Search

156 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 1
    Applying
  • 10
    Names
  • 1
    Manufacturer
  • Made in
  • 1
    Additional
View:
156 products
3VVN1-3M(N) Water ring vacuum pump
3VVN1-3M(N) Water ring vacuum pump
The 3VVN1-3M(N) water ring vacuum pump with a capacity of 3.5 m3/min at an initial pressure of 0.04 MPa is designed for general industrial use, to create and maintain a vacuum in the operating pressure range from atmospheric to 10 kPa. The working fluid of the pump is water. The use of the 3VVN1-3M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working organs. The 3VVN1-3M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-3M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
ND-500 High-vacuum diffusion pump
ND-500 High-vacuum diffusion pump
The working condition of the ND-500 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-500 diffusion pump is a maximum of 5.5 liters, a minimum of 4 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change.The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of the heaters in the ND-500 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-500 diffusion pump up to 320°C, the temperature sensor should give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be carried out only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4 ° C to plus 25 ° C. The recommended cooling water consumption for the housing is 500 l/h, for the oil reflector it is 50 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break). The required speed of action of pre-vacuum pumps at a pressure of 26 Pa (0.2 mm Hg.st) in the outlet section of the ND-500 diffusion pump should be at least 42 l/s. To reduce the losses of the working fluid of the ND-500 diffusion pump at pressures (1·10-1- 1) Pa [(7,5·10-4- 7,5·10-3) mmHg] it is recommended to install an additional LP-500 flow-through water trap on the outlet flange.
Produced in: Kazan
ZVPlE-500 Flat Electric Vacuum Shutter
ZVPlE-500 Flat Electric Vacuum Shutter
The ZVPlE-500 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-500 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and regulate the shutter. ZVPlE-500 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan
MU-630 Enlarged oil reflector
MU-630 Enlarged oil reflector
The MU-800 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens to capture oil return flow vapors.
Produced in: Kazan
2ZVE-160 Electromechanical Vacuum shutter
2ZVE-160 Electromechanical Vacuum shutter
The 2ZVE-160 vacuum shutter with electromechanical drive equipped with 160mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75x10–8 to 800 mm Hg). The 2ZVE-160 shutter is pendulum-type. The 23VE-160 shutter is manufactured in the climatic version UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air and non–aggressive gases. It is not intended for use in fire and explosive hazardous industries. The 23VE-160 shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
AVD-50/5 Two-rotor vacuum unit
AVD-50/5 Two-rotor vacuum unit
The AVD-50/5 unit consists of a NVD-200 series-connected two-rotor vacuum pump and a 2NVR-5DM plate-rotor vacuum pump. 2NVR-5DM and NVD-200 pumps are installed on the lower and upper base of the frame and secured with bolts, nuts and washers. The pumps are connected to each other by means of a pipeline and a bellows assembly. By installing the rings during assembly of the unit, the size of the bellows assembly is set. The AVD-50/5 unit can operate continuously at an inlet pressure of no more than 133 Pa (1 mm Hg) or pumping out one or more sealed vessels with a total volume of 3.5 m3 from atmospheric to maximum residual pressure for 8 hours.
Produced in: Kazan
3VVN1-25 Water ring vacuum pump
3VVN1-25 Water ring vacuum pump
The 3VVN1-25(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-25(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006
Produced in: Kazan
MU-1000 Enlarged oil reflector
MU-1000 Enlarged oil reflector
The MU-1000 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens for capturing oil return flow vapors.
Produced in: Kazan
ABB-50 Water Ring Vacuum Unit
ABB-50 Water Ring Vacuum Unit
The AVB-50 vacuum water ring unit consists of a 3BBH2-50 vacuum water ring pump and an EV-50 water ring vacuum ejector
Produced in: Kazan