CRYSTAL-2000 CHROMATOGRAPH
CRYSTAL-2000 CHROMATOGRAPH
Technical characteristics: DETECTOR - TYPE OF CHROMATOGRAPH - DETECTION LIMIT, G/S (G/ML) -STANDARD DEVIATION, % - LEVEL OF FLUCTUATIONAL NOISES, A (V) -DRIFT, А/H (V/H) FID Crystall-2000 5×10⁻¹² 2 2×10⁻¹⁴ 4×10 ⁻¹³ TCD Crystall-2000 (5×10⁻⁹) 2 (2×10⁻⁷) (2×10⁻⁵) ADC Crystall-2000 5×10⁻¹⁴ 4 1×10⁻¹² 8×10⁻¹¹ FPD-Р Crystall-2000 2×10⁻¹² 6 2×10⁻¹¹ 4×10⁻¹⁰ FPD-S Crystall-2000 2×10⁻¹¹ 10 2×10⁻¹¹ 4×10⁻¹⁰
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolyzer is designed to simulate the pyrolysis process and synthesis gas production technical specifications Reactor operating temperature range, 0C 20÷1100 Reactor inner diameter, mm 22 Reactor length, mm 1350 Thermocouple pocket availability Length of the isothermal zone, mm 700 The type of furnace is Casement Number of thermostatically controlled independent zones 1 The discreteness of the temperature setting, 0C 1 The flow range of the liquid pump, ml/min 0.0048÷36 Supply voltage 220V 50Hz Power consumption not more than 3.3 kW The discreteness of the temperatures and flow rates displayed on the displays is 0.1 Installation weight without cabinet, kg 100 Overall dimensions, mm 1400 x 400 x 1250 Weight, kg 60
Produced in: Yoshkar-Ola, Mari El
GAS PANEL
GAS PANEL
The gas distribution panel (hereinafter referred to as the panel) is designed to connect gas nodes and blocks of various analytical instruments, including chromatographs to shop gas lines. technical specifications Inlet pressure, not more than 0.8 MPa. The output pressure is from 0 to 0.4 MPa. Gas flow rate through each channel, not less than — 1000 cm3/min.
Produced in: Yoshkar-Ola, Mari El
COOLING LPG SV
COOLING LPG SV
Device for dosing of liquefied gases is made for insertion of liquids and liquefied gases under the pressure of 7 MPa into the chromatograph. Injection of liquefied gas without de-gassing is provided by cooling of valve, and it greatly reduces inaccuracy of the analysis results. Cooling temperature is set by temperature regulator. Visual control of absence of de-gassing and flow control of the analyzed fluid is provided. Dose volume is form 0.2 to 2 mcl. Valve of VICI production or dispenser valve of our own production is used directly as a sample-valve.
Produced in: Yoshkar-Ola, Mari El
CRYOSTATING DEVICES
CRYOSTATING DEVICES
The separation of some substances (the classic case is the separation of oxygen and argon) requires negative temperatures of the thermostat of chromatographic columns. technical specifications The lower temperature limit of the thermostat of columns with a cooling device based on an air conditioner is minus 5 °C. The error in maintaining the temperature of the thermostat of columns with a cooling device based on an air conditioner is + 0.05 °C. The power consumption of the cooling device based on an air conditioner, no more than — 640 VA. Overall dimensions of the cooling device based on the air conditioner, (width × depth × height), no more than — 620×480× 410 mm. The weight of the cooling device based on the air conditioner, no more than 32 kg. The lower limit of the temperature of the thermostat of columns with a liquid nitrogen cryoclap is minus 100 °C. The error of maintaining the temperature of the thermostat of columns with a liquid nitrogen cryoclave (in the temperature range less than 25 °C) + 0.1 °C. The power consumption of a cooling device with a liquid nitrogen cryoclave, no more than — 10 VA. Consumption of liquid nitrogen, not more than 0.1 l/h.
Produced in: Yoshkar-Ola, Mari El
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
META-CHROME AIR COMPRESSORS
META-CHROME AIR COMPRESSORS
The KOV-4 type air compressor is designed to supply flame detectors of gas chromatographs with air. Technical specifications: Capacity, at least, l/min 3 Outlet air pressure, 0.25+5 MPa% Pressure stability at constant flow rate, not more than 0.0007 MPa Engine power consumption, max, VA 100 Receiver volume, l 9 Noise level, no more, 60 dBa Weight, not more than, kg 19 Overall dimensions (width×depth×height), not more than, mm 235×755×440 Single-phase mains voltage 220 V, 50 Hz
Produced in: Yoshkar-Ola, Mari El
AUTOMATED INSTALLATION FOR DETERMINING THE WEAR OF THE CATALYST
AUTOMATED INSTALLATION FOR DETERMINING THE WEAR OF THE CATALYST
An automated installation for determining the wear of various catalysts, including KPS (FCC) for cracking with a fluidized bed by an air jet and is designed to determine the comparative wear characteristics of the KPS (FCC) of the catalyst by friction of an air jet according to ASTM D5757-11. It is used for testing with irregularly shaped spherical sludge particles (size from 10 to 180 microns). Abrasion is achieved by fluidization of the sample under the influence of jets of moist air. The percentage of fine particles (less than 20 microns in size) after a 5-hour test is an air jet abrasion index (AJI). technical specifications The range of operating air pressures for the power supply of the installation is 0.8±0.1 MPa The range of air flow rates for the power supply of the installation is not less than (l/min) 20 Absolute error of the air flow rate maintained automatically at a flow rate of 10 l/min. no more, l/min. ± 0.05 Power consumption not more than 0.2 kW Overall dimensions, mm and weight kg. 560x760x1700, 30 Abrasion pipe made of steel 12x18 n10t with dimensions, mm 710±10, 35 ± 0.5 Three sapphire nozzles with a diameter and length, mm 0.381±0.005, 2±1.0 Continuous operation mode Control: microprocessor with tactile control for setting the display and automatic maintenance of installation parameters and mathematical processing of analysis results 60 The convergence of the results when testing the same catalyst is not more than 0.1%
Produced in: Yoshkar-Ola, Mari El
LABORATORY HYDROTREATING-REFORMING UNIT
LABORATORY HYDROTREATING-REFORMING UNIT
The laboratory unit is designed to evaluate the activity of heterogeneous catalysts in a reactor with a fixed bed for the hydrotreating process. Ambient temperature from +10 to +35C; The relative humidity of the air is not more than 80% at a temperature of 25C;. Single-phase AC network with a voltage of 220 V ± 10% with a frequency of 50 Hz The average service life of the installation is 5 years. TECHNICAL CHARACTERISTICS OF THE HYDROTREATING AND HYDROGENATION UNIT Reactor: 1 piece Reactor volume, 240 ml Material 12X18H10T Inner diameter, mm 24 Length, mm 500 Operating temperature range, 0C 20÷600 Operating pressure range, MPa 0÷10 Removable pocket for thermocouples,mm 600 Reactor furnace: 1 piece Type of furnace Type of furnace Casement Number of thermostatic zones, pcs 3 The length of the full heated zone of the furnace, mm 450 The length of each of the four thermostatic zones, mm 150 The length of the isothermal zone of the furnace, mm 300 The power consumed by each isothermal zone, W 800 Power consumed by all three zones of the furnace, W 2400 The discreteness of the temperature setting, 0C 1 Hydrogen flow rate shaper: 1 piece Type of shaper, RGE Bronkhost Range of supported expenses, l/h 0-100 Inlet pressure, 100 bar Nitrogen flow rate shaper: 1 piece The type of the shaper, the leak (Nat2) Hy-Lok Range of supported expenses, l/h 0-10 Inlet pressure, 0-100 bar Raw material consumption shaper: 1 piece Shaper type, liquid pump KAPPA 10 Supported flow range, ml/min 0-10 Output pressure, 0-400 bar Raw material capacity: 1 piece Volume, l 4 Maximum pressure, atm 4 Working pressure, atm 0.2-1 Raw Materials Oil Installation: 1 piece Operating cycle of the installation, h 120 Inlet gas pressure calculated H2, N2, MPa 10 Actuation pressure of mechanical safety valves, 9.9 MPa Supply voltage 220V 50Hz The power consumption of the entire installation is not more than, kW 3 Installation weight without cabinet, kg 120 Overall dimensions, mm 1800x865x550 Overall dimensions of the cabinet, mm 2000x800x880
Produced in: Yoshkar-Ola, Mari El
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
SYRINGE FILLING DEVICE
SYRINGE FILLING DEVICE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), it is necessary to first fill a syringe with transformer oil with a carrier gas, and then, after achieving an equilibrium distribution of gases dissolved in oil between the liquid and gas phases, introduce the gas phase into the chromatograph (blow out the doses of the chromatograph dispenser tap). Moreover, the operations of filling the syringe and entering the sample are performed without air access. When filling the syringe, it is possible to fix the syringe stem at a certain volume. technical specifications The volume of syringes is 20 or 50 ml. The pressure at the outlet of the syringe filling line with argon is 0.5 atm. The range of ratios of volumes of the gas phase and oil (Vg/Vm) is from 0 to 1.5.
Produced in: Yoshkar-Ola, Mari El
CRYOCONCENTRATION DEVICES
CRYOCONCENTRATION DEVICES
To determine small concentrations of substances, in some cases it is impossible to do without their concentration in special traps. An example of the need for such concentration is the determination of impurities in permanent gases (Ne, He, H2, Ar, O2, N2, Kr, Xe), the concentration of impurities is less than 1 ppm. Considering that these impurities can be not only hydrocarbons, but also permanent gases themselves, the use of direct detection of impurities by a catarometer is impossible. It is also not always possible to use highly sensitive but expensive detectors (GID, EDD, etc.). TECHNICAL CHARACTERISTICS The volume of the trap is 5 ml. The volume of the Dewar vessel (serial metal thermos) is 1200 ml. The concentration temperature range is from minus 88.6 (ethane) to minus 269 °C (helium). The ability to calibrate the chromatograph from the cylinder without disturbing the gas circuit. The possibility, simultaneously with concentration, to purify the gas intended for purging the trap from impurities (in a similar trap). Overall dimensions, no more than — 290 ×470 × 615 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El