В настоящее время портал работает - ведутся технические работы.

Search

1187 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 22
    Areas of use
    Loading...
  • 161
    Item names
    Loading...
  • 24
    Manufacturer
    Loading...
  • Made in
  • 42
    Additional
    Loading...
View:
1187 products
Exhaust cabinet LAB-M SHV 180.74.210 TR
Exhaust cabinet LAB-M SHV 180.74.210 TR
Furniture for laboratory work. Exhaust cabinet made of chipboard Working surface: Trespa TopLab 6mm, on a substrate of wood-containing material (plywood 15mm, melamine 16mm). Overall dimensions: Length, mm: 1800 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - white chipboard with a thickness of 16mm guide posts – aluminum profile painted with powder paint dark gray (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-84V-S
Analytical scales VL-84V-S
from 192 490 ₽
Technical characteristics: NIP, G82 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 82g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range of the time of setting the readings, s, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-120C-O
Analytical scales VLA-120C-O
from 329 990 ₽
Technical specifications: NIP, g120 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of the permissible error of the scales during verification, ± mg, weighing intervals: from 0.01 g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, not more than 7 Adjusted weights 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory two-place shaker PE-6300 with heating
Laboratory two-place shaker PE-6300 with heating
from 111 312 ₽
Technical specifications: - The trajectory of the platform - orbital; - The amplitude of the platform movement - 24 mm; - Maximum stirring frequency - 200 rpm; - Deviation of the stirring frequency from the set one - ± 6, - Maximum adjustable platform heating temperature - +80°C; - Platform dimensions - 315x215 mm; - Platform capacity: flat-bottomed flasks 1000 ml - 2 pcs; flat-bottomed flasks 500 ml - 2 pcs; flat-bottomed flasks 100 ml - 4 pcs; - AC power supply (50 Hz) - 220 ± 10 V; - Overall dimensions - 350x300x155 mm; - Weight - 15.0 kg; - The maximum power consumption is 200 VA.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-120C
Analytical scales VL-120C
from 174 990 ₽
Technical characteristics: NIP, G120 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 3;- standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-6100
Laboratory scales VLTE-6100
from 47 990 ₽
Technical specifications: NIP, g6100 Discreteness, g0,1 External calibration The size of the bowl / platform of the scales, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 6100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-510S
Laboratory scales VLTE-510S
from 47 490 ₽
Technical characteristics: NIP, G510 Discreteness, g0,01 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.5 The price of the varification scale division, mg100 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 510g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Adjustment weight built-in Indication setting time, s, no more than~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-8201S
Laboratory scales VLE-8201S
from 154 990 ₽
Technical characteristics: NIP, G8200 Discreteness, g0,1 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5g to 5000g incl. ±500; sv. 5000g to 8200g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 300 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~0.7 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-3100
Laboratory scales VLTE-3100
from 67 490 ₽
Technical specifications: NIP, g3100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during primary verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 3100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~3 Weight adjustment 2kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-1100
Laboratory scales VLTE-1100
from 59 990 ₽
Technical specifications: NIP, g1100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 1100g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Adjustment weight 1kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-8100
Laboratory scales VLTE-8100
from 49 990 ₽
Technical characteristics: NIP, G8100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 8100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-6202S
Laboratory scales VLE-6202S
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 6200g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * up to 500g ± 30; sv. 500g ± 50 The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg