Universal calibrator H4-301/1
Universal calibrator H4-301/1
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (UK) 200 MV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range Uk 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, sv. 20 to 40 kHz 0.2 + 0.1 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 2; 20 V 0.15 + 0.02 Basic error, ± (% of U + % of Uk): from 20 Hz to 20 kHz 0.15 + 0.02 Uk 200 V; 600 V: 0.2 + 0.05 from 40 Hz to 1 kHz 0.2 + 0.05 DC power reproduction range: from 1 Ma to 200 mA, sub-bands (Ic) 200 Ma; 2; 20; 200 mA Ic 200 Ma 0.1 + 0.02 Basic error, ± (% of I + % of Ic): Ic 2; 20; 200mA 0.1 + 0.01 Power reproduction range AC: from 10 Ma to 200 mA, sub-ranges (Ic) 200 Ma; 2; 20; 200 mA 0.15 + 0.05 Frequency range from 20 Hz to 1 k Hz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 to +50 C Dimensions; weight 428×327×235× mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
 INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
Control of individual radiation doses from X-ray and gamma radiation. Together with the reader and software, they form an effective system for automated control of dose loads on personnel. ▪ Simultaneous measurement of the power of the individual dose equivalent and the dose of gamma radiation ▪ Automatic compensation of the detector's own background ▪ The mode of signaling the presence of pulsed radiation with a duration of 10 ns (optional)
Produced in: Belarus, Minsk
SPECTROMETRIC RADIATION MONITORING SYSTEM
SPECTROMETRIC RADIATION MONITORING SYSTEM
Displaying the spectra and dose rates measured by each detection unit (DB) on the object plan or terrain map Identification of the radionuclide composition of the source The possibility of expanding the energy range up to 5 MeV Sealed DB design (IP68) Backup power supply
Produced in: Belarus, Minsk
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
Rapid assessment of surface contamination with alpha-active radionuclides, in particular, polonium-210. The device is easy to operate, suitable for use by personnel of any qualification, including at home. ▪ Scintillation detector ▪ Silicon photoelectronic multiplier ▪ High sensitivity ▪ Light and sound indication when registering alpha particles ▪ Long-term operation without recharging ▪ 1" OLED colour screen
Produced in: Belarus, Minsk
Biosafety cabinet BA-Safe 180
Biosafety cabinet BA-Safe 180
The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1830×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1968,5х766,2х1506,6 Height of base, mm 690
Produced in: Belarus, Minsk
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
General characteristics: LCD screen 12.1" with a resolution of 1024 x 768, keyboard, mouse. USB, Ethernet. Supply voltage: 230 V / 50 Hz, power: 450 V·A. Operating temperature range: from +5° to +40°C. Dimensions (W x H x D): 470 x 330 x 570 mm, weight: 37 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
Measurement of the ambient dose equivalent or absorbed dose rate of gamma radiation in liquid media, wells, underground storage facilities and other hard-to-reach places Compatible with detection units: BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-17, BDKG-24, BDKG-30 Measurement at depths up to 30 meters Marking on the cable to determine the depth of immersion A Cable Winding Coil
Produced in: Belarus, Minsk
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
Storage and transfer of kerma units in the air, ambient, individual and directional dose equivalents and their X-ray radiation capacities to working standards and measuring instruments. ▪ The use of highly stable ISOVOLT X-ray machines with metal-ceramic tubes ▪ Field shaper with radiation qualities according to GOST 8.087, ISO 4037, IEC 61267, etc. ▪ Replaceable discs with 11 filter slots; 3 replaceable diaphragms ▪ Additional filters up to 50 mm thick ▪ A protective flap made of tungsten with beam attenuation of more than 1000 times and a response time of less than 0.1 s ▪ A camera monitor and an electrometric unit provide monitoring of the presence and stability of the radiation output ▪ A positioning system in the radiation beam along three axes ▪ A laser detector centering devices ▪ A video surveillance system of indications ▪ Alarm and blocking systems, radiation monitoring ▪ A control system using operator panels and PC
Produced in: Belarus, Minsk
Universal calibrator H4-201
Universal calibrator H4-201
Technical specifications: reproduction of DC voltage from 50 mv to 1000 V - ranges of 200 mV; 2; 20; 200; 1000 V - error 0.01 – 0.023 % reproduction of the sinusoidal AC voltage from 0.3 mV to 750 V - ranges of 200 mV; 2; 20; 200; 750 V - error 0.15 – 0.225 % - frequency range 20 Hz - 100 kHz (20 Hz - 5 kHz on the range. 200 V; 20 Hz - 2.5 kHz on the range. 750 V) reproduction of DC power from 0.03 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.012 – 0.022 % reproduction of AC power of sinusoidal shape from 3 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.062 – 0.23 % - frequency range 20 - 5000 Hz (45 - 1000 Hz on the range. 50 A) RS-232C interfaces; USB operating temperature range from + 5 to +40oC dimensions 184.5x465x540.5 mm weight 20 kg power supply ~ 230 V
MNIPI
Minsk
Produced in: Belarus, Minsk
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software Mobility and the possibility to organize the control of passages in a short time High reliability and self-control Backup power supply
Produced in: Belarus, Minsk
RADIOMETER RKS‑AT1329
RADIOMETER RKS‑AT1329
The radiometer allows you to: - measure the total alpha and total beta activity of counting samples based on aerosol analytical filters of the AFA type; - measure the total alpha and total beta activity of "thick-layer" counting samples prepared from the sample substance (for example, by evaporation or by any other method that provides a "thick" sample); - measure the total alpha and total beta activity of "thin-layer" counting samples prepared from the sample substance (for example, by electrolytic deposition); - measure activity, flux density, external alpha and beta radiation for sources of type 1P9, 2P9, 3P9, 1C0, 2C0, 3C0; - control radiation contamination of surfaces by smears. Device control and measurement data processing is performed by an external PC The possibility to use custom calibrations The possibility to select units of measurement LED stabilization of the measuring path Passive lead protection against background radiation The possibility to maintain a measurement database Methodological support of measurements
Produced in: Belarus, Minsk
EPR spectrometer CMS8400 NEO
EPR spectrometer CMS8400 NEO
The CMS8400 NEO is a compact electron paramagnetic resonance spectrometer designed for routine research in physics, chemistry, biology and related scientific fields for direct detection of free radicals and paramagnetic materials. The CMS8400 NEO can be used in both laboratory and industrial settings in the mode of on-line measurements, embedded in technological processes, thus providing control of parameters and reactions in the production process. Additional accessories and adapted software can make the spectrometer an analytical tool and allow to implement new complex applications in medicine, petrochemistry, brewing, sanitary and hygienic control, as well as in other industries.
Produced in: Belarus