Search

487 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 183
    Names
    Loading...
  • 37
    Manufacturer
    Loading...
  • Made in
  • 45
    Additional
    Loading...
View:
487 products
rhTpo, human thrombopoietin, recombinant protein
rhTpo, human thrombopoietin, recombinant protein
from 18 500 ₽
Thrombopoietin is a glycoprotein hormone synthesized mainly in the liver, the main physiological regulator of platelet production. Participates in the development of precursors of other blood cells. TPO and other TPO receptor agonists are promising therapeutic agents.
Produced in: Moscow
UFO-3-20F UV Irradiator
UFO-3-20F UV Irradiator
from 49 000 ₽
The principle of operation of the device The principle of operation of the irradiator is based on the conversion of DC electrical energy into a normalized flow of ultraviolet radiation in the optical wavelength range of 350 ... 400 nm with a maximum at a wavelength of 365 nm. Design features and advantages The irradiator is a lantern consisting of an ultraviolet diode placed behind the focusing system, connected to a DC voltage converter, which supports the optimal mode of starting and functioning of the LED. Structurally, the irradiator is made in a lightweight duralumin housing, in the front of which there is a focusing system with an ultraviolet LED. The housing is equipped with a carrying strap. There is also a power on/off button on the case. As the power source of the irradiator, a lithium-ion battery of type 18650 with a nominal voltage of 3.7 V or 3 AA batteries with a voltage of 1.5V. are used. An ultraviolet LED is used as a source of ultraviolet (UV) radiation. The use of an LED distinguishes the UFO-3-20F irradiator from similar devices using UV lamps, it provides: high reliability and durability; variable diameter of the UV radiation zone; low current consumption and long continuous operation time; instant readiness for the first and subsequent turn-on; low weight, compact; high radiation intensity; stability of the characteristics of the irradiator, both during operation and throughout its entire life; wide operating temperature range. Scope of application The UV-3-20F irradiator (lantern) is used for ultraviolet irradiation of the surface of various parts, assemblies and mechanisms during flaw detection by fluorescent methods of non-destructive testing at machine-building enterprises, chemical and petrochemical industries, railway, automobile, water and aviation transport, during the laying and operation of pipelines, in construction, agriculture. The device can be used to check the quality of welds and internal surfaces of closed tanks. The luminescent method makes it possible to ensure high brightness and contrast of the indicator pattern, and, consequently, high sensitivity, especially on parts and products with a dark surface. Technical specifications The range of radiated wavelengths, nm 350...400 Ultraviolet irradiation at a distance of 300 mm, W/m2, not less than 20000 with a diameter of the irradiated area of 100 mm not less than 2000 Power supply from a lithium-ion battery type 18650 voltage of 3.7 V, or 3 AA batteries with a voltage of 1.5V Continuous operation time without recharging the battery, h, at least 4 Maximum irradiance at the wavelength, 365 nm Dimensions (diameter x length) 40 x 150 Weight (without batteries), kg, not more than 0.2
Produced in: Moscow
NV-1200 Ln Laboratory tables (1090×700×750)
NV-1200 Ln Laboratory tables (1090×700×750)
from 12 557 ₽
NV-1200 Ln are laboratory tables with a metal frame and a tabletop width of 1090 mm. They are designed for sitting work (the height of the table is 750 mm, this is the height of a regular office desk). The NV-1200 tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table assembled (W×D ×H): 1090×700×750 mm. The working surface for your tasks We offer laboratory tables with various working surface materials. Version: Countertop NV-1200 LLn: Laminate. A budget solution, suitable for school chemistry and physics classrooms, office work, placement of devices. NV-1200: LSPn. Chemically resistant plastic. A good choice for training workshops, analytical and medical laboratories. It does not tolerate high temperatures well, heating devices should not be placed on the surface. NV-1200 LKn: Porcelain tile. A practical solution for most chemical, biological, medical laboratories and workshops. You can put drying cabinets, baths and other heating devices on it. NV-1200 LNn: Stainless steel. Stainless steel is well suited for biological or medical laboratories, but it is not recommended for use in chemical laboratories. It has limited resistance to short-term exposure to concentrated mineral acids and alkalis and is destroyed by prolonged exposure to concentrated acids. NV-1200 LDl: Polypropylene. A specialized solution for chemical laboratories working with inorganic solvents. Advantages of NV-1200 Ln tables A budget solution for laboratories that value the reliability and durability of furniture; Suitable for small rooms; Heating plates or baths can be placed on the granite surface resistant to high temperatures; It is convenient to work while sitting: the height of the work surface from the floor is 75 cm, this is the height of an ordinary office desk. Application of tables NV-1200 Ln Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Specialized vacuum electric furnace VP-575-13
Specialized vacuum electric furnace VP-575-13
Specialized vacuum electric furnace for high-temperature soldering of large-sized products
VakETO
Mosrentgen
Produced in: Moscow
Droplet separator
Droplet separator
The drip collector is designed to remove droplet moisture when sampling air from indoor ventilation systems and is installed in gas aerosol sampling systems. Purpose: removal of droplet moisture from the selected air sample; accumulation of droplet moisture; indication of the level of accumulated moisture; draining the accumulated moisture.
Doza
Zelenograd
Produced in: Moscow
Pure nitrogen Generator GCHA-15-K
Pure nitrogen Generator GCHA-15-K
from 324 000 ₽
The characteristics of the device are similar to the GCHA-18-K model. The difference is the generator capacity of 15 liters /hour. An oil-free compressor is also built into the generator, which ensures complete autonomy of the device. The warranty for the device is 18 months, for the built–in compressor - 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) The maximum volume of nitrogen production is not less than 15 liters/hour (250 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than, min,* 45 Noise level generated by the compressor is no more than 45 dB Power consumption is not more than 200 VA Overall dimensions, (width x depth x height), not more than, mm, 230x470x510 Weight, not more than, kg 23 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life are at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Laser dosimeter LD-07
Laser dosimeter LD-07
from 125 000 ₽
LD-07 laser dosimeters are designed to measure the energy exposure and irradiance of scattered or reflected laser radiation in automatic mode, as well as to analyze the measurement results in accordance with current sanitary norms and regulations No. 580491, IEC 825-1-93 in order to determine the danger of radiation to the human body.
Produced in: Moscow
Pure nitrogen generator GCHA-60
Pure nitrogen generator GCHA-60
from 324 000 ₽
The pure nitrogen generator (hereinafter referred to as the generator) is designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments (chromatographs, including those equipped with an electronic capture detector, express analyzers of hydrogen content in metals, organic carbon concentration meters, sample evaporators, etc.). Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) * (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is not less than 60 l/hour (1.0 l/min) Nominal output pressure of nitrogen with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min. Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/hour, 1800 (30 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 220x540x670 Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
from 289 000 ₽
A set for measuring the levels of electrostatic and magnetic fields, the concentration of light negative and positive aeroions.
Produced in: Moscow