Search

69 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 7
    Applying
  • 30
    Names
    Loading...
  • 1
    Manufacturer
  • Made in
  • 12
    Additional
View:
69 products
HYDROGEN GENERATORS (75 L)
HYDROGEN GENERATORS (75 L)
These generators are designed to supply hydrogen to flame chromatographic detectors. The produced hydrogen meets the requirements of GOST 3022-80. Technical specifications for GV-75 iGV-75-O: Productivity H2, l/h 0-75 0-75 O2 capacity, l/h - 37 Maximum output pressure, atm 2 2 Hydrogen pressure stability, not worse, atm 0.0025 0.0025 Hydrogen water content, not more than, ppm 5 5 Purity of hydrogen, % 99.995 99.995 Time to enter the mode, min 30 30 Water consumption, g/l H2 1.0 1.0 Working time without refilling water, hour 4 4 Tank volume O2, l 2.5 2.5 The volume of water to be added to the O2 tank when the "Top up water" alarm is triggered is no more than 1,4 1,4 liters Power consumption, max, VA 800 800 Overall dimensions (width×depth×height), not more than, mm 260×438×550 260×438×550 Weight, not more than, kg 25 26
Produced in: Yoshkar-Ola, Mari El
REVERSE PURGE VALVE
REVERSE PURGE VALVE
The reverse purge valve is a 4-way valve designed to change the direction of the flow of the eluent through the nozzle column and blow off heavy components from the beginning of the column in the opposite direction into the detector. The crane is attached to the bottom panel (bottom) of the module, while taking the temperature of the column thermostat. The two upper fittings (see Fig.) are used to connect the column, the other two are connected to the evaporator and the detector.
Produced in: Yoshkar-Ola, Mari El
LIQUEFIED GAS METERING VALVE
LIQUEFIED GAS METERING VALVE
The metering valve for the analysis of liquefied gas (KDSG) is designed for the introduction of liquefied gas or other liquid under excessive pressure into the evaporator of the chromatograph. KDSG is a 4-way crane, in which a dose of a certain volume is installed. The tap is installed on the evaporator of the chromatograph. A dose of any volume can be installed on the tap. Dose change can be performed by the operator. The amount of the dose volume is indicated on the tag. Technical specifications The dose volume is from 0.25 to 4.0 µl (at the request of the consumer, the dose volume can be increased up to 10 µl). The tap temperature is no more than 150 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle is 90 °C.
Produced in: Yoshkar-Ola, Mari El
AUTOMATIC DIGITAL MULTI-CHANNEL PRESSURE MAINTENANCE SYSTEM IN THE VACUUM CHAMBER
AUTOMATIC DIGITAL MULTI-CHANNEL PRESSURE MAINTENANCE SYSTEM IN THE VACUUM CHAMBER
The system includes a digital ionization-thermocouple vacuum meter with a continuous pressure measurement range, automatic degassing of sensors and a digital gas flow meter containing two or more built-in precision gas flow regulators, with thermometric gas flow meters, which allows the device to operate in the mode of autonomous intake of specified gas flow rates, regardless of the inlet pressure. The letters in the diagram show: А — electronic unit of vacuum gauge B — 220V power wire С — thermocouple lamp D — ionization lamp E — the electronic control unit of the leak valve G — signal cables H — cable for data exchange with IBM J — IBM L — cable for data exchange between the units M — cable for connecting additional devices to the network N,O — working gases inlet P,R — output of the working gases.
Produced in: Yoshkar-Ola, Mari El
High pressure gas flow regulator RRG-VD
High pressure gas flow regulator RRG-VD
It can be used as a primary source of carrier gas, since it is equipped with an additional gas purification system. This device is especially relevant when, for some reason, helium is not available to the consumer (for example, when working with a thermal conductivity detector - an accident). Due to the high thermal conductivity of hydrogen, TTP operates with significantly greater sensitivity than helium.
Produced in: Yoshkar-Ola, Mari El
DIGITAL MULTICHANNEL LEAK
DIGITAL MULTICHANNEL LEAK
The Meta-chrome digital gas flow meter is designed to maintain a given pressure and the ratio of the amount of gases (in the flow mode) or gas flow (in the intake mode) in vacuum installations with automatic and manual control. technical specifications The number of control channels is 2 (or more on request). The maximum flow rate for each of the channels is 700 cm3/min. The possibility of using gas correction coefficients, the most commonly used gases are listed in the leaker database. The accuracy of maintaining a given proportion of gases is 5%. The accuracy of maintaining the specified gas flow rates is 3%. Input pressures from 1 to 4 atm. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption (without a personal computer), no more than — 30 VA. Overall dimensions (width × depth × height), no more than 165×350×215 mm. Weight, not more than 5.5 kg.
Produced in: Yoshkar-Ola, Mari El
Gas chromatograph Crystallux-4000m
Gas chromatograph Crystallux-4000m
The gas chromatograph "Kristallux-4000M" is fully automated, starting from sample input and ending with chromatographic information processing, including the functions of automatic temperature control of thermostats, flow rates and pressure of the carrier gas (EUPG system), auxiliary gases, automatic ignition of detectors, flame burning control during operation, measurement of detector signals using Gorenje 24-bit ADC. Technical specifications: The detection limit of PID is 1,1x10-12 gS/s for h-hydrocarbons 1,1x10-12 gS/s for propane. The detection limit of DTP1.7x10-14 g/s for lindane 3.9x10`15 g/s for lindane (micro-ED) The detection limit of EZD1x10`13 grus for phosphorus in metaphos 8x10`13 g5/s for sulfur in metaphos or hydrogen sulfide PFD detection limit 1.5x10`14 g/s for phosphorus in metaphos 3x10`13 GM/s for nitrogen in azobenzene Detection limit of TID2x10`10 g/ml by hydrogen The detection limit of TcD is 5x10`13 g/s for benzene The detection limit of the FEED is 3x10`13 g/s for carbon in methane 3x10`13 g/s for carbon in methane Detection limit GID500:1 (M7-801) with the introduction of 1x10`12 g / ml of octafluoroaphthalene The signal-to-noise ratio of MSD 1500:1 (Maestro-oMS) when entering 1x10`12 g / ml of octafluoroaphthalene Linear dynamic range of PID x1*107 Linear dynamic range DTP1*108 The volume of the column thermostat is 14 (19)l The temperature of the column Current.Wednesday +3 °C to +400 °C (by special order up to 450 °C) (by special order from -10°C with use. cold. ust-ki)(by special order from -100 °C. with use. liquid, no.) The discreteness of the temperature setting is 0, ° C Temperature stability 0.01 °C Temperature programming speed 0t 0.1 to 125 °C/min (by special order up to 150 °C/min) The number of isotherms is not less than 30 The cooling rate of the column thermostat is from 400 to 50 °C3.3 min. The maximum temperature of the detector and evaporator is 450 °C Carrier gas consumption from 0 to 100 ml/min.(by special order up to 500 ml/min.) Carrier gas pressure (for capillary column) from 0 to 0.40 Mpa (by special order up to 1 MPa) The maximum inlet gas pressure on a special order is 0.5 MPA 1.25 MPA Hydrogen consumption 0-500 Air consumption 0-1000 Overall dimensions (width x depth x height) 550%500*500 mm Weight 39 kg Electric power supply from AC mains voltage (220.2) V, frequency (50 +1) Hz The maximum power consumption (in steady-state mode) is 900 VA.
Produced in: Yoshkar-Ola, Mari El
HIGH PRESSURE SYRINGE PUMP
HIGH PRESSURE SYRINGE PUMP
High-pressure syringe pump (NSHVD-1) with a continuous highly stable fluid flow in a wide flow range of 0.01-10ml/min. with the functions of introducing a correction factor after calibration, setting the volume or pumping time, displaying the amount of pumped, temporary suspension of pumping with automatic resumption, the ability to adjust the flow and volume of the pumped liquid during operation without stops, automatic shut-off of the pump when the set maximum pressure is exceeded, remote control, compensation for changes in the mass flow rate of the liquid pumped by the pump when its temperature changes. TECHNICAL CHARACTERISTICS Flow range, ml/min 0.01 - 10 Dosing error, % 0.2 The discreteness of the task, % 0.01 Maximum working pressure, 12 bar Lifting height of the suction fluid, m2 Accuracy of pressure measurement, % 0.2 The maximum liquid temperature is 60 °C Modbus RTU communication interface Power supply AC 220 V, 50 Hz Dimensions: W x D x H, mm 140 x 335 x 270 Materials in contact with the pumped liquid glass, fluoroplast, stainless steel 316 L
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolytic gas chromatography method is widely used in the study of polymer materials, plastics, rubbers, rubbers, paints and other high-molecular compounds of natural and artificial origin. The method is based on thermal decomposition of sample samples in an inert medium (without oxygen access), followed by chromatographic separation and analysis of the formed volatile compounds. Thus, the resulting pyrogram allows us to judge the composition of the original sample. Pyrolysis is also used in geochemical studies. Technical specifications The volume of the capsule is 56 ml. Pyrolysis temperature — from 200 to 1000 °C. The error of maintaining the temperature is not more than 1.0 ° C. The heating time of the sample to the pyrolysis temperature is no more than 2 seconds. The cooling time of the capsule when moving from the hot zone to the cold zone after pyrolysis is no more than 10 seconds. The time of continuous operation in the pyrolysis mode is no more than 60 seconds. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Power consumption — no more than 100 VA. Overall dimensions of the control unit (width ×depth×height) — 210×190×100 mm. Overall dimensions of the input node (width× depth×height) — 90×135×160 mm. The weight of the control unit is not more than 2.5 kg. The weight of the input node is not more than 0.9 kg.
Produced in: Yoshkar-Ola, Mari El
DISPENSER "EVEN 4000"
DISPENSER "EVEN 4000"
The dispenser "DAZH 4000" is designed for automatic insertion of liquid samples into the evaporator of the gas chromatograph, provides: control from the software, setting variable parameters of algorithms for washing and sample entry, storing the operating parameters of the dispenser in the method. Technical characteristics: The number of vials in the carousel, pcs up to 30 The volume of installed vials, ml 0.1-2ml Number of injections from one vial 1-99 Replaceable syringes in volume, ml 10, 100, 250, 500 The volume of the injected sample, ml : from 0.01 to 500 The discreteness of setting the sample volume, µl: from 0.01 to 1 Sampling and insertion rate, µl/s: from 0.01 to 5000 The speed of needle insertion into the evaporator, discret 3 Immersion depth in the vial and evaporator, variable up to the length of the syringe needle, mm 1 – 99 The discreteness of the dive depth setting, mm 0,1 The number of pumping during sampling 0-15 Number of solvent washes 0-15 Needle exposure time in the evaporator, sec 0-99 The discreteness of setting the needle shutter speed, sec 1,0 Sample input modes Simple insertion, Sandwich, Solvent sandwich, Sandwich with internal standard Flushing mode From the vial Supply voltage, V (frequency, Hz) 220 (50) Power consumption, W 154 Weight, kg, no more 2,9 Overall dimensions, mm 175x270x420 Communication with the computer Ethernet
Produced in: Yoshkar-Ola, Mari El
Thermionic (TID)
Thermionic (TID)
Selective detector for organophosphorus and nitrogen compounds. It is also sensitive to compounds containing C, Az, but to a lesser extent. The sensitivity depends on the number of heteroatoms in the molecule. Selectivity to hydrocarbons is 104 for nitrogen, and 105 for phosphorus Technical characteristic: 2.0*10-13 m/s nitrogen 1.5*10`14 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
Designed to control the pressure and flow rate of non-aggressive gases in the lines of chromatographic and other analytical equipment. The measurement of gas flow is based on the conversion of the mass flow rate of gas into an electrical signal by the calorimetric method. The measured gas flow and pressure are displayed on a digital indicator. The device has an external RS485 interface, operating under the MODBUS RTU protocol. technical specifications: - gas flow measurement range – from 1 to 750 ml/min; - pressure measurement range from 0 to 0.4 MPa; - gas flow measurement error – no more than ± 2% in the measurement range of 100 art. ml / min; no more than 3% in the measurement range of 100 ... 750 art. ml / min; - measurement error suppression – no more than ± 0.25 %; - measured gases: Air, Nitrogen, Hydrogen, Helium, Argon, Methane; - the presence of a function for monitoring the volume of pumped gas for a given period of time; - the presence of a function for monitoring changes in gas pressure for a given period of time;- the device is powered from an external power source + 15V (an adapter for operation from a 220V 50Hz network is included in the delivery package).
Produced in: Yoshkar-Ola, Mari El