Back to search results

PCUZ-1-1-BMD Gamma Radiation Level Detector

The device gives out an electrical control signal when a gamma radiation flux with a gamma quantum energy of 1.25 MeV (200 FJ) is detected

Parameters of the electrical control signal:

- pulse duration of 0.1 – 0.6 sec.;

- the amplitude of the pulse is equal to the value of the voltage of the on-board network.

The time of setting the operating mode after the supply voltage
is provided, is not more than 1 min
The time of continuous operation of the alarm is at least 48 hours
The signaling device is powered from the on-board DC voltage network.

The power consumed by the alarm
does not exceed 10 watts

The alarm is resistant to impact of: 

- high ambient temperature (+55°C)

- low ambient temperature (-50°C)


The alarm remains operational after exposure to: 

- high ambient temperature (+70°C)

- low ambient temperature (-65°C)


The alarm is resistant to high humidity with a relative humidity of 100 % at a temperature of
+35°C