Search

472 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 173
    Names
    Loading...
  • 41
    Manufacturer
    Loading...
  • Made in
  • 47
    Additional
    Loading...
View:
472 products
AK-1000 Acoustic calibrator
AK-1000 Acoustic calibrator
characteristics The AK-1000 is recommended for use with OCTAVE-101A, OCTAVE-101AM, OCTAVE-110A, OCTAVE-110A-ECO, OCTAVE-121, OCTAPHONE-110, OCTAVE-201, ECOPHYSICS-110A sound meters. The AK-1000 can be used for calibration of acoustic measuring paths with VMK-205, MK-265, MR-201, M-201, MK-233 microphones, and other ½-inch microphones. technical specifications Reproducible ultrasound, dB (rel. 20 µPa): 94 and 114 The limits of the permissible basic error of the reproducible ultrasound, dB: ± 0.25 Limits of the permissible additional error of the ultrasound caused by a change in ambient temperature in the operating temperature range, dB: ± 0.08 Frequency of the reproduced sound pressure, Hz: 1000 Limits of the permissible basic relative error of reproduction of the sound pressure frequency, %: ± 0.7 Limits of the permissible additional relative error of the sound pressure frequency caused by a change in ambient temperature in the operating temperature range, %: ± 0.07 Coefficient of nonlinear distortion, %, not more than: 2.5 Weight (with batteries), kg, no more than: 0.250 Overall dimensions (length×diameter), mm, no more: 158×35 Operating conditions: - ambient temperature, ° C: from minus 10 to 50 - relative humidity (at 40 ° C), %, not more than: 90 - atmospheric pressure, kPa: from 65 to 108
Produced in: Moscow
NTEGRA NANO IR
NTEGRA NANO IR
NT-MDT Spectrum Instruments is an INTEGRA Nano IR–scattering scanning near‑field optical microscope (s-NSOM) designed for the infrared spectral range. The AFM probe is located in the focus of an optical system that directs the IR laser radiation to the sample and collects the optical response. The collected radiation is sent to the Michelson interferometer for optical analysis. The far-field component of the collected signal is suppressed by synchronous detection. The INTEGRA Nano IR system allows detecting the amplitude and phase of the near-field signal. The spatial resolution of the resulting reflection and absorption contrasts is approximately 10 nm and is determined only by the size of the tip of the probe.
Produced in: Moscow, Zelenograd
Alpha-beta radiometer for measuring small activities UMF-2000
Alpha-beta radiometer for measuring small activities UMF-2000
A low-background alpha-beta radiometer with a silicon detector, widely used for measuring small activities. It is recommended for measuring the total alpha and beta activity of natural and drinking waters, as well as for measuring the activity of alpha-emitting radionuclides by spectrometric method. Purpose: measurement of the total activity of alpha-emitting nuclides in "thick" and "thin" counting samples of environmental objects; measurement of the total activity of beta-emitting nuclides in counting samples of soil samples, water samples, air filters and samples obtained by selective radiochemical extraction; measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by radiometric method (if available); measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by the spectrometric method (if there are techniques and a set of spectrometric "UMF - Spectrum").
Doza
Zelenograd
Produced in: Moscow
Metolab 451 Vickers Hardness Tester
Metolab 451 Vickers Hardness Tester
METOLAB 451 is a stationary hardness tester for measuring various materials using the Vickers method (HV scale) in full compliance with GOST R ISO 6507-1-2007. Due to its characteristics, the device allows you to measure the hardness of steels, cast iron, non-ferrous metals, soft alloys and other similar materials. The hardness tester is equipped with an electronic load value switch, has the functionality of entering diagonal length values from the control panel with subsequent automatic calculation of hardness. It is also possible to note a wide range of measured values (from 5 to 2500 HV) and the range of the applied load (from 1 to 50 kg). The automatic METOLAB 451 Vickers hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) and comes with a certificate of primary verification (on request). The entry number in the GRSI is 67656-17. Distinctive features of the stationary METOLAB 451 Vickers hardness tester: Simple and intuitive control of the device; Simplicity and ease of maintenance of the hardness tester; Wide range of measured values – from 5 to 2500 HV; Automatic application of test loads in the range: 1 kg (9.8 N); 2 kg (19.61 N); 3 kg (29.4 N), 5 kg (49 N), 10 kg (98 N); 20 kg (196.1 N); 30 kg (294 N), 50 kg (490 N); The price of dividing the scale of the reference microscope: 0.5 microns at 200x, 1 microns at 100x; The hardness tester is equipped with an electronic load value switch; A bright and clear LCD display that displays all the necessary service information, including the selected scale, the set load, exposure time, test mode, etc.; An automatic loading system guarantees high accuracy and repeatability of the results. Basic delivery package: Stationary METOLAB 451 hardness tester; Standard Vickers hardness test - 2 pcs.; Flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle at the top of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
Vacuum electric furnace for quenching in oil D-10.30.E-14UU-M
Vacuum electric furnace for quenching in oil D-10.30.E-14UU-M
The system of internal quenching of long hollow parts. Mixing systems of the inner and outer parts of the quenching tank. Closing the intermediate vacuum gate until the start of quenching (allows to keep a clean heating chamber).
VakETO
Mosrentgen
Produced in: Moscow
Dosimeter-radiometer ISS-17D "Finch"
Dosimeter-radiometer ISS-17D "Finch"
Purpose: measurement of the power of ambient dose equivalent (MAED) and ambient dose equivalent (ED) of photon radiation; operational search for sources of ionizing radiation and radioactive materials; measurement of the flux density and fluence of alpha and beta radiation; measurement of surface alpha and beta activity; measurement of the ambient dose equivalent (MAED) power of neutron radiation.
Doza
Zelenograd
Produced in: Moscow
NV-1200 PC-M Physical wall-mounted laboratory table
NV-1200 PC-M Physical wall-mounted laboratory table
from 17 884 ₽
NV-1200 PC-M is an inexpensive table with a superstructure in the NV line. The countertop with a depth of 70 cm is made of granite tiles. It is designed for standing work: the height of the table top is 85 cm. External dimensions of the table (W×D×H): 1218×700×1650 mm. A minimalistic solution for your laboratory The table top is made of granite tiles. The tile is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. It has limited resistance to hydrofluoric acid. This is one of the most popular types of countertop materials for laboratory furniture. The superstructure allows you to compactly place the necessary reagents and laboratory utensils next to the workplace. Its depth is 25 cm, and its height is 80 cm. The side laminated panels (chipboard 16 mm thick) are edged with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Advantages of NV-1200 PC-M tables An inexpensive solution for laboratories that value the reliability and durability of furniture; Suitable for small rooms; Heating plates or baths can be placed on the granite surface, it is resistant to high temperatures; It is convenient to work while standing: the height of the working surface is 85 cm. On the shelves you can store accessories for devices on the table, laboratory utensils or reagents. Application of NV-1200 PC-M tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
NV-800 MOP Wash table with dryer (800×600×1650)
NV-800 MOP Wash table with dryer (800×600×1650)
from 22 117 ₽
The NV-800 MOP is a table with a deep sink made of polypropylene and with a plastic dryer for 18 dishes. It is designed for standing work: the height of the countertop is 85 cm. Dimensions when assembled (W×D×H): 800×600×1650 mm. The table top is made of laminated chipboard. It has a built-in Stegler WJH0357F polypropylene sink, its internal dimensions (W×L×H): 490×390×290 mm. The polypropylene is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents and is excellent for washing laboratory dishes. The side laminated panels of the table (chipboard 16 mm thick) are edged on the facade with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The package includes a stainless steel mixer with flexible 300 mm tap connectors and a siphon. The upper part of the inclined shelves of the dryer on which dishes are placed, is covered with a polypropylene insert to protect against water and reagents. The pins are also made of polypropylene. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Advantages of NV-800 MOSFET tables A minimalistic compact model with polypropylene sink and dryer. An inexpensive solution for laboratories that value the reliability and durability of furniture. Due to its size, it is suitable for very small rooms. Application of NV-800 MOP tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Highly coherent tunable diode lasers with an external resonator
Highly coherent tunable diode lasers with an external resonator
Highly coherent tunable diode lasers with an external resonator are used in projects related to the development of optical frequency standards (on ytterbium and thorium ions), in studies of degenerate gases, Rydberg atoms.
FIAN
Moscow
Produced in: Moscow
NV-1210 LCn Laboratory table (1210×610×750)
NV-1210 LCn Laboratory table (1210×610×750)
from 16 121 ₽
The NV-1210 LCn is a laboratory table with a metal frame and a table top made of monolithic ceramics. Table top width: 1210 mm. The table is designed for sitting work, its height is 750 mm (this is the height of a regular office desk). The table top made of monolithic ceramics is moisture-resistant, perfectly withstands high temperatures. As there are no seams, ceramic granite tiles are better resistant to chemicals and heat. It is possible to place high-temperature equipment on it. NV-1210 tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table assembled (W×D×H): 1210×700×750 mm. Advantages of NV-1210 LCn tables An inexpensive solution for laboratories that value the reliability and durability of furniture; Suitable for small rooms; Heating plates or baths can be placed on the porcelain stoneware surface resistant to high temperatures; It is convenient to work sitting down: the height of the work surface from the floor is 75 cm. Application of NV-1210 LCn tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Filter holder FD-05D
Filter holder FD-05D
The filter holder FD-05D is designed to install aerosol and iodine filters in it, in an amount of up to 8 pieces. The filters are arranged sequentially. It is used in sampling systems of gas-aerosol media at radiation-hazardous and other production facilities.
Doza
Zelenograd
Produced in: Moscow