Microparticle analyzer "SKAT-1"
Microparticle analyzer "SKAT-1"
1 supp.
Technical specifications: The time of one measurement is not more than 60 seconds Output of results to digital display board, RS485, RS232; current loop 4-20 mA, (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations of suspended particles is 0.02-5 SCAT-1(VC); 0.1-100 SCAT-1(n) mg/l Execution B4, P1, N1 according to GOST 12997-84 Category of climatic execution UHL4 according to GOST 15150-69 Relative humidity at +25 ° C is not more than 80% The error of photometry per channel is not more than 1% The size of the analyzed microparticles is 0.5-50 microns Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +50 °C Ambient temperature from +0.5 to +50 °C Atmospheric pressure 84-106.7 kPa The warranty period of operation is 1 year Average service life of at least 5 years Dimensions 300x400x150 mm Weight not more than 20 kg Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
1 supp.
Technical characteristics: The set-top box is powered by AC (220 ± 22) V, 50 Hz Power consumption, VA, no more than 35 Continuous operation time, h 8 Overall dimensions: (LxWxH), mm, no more than 320x290x160 The weight of the console, kg, not more than 6.5 Air consumption, dm3/min 2 ... 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-92"
Mercury analyzer "RA-915M" with the prefix "RP-92"
1 supp.
Technical specifications: Continuous operation time 8 hours Analyzer dimensions (LxWxH), mm, no more than 470x110x220 mm Overall dimensions of the pumping unit: (LxWxH), mm, no more than 360x110x125 mm Analyzer weight 7 kg The weight of the console is 7 kg Power supply 100 - 240 V Powered by an autonomous RA source-915+ - 6/14 In Powered by an autonomous source RP-91 - 12 V Power consumption 20 W Current frequency 50/60 Hz The mass of the pumping unit is 3 kg Average service life, years, at least 5 Volume of the injected sample, cm3 0.5 - 10.0 Air flow, dm3/min 0.8 - 4.2
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
1 supp.
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Biochemical analyzer (photometer) "BIALAB-100"
Biochemical analyzer (photometer) "BIALAB-100"
1 supp.
Technical specifications: Methods of analysis optical density, endpoint, kinetics, fixed time, nonlinear, two-wave, turbidimetry Light source halogen lamp (12 V, 20 W) with a slow start system to increase the service life Built-in interference light filters 340, 405, 505, 546, 578, 630nm; spectral half-width 12 nm The optical density measurement range is 0-2.5 E.O.P. The measurement error of optical transmission is not more than 1 % Memory of 100 measurement programs Temperature control of the measuring cell built-in thermostat with Peltier element: 25, 30, 37 ° C; accuracy ± 0.2 ° C Sample incubation thermostat external, for 16 vials The volume of the flow cell is 32 µl Consumption of the working reagent from 250 µl Built-in matrix printer, printing on plain paper with a tape width of 56 mm Liquid crystal display: 4 lines of 20 characters each Productivity of up to 100 analyses/hour by the endpoint method Dimensions and weight no more than 355x355x185 mm; 8.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
1 supp.
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
1 supp.
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg