Search

475 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 176
    Names
    Loading...
  • 40
    Manufacturer
    Loading...
  • Made in
  • 44
    Additional
    Loading...
View:
475 products
High-frequency signal generator G4-229
High-frequency signal generator G4-229
The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range (RF output) from 9 kHz to 6 GHz Frequency range (LF outputs) from 0.001 Hz to 30 MHz Frequency tuning discreteness (RF output) 1 Hz Frequency tuning discreteness (LF outputs) 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main RF output is from minus 120 to 13 dBm The range of setting the signal amplitude at a load of 50 ohms (LF outputs) from 0.01 to 5 V The basic error of setting the reference power level (RF output) ± (0.5 – 1.0) dB The basic error of setting the amplitude of sinusoidal signals (LF outputs) ± (3 – 15)% Instability of the signal power level for any 15-minute time interval (RF output) no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the basic error of setting the frequency deviation ± (10 – 20)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient (when operating from an internal signal source) ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow
Filter holder FD-05D
Filter holder FD-05D
The filter holder FD-05D is designed to install aerosol and iodine filters in it, in an amount of up to 8 pieces. The filters are arranged sequentially. It is used in sampling systems of gas-aerosol media at radiation-hazardous and other production facilities.
Doza
Zelenograd
Produced in: Moscow
Heat exchanger TO-290/ TO-145
Heat exchanger TO-290/ TO-145
It is used in technological processes of nuclear, thermal and electric power plants, boiler houses and other facilities for cooling samples supplied to automatic and manual chemical control devices.Easy-to-clean collapsible structure. Materials with high mechanical properties are used: the coil is made of 316 SS steel, the body is made of 304 steel (or 12X18H10T). It is equipped with crimp fittings for connecting sample lines without welding. It is equipped with a special three-way ball valve for supplying / draining cooling water and a control valve that provides a change in the flow of cooling water through the heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
rhEpo
rhEpo
from 14 000 ₽
Erythropoietin (EPO) is a cytokine (glycoprotein) that stimulates erythropoiesis.
Produced in: Moscow
NV-400 TDYA Side cabinet (420*460*650)
NV-400 TDYA Side cabinet (420*460*650)
from 5 700 ₽
The NV-400 TDYA cabinet has a drawer and an insert shelf. The standard version of the side cabinet for the laboratory table includes: a niche, 1 drawer on roller guides, 1 swing door, 1 shelf insert, 2 mm shockproof PVC edge, 4 mm plastic baseplates. In the standard version, we offer side cabinets for laboratory tables in gray color. However, in agreement with the customer, it is possible to change the color to white, without increasing the cost. We are also ready to adapt the size and materials so that they meet your needs.
NV LAB
Moscow
Produced in: Moscow, Moscow region
rhGM-CSF
rhGM-CSF
from 17 000 ₽
Granulocyte-macrophage colony-stimulating factor is a hematopoietic growth factor and an immune response modulator. Human GM-CSF is a 127 amino acid monomeric protein with two glycosylation sites. The variability in glycosylation results in differences in molecular weight ranging from 14 kDa to 35 kDa. Non-glycosylated and glycosylated GM-CSF show similar activity in vitro.
Produced in: Moscow
MTP-01 Magnetic Coating Thickness Gauge
MTP-01 Magnetic Coating Thickness Gauge
from 75 000 ₽
Measuring range of thickness of protective coatings, mm: from 0.2 to 10 Digital display of measurement results: yes Power supply: from a PP3 type battery with a voltage of 9V Power consumption, MW: 100 Operating mode setting time, min: 1 Time of one measurement, sec: 3 Memory capacity, number of thickness values: 2000 Overall dimensions, mm: - electronic unit (width-depth length) 120x60x25 - measuring transducer (diameter height) 33x23 - connecting cable (length) 1500±300 Weight, g, no more: - electronic unit (without battery power) 80 - measuring converter 40 The kit includes: - Electronic unit, - Measuring converter - Plate made of non-magnetic material for setting the upper limit of measurements - Battery type PP3 - CD-ROM with the program - Prism - Cover - Spring - Case - Passport - Operation Manual
Produced in: Moscow
VD-12NFP Eddy Current Flaw Detector with 2 converters
VD-12NFP Eddy Current Flaw Detector with 2 converters
from 254 000 ₽
The device allows you to detect surface defects like cracks, visualizing the signal from the continuity interruptions on the display. The design of the flaw detector allows to determine with high reliability the exact location and depth of defects even on rough surfaces of flat and curved shape, including under a layer of corrosion or in the presence of a protective coating of the controlled area of the product with a thickness of up to 3 mm. The principle of operation of the VD-12NFP eddy current flaw detector: The principle of operation of the VD-12NFP eddy current flaw detector is based on the phenomenon of electromagnetic induction. An alternating magnetic field created in the primary coil of the converter by means of a sinusoidal voltage generator excites eddy currents in the controlled product. A parasitic magnetic field formed by eddy currents at the locations of defects affects the measuring unit (two signal coils connected in series) of the converter, creating an electromotive force in it. The amplitude and phase of the secondary signal carries information about the properties of the defect and the position of the transducer relative to the surface of the controlled product. The output signal from the measuring unit of the converter, after amplification and processing using a microprocessor, is displayed on the readout of the device, and is also stored in the memory block for subsequent transmission to a personal computer. In addition, information about the defects is displayed on a piezoelectric bell used as an audio indicator. Design, features and advantages of the VD-12NFP eddy current control device: The VD-12NFP eddy current flaw detector is a portable device capable of working both in a desktop and in a suspended position in a special bag-case. This ensures convenient operation of the device in a variety of conditions: in the laboratory, in the factory shop or during field tests. The flaw detector consists of an electronic unit with controls and display of test results, as well as three replaceable converters with wear-resistant corundum tips connected to the electronic unit using a connector. The choice of the desired converter depends on the magnetic properties of the material. For the control of parts with grooves, a converter with an inclined tip is offered. The device is powered by 4 AA batteries located in the battery compartment of the electronic unit. The advantages of the flaw detector include: - a screen for visualizing the signal during measurement; - light weight and compact dimensions that allow you to use the device in almost any conditions; - the ability to control the quality of products of various curvature and surface roughness even in the presence of a protective coating or a layer of corrosion; - wear resistance of converters, which is important when monitoring products with increased surface roughness (up to Rz£320); - automatic detection of the type of converter when connected, as well as the presence of built-in memory for storing control results; - the possibility to transfer data to a personal computer for storing or printing control protocols. Scope of application: Portability, high productivity, the ability to work with curved and rough surfaces, as well as the fact that the operation of the flaw detector is practically unaffected by humidity, pressure and contamination of the gas environment or the surface of the controlled product with non-conductive substances ensure the versatility of the device for detecting cracks in various materials. The eddy current flaw detector VD-12NFP is actively used in heavy industry for diagnostics of metal structures, assemblies and mechanisms for various purposes in factory workshops or laboratories, including at enterprises of railway transport, automotive industry, mechanical engineering, pipelines and metal structures. The VD-12NFP flaw detector can be used with equal success in the field, factory workshops, depots, laboratories and workshops to monitor the current condition, as well as to assess the degree of wear, the possibility and duration of further operation of such products made of metals and alloys as over-spring beams, wagon wheels, auto coupler housings, side frames, wheel couples and others. Distinctive features: • control of parts with surface roughness up to Rz320 due to wear-resistant corundum tips; • assessment of the degree of danger (depth) of the defect; • automatic detection of the converter type; • microprocessor control; • 5 universal programs for saving settings; • capable of detecting defects with a depth of 0.3 mm • The angle of deviation of the converter from the normal to the working surface up to 60° • Operating frequency of 70 kHz; • Maximum working clearance of 3mm; • visualization of the signal from the defect; • built-in memory for storing control results • Equipped with a Bluetooth 2.0 wireless communication module, which allows you to transmit control results and control the flaw detector at a distance of up to 20m; • The possibility of forming a control protocol based on the data transmitted to the PC; • Temperature range from 0°C to +40°C; • The design allows you to work with the flaw detector without removing it from the bag-case. Basic kit: Ia5.173.016: 1 electronic unit Ia5.125.031: 1 converter, type 1; marked as (•) Ia5.125.030: 1 converter, type 2; marked as (••) Ia2.706.002: the KOIDZ-VD set of samples with a passport (consisting of: Ia8.896.034: 1 piece; Ia8.896.035: 1 piece; Ia8.896.035-01: 1 piece) - A certificate of verification. 4 AA batteries 1 charger 1 small-sized phone 1 CD with software 1 special key 1 bag-case A calibration certificate is issued for the VD-12NFP flaw detector. 1 passport 1 operating manual 1 calibration instruction
Produced in: Moscow
NV-600 STP Mobile instrument table (600×350×650)
NV-600 STP Mobile instrument table (600×350×650)
from 10 773 ₽
This small mobile table is designed to move heavy equipment around the laboratory. When not in use, it can be moved under a regular office desk as the height of the NV-600 STP is 65 cm. The table top is made of laminated chipboard. The NV-600 STP has a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) and the lower shelf are edged on the facade with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The table wheels allow you to conveniently move the equipment around the laboratory. For easier movement, the table is equipped with side handles. In the drawer and on the bottom shelf, you can store equipment accessories or the necessary small stuff. Dimensions of the table when assembled (W×D×C): 600×350×650 mm. Advantages of NV-600 STP tables Small size: if it is not needed, it can easily be moved under a regular table. An inexpensive solution for laboratories that value the reliability and durability of furniture. Suitable for the small rooms. Application of NV-600 STP tables NV series tables are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Spectrum Analyzer SK4-105
Spectrum Analyzer SK4-105
The spectrum analyzer is capable of working both independently and as part of automated measuring systems with USB and ETHERNET interfaces. Technical specifications Frequency range from 9 kHz to 20 GHz The basic error of frequency measurement is ± (3-10'7hG + 0.2 Hz) Viewing bands 0; 10 Hz - 20 GHz Bandwidth minus 3 dB from 1 Hz to 8 MHz Self-noise level from minus 156 to 145 dB MW/Hz The basic level measurement error is ± (1.2-1.8) dB The relative level of interference caused by intermodulation distortions of the 3rd order from minus 50 to 65 dB The relative level of interference caused by combination distortions from minus 60 to 80 dB Amplitude scales linear, quadratic, logarithmic (0.1- 20) dB/div The frequency range of the tracking generator is from 1 MHz to 8 GHz Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 85 VA Overall dimensions, mm 420x213x172 Weight, not more than 8 kg
Produced in: Moscow