Search

1209 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 22
    Applying
    Loading...
  • 164
    Names
    Loading...
  • 24
    Manufacturer
    Loading...
  • Made in
  • 42
    Additional
    Loading...
View:
1209 products
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 87 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-411a
Circulation thermostat LT-411a
The LOIP LT-411a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 11 The working fluid is water, silicone oil. The open part of the bath / depth, mm 165x230/200 Overall dimensions, mm 268x335x400 Weight, kg 11.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg
DECO LABORATORY STOOL
DECO LABORATORY STOOL
from 9 950 ₽
Suitable for comfortable seating at tables from 750 to 900 mm high. It is possible to replace the standard gas lift with a high one, which will allow changing the height adjustment range of the chair from 570 to 820 mm and using such a stool to work at tables above 900 mm. The permissible load on the product should not exceed 120 kg. The seat diameter is 340 mm.
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Wall-mounted table LAB-1800 PCM
Wall-mounted table LAB-1800 PCM
equipment sink-drain (polypropylene, internal size 250*100*150mm), laboratory faucet for water the scope of delivery includes a siphon corrugated hose flexible liner length 1200mm rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel depth 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Media Converter SFP - SFP MCSFP2 - SFP
Media Converter SFP - SFP MCSFP2 - SFP
from 2 193 ₽
A media converter is used as a converter that converts one signal transmission medium into another. The data transmission medium means optical and copper cable. The scope of application – FastEthernet and GigabitEthernet protocols, STM-1 and STM-4. Media converters are characterized by a number of parameters, by setting that you can choose the optimal network equipment for solving a specific task. The possibility to control the device; Installation location; Properties of the optical receiver-transmitter; Supported transfer rate.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Spectrometer SPECTROSCAN MAX-GVM
Spectrometer SPECTROSCAN MAX-GVM
The spectrometer is designed to determine the contents of elements in the range from Na to U in substances in solid, powdery, dissolved states, as well as deposited on the surface or deposited on filters. The principle of operation of the X-ray spectrometer is based on irradiation of the sample with primary radiation from an X-ray tube, measurement of the intensity of secondary fluorescent radiation from the sample at wavelengths corresponding to the elements to be determined, and subsequent calculation of the mass fraction of these elements according to a pre-constructed calibration characteristic, which is the dependence of the content of the element to be determined on the measured intensity. Secondary fluorescent radiation is decomposed into a spectrum using a crystal analyzer. Due to this, the X-ray fluorescence spectrometer has a high resolution, and therefore the ability to accurately analyze complex multicomponent substances.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace LF-7/13-V1
Muffle furnace LF-7/13-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than mm 505x955x655 Rated supply voltage, 220 V Rated power, W 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet for muffle furnaces Mod. -1500 SHVMP
Exhaust cabinet for muffle furnaces Mod. -1500 SHVMP
from 131 472 ₽
The side, back walls and top are made of sheet metal. Automatic emergency power cut-off (16 A), two splash-proof sockets, a light-switch, an electrical box on the base panel's back. Flange to connect to exhaust system of ventilation (200 mm). The cabinat's base is a relocatable reinforced frame made of steel shaped tube on adjustable bearings. The exhaust box and the cabinet's base are painted with high-quality powder polymer paint, that protects the cabinet from the external effects of aggressive vapors, mechanical damage and high temperatures. Additionally, the cabinet can be equipped with a metal box for other supplementary equipment storage, consumables, tools.
Produced in: Saint Petersburg
Sliding cabinet LAB-400 TNYA-4
Sliding cabinet LAB-400 TNYA-4
Furniture for laboratory work. Sliding cabinet Length, mm: 400 Depth, mm: 580 Height, mm: 680 PACKAGE CONTENTS case – melamine 16mm thick inner size of the box – 310*470* 80mm roller supports h=60mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
High laboratory work table LAB-PRO SLv 150.65.90 TR-E16/23
High laboratory work table LAB-PRO SLv 150.65.90 TR-E16/23
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted low table LAB-PRO SPCn 90.80.75 KG-ESS
Wall-mounted low table LAB-PRO SPCn 90.80.75 KG-ESS
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Table top to table-cabinet LAB-PRO RP 90.80 SS
Table top to table-cabinet LAB-PRO RP 90.80 SS
Table top to the wall table on the support pedestal Material: STEEL (n/W steel with a side) Length, mm: 900 Depth, mm: 800
LOIP
Saint Petersburg
Produced in: Saint Petersburg