Search

149 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 19
    Applying
    Loading...
  • 59
    Names
    Loading...
  • 7
    Manufacturer
  • Made in
  • 24
    Additional
    Loading...
View:
149 products
RADIATION PEDESTRIAN MONITOR MPP‑AT930
RADIATION PEDESTRIAN MONITOR MPP‑AT930
▪ Rapid adaptation to changes in the radiation background ▪ Audible and light alarms when gamma radiation is detected ▪ Mobility and the possibility of forming passages ▪ Self-control of components in the process of work ▪ The possibility of continuous or episodic radiation monitoring ▪ The possibility to work from a 230V, 50Hz network or from a built-in rechargeable battery Compliance with the international standard IEC 62244:2006 Stationary radiation monitors for the detection of radioactive and special nuclear materials at state borders
Produced in: Belarus, Minsk
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
Detection of gamma and neutron radiation sources in the flow of pedestrians crossing the border of the controlled object. Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software High reliability and self-control Backup power supply At the request of the user, the MCI can be supplied without a neutron channel.
Produced in: Belarus, Minsk
Water distiller AWD-7000F
Water distiller AWD-7000F
Distillers of the company "BELAKVILON" are designed to produce distilled water from tap water. Capacity 6.5 — 7 l/h Dimensions (mm), W x D x H 510 x 465 x 490 Heater 2 x 3.0 kW Cooling water consumption, l/h about 30 — 50 l/h Power supply 230 V ±10%, 50 Hz Switch Differential automatic Water level sensors Reed floats
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
Measurement of the power of the ambient dose equivalent and the ambient dose equivalent of neutron radiation, as well as simultaneous monitoring of the power of the ambient dose equivalent and the ambient dose equivalent of gamma radiation. A wide energy range Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4 Audible and visual alarm of exceeding threshold levels
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
High sensitivity Sound, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions A wide range of measurements
Produced in: Belarus, Minsk
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Water bath WB-8
Water bath WB-8
WB series baths can be used for sample evaporation, incubation, defrosting, conduction of chemical reactions. Temperature setting range, oС +35…+95 Temperature error, oС ±1.0 is protected from excess temperature RAINBOW TSR-150S F-C Hydraulic thermostat Supply voltage, V 230+-10% Current consumption 6.5A Power consumption, 1500 W Overall dimensions L x W x H, mm 550 x 300 x 190 Overall dimensions of the bath L x W x H, mm 460 x 300 x 140 Total / engine capacity, 19.1/14.3 l
Produced in: Belarus, Minsk
 INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
Control of individual radiation doses from X-ray and gamma radiation. Together with the reader and software, they form an effective system for automated control of dose loads on personnel. ▪ Simultaneous measurement of the power of the individual dose equivalent and the dose of gamma radiation ▪ Automatic compensation of the detector's own background ▪ The mode of signaling the presence of pulsed radiation with a duration of 10 ns (optional)
Produced in: Belarus, Minsk
Generator G6-46
Generator G6-46
Technical specifications: Frequency range, from 0.1 Hz to 1 Frequency range, from 0.1 Hz to 1 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span)Smooth signal attenuation, at least 20 dB Frequency stability in 15 minutes, no more than 0.5% Hz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span) Smooth signal attenuation, at least 20 dB Frequency instability in 15 minutes, no more than 0.5 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeters V7-65, V7-65/1, V7-65/2
Voltmeters V7-65, V7-65/1, V7-65/2
Technical specifications: Measuring range 20 mv-1000 V Measurement error ± (0.03% +5 E.M.R.) AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.3% +200 E.M.R. - 4% +800 E.M.R.) Frequency range 20 Hz-100 kHz Direct current Measuring range 1 mA - 2 A Measurement error ± (0.12% +10 E.M.R.) Alternating current Measuring range 10 mA - 2 A Measurement error ± (0.6% +300 E.M.R.) Frequency range 20 Hz - 5 kHz
MNIPI
Minsk
Produced in: Belarus, Minsk