1-1-BMD Gamma Radiation Level Detector
The device gives out an electrical control signal when a gamma radiation flux with a gamma quantum energy of 1.25 MeV (200 FJ) is detected Parameters of the electrical control signal: - pulse duration of 0.1 – 0.6 sec.; - the amplitude of the pulse is equal to the value of the voltage of the on-board network. The time of setting the operating mode after the supply voltage is provided, is not more than 1 min The time of continuous operation of the alarm is at least 48 hours The signaling device is powered from the on-board DC voltage network. The power consumed by the alarm does not exceed 10 watts The alarm is resistant to impact of:  - high ambient temperature (+55°C) - low ambient temperature (-50°C) The alarm remains operational after exposure to:  - high ambient temperature (+70°C) - low ambient temperature (-65°C) The alarm is resistant to high humidity with a relative humidity of 100 % at a temperature of +35°C
Produced in: Kaluga region, Obninsk
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
Storage and transfer of kerma units in the air, ambient, individual and directional dose equivalents and their X-ray radiation capacities to working standards and measuring instruments. ▪ The use of highly stable ISOVOLT X-ray machines with metal-ceramic tubes ▪ Field shaper with radiation qualities according to GOST 8.087, ISO 4037, IEC 61267, etc. ▪ Replaceable discs with 11 filter slots; 3 replaceable diaphragms ▪ Additional filters up to 50 mm thick ▪ A protective flap made of tungsten with beam attenuation of more than 1000 times and a response time of less than 0.1 s ▪ A camera monitor and an electrometric unit provide monitoring of the presence and stability of the radiation output ▪ A positioning system in the radiation beam along three axes ▪ A laser detector centering devices ▪ A video surveillance system of indications ▪ Alarm and blocking systems, radiation monitoring ▪ A control system using operator panels and PC
Produced in: Belarus, Minsk
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
Transmission of units of absorbed dose, directed, individual dose equivalents and their beta radiation power as part of the working standard of absorbed dose (PD) and absorbed dose power (MPD) of beta radiation in a tissue equivalent substance. ▪ Use of closed radionuclide beta radiation sources 90Sr+90Y (BIS-50, 22 GBk), 85Kr (KAC.D3, 15 GBk) and 147Pm (BIP-50, 10 GBk) ▪ Formation of a reference field from sources by a mobile emitter unit using smoothing filters ▪ Source holders with shutter and protective screens ▪ Calibrated length rods and laser device for centering and digitizing ▪ A video surveillance system of readings ▪ The possibility of using an automated extrapolation chamber as part of the installation to reproduce the absorbed dose (absorbed dose rate) of beta radiation in the tissue ▪ Measurement of ionization currents from 1 fA when using an extrapolation chamber and a precision electrometer ▪ Software for installation operation, calibration and calculations ▪ An alarm and blocking system, control of photon radiation levels in the measurement room and operator room
Produced in: Belarus, Minsk
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT130
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT130
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT110
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk